Acknowledgement
본 연구는 한국연구재단이 주관하는 가동원전 안전성 향상 핵심기술 개발사업(No. RS-2023-00144425)의 지원을 받아 수행되었습니다.
References
- Ali, A., Abu-Hayah, N., Kim, D., Cho, S.G. (2017) Design Response Spectra-Compliant Real and Synthetic GMS for Seismic Analysis of Seismically Isolated Nuclear Reactor Containment Building, Nucl. Eng. & Technol., 49(4), pp. 825~837. https://doi.org/10.1016/j.net.2017.02.006
- Carne, T.G., Dohrmann, C.R. (1995) A Modal Test Design Strategy for Model Correlation, 13th Int. Modal Analysis Conf., Nashville, Tennessee, USA, pp.927~933.
- Choi, S., Park, S., Hyun, C.H., Kim, M.S. (2013) In-Operation Modal Analysis of Containments using Ambient Vibration, Nucl. Eng. & Des., 260, pp.16~29. https://doi.org/10.1016/j.nucengdes.2013.01.027
- Chu, S.Y., Kang, C.J. (2021) Development of the Structural Health Record of Containment Building in Nuclear Power Plant, Nucl. Eng. & Technol., 53(6), pp.2038~2045. https://doi.org/10.1016/j.net.2020.12.018
- Guo, H.Y., Zhang, L., Zhang, L.L., Zhou, J.X. (2004) Optimal Placement of Sensors for Structural Health Monitoring using Improved Genetic Algorithms, Smart Mater. & Struct., 13(3), p.528.
- Heo, G., Wang , M.L., Satpathi, D. (1997) Optimal Transducer Placement for Health Monitoring of Long Span Bridge, Soil Dyn. & Earthq. Eng., 16(7-8), pp.495~502. https://doi.org/10.1016/S0267-7261(97)00010-9
- Huang, Y., Ludwig, S.A., Deng, F. (2016) Sensor Optimization using a Genetic Algorithm for Structural Health Monitoring in Harsh Environments, J. Civil Struct. Health Monit., 6, pp.509~519. https://doi.org/10.1007/s13349-016-0170-y
- Joe, Y.H., Cho, S.G. (2002) Seismic Fragility Analysis of Multi-Modes Structures Considering Modal Contribution Factor, J. Earthq. Eng. Soc. Korea, 6(4), pp.15~22. https://doi.org/10.5000/EESK.2002.6.4.015
- Kammer, D.C. (1991) Sensor Placement for On-Orbit Modal Identification and Correlation of Large Space Structures, J. Guid., Control & Dyn., 14(2), pp.251~259. https://doi.org/10.2514/3.20635
- Kim, M.G. (2017) Safety of Nuclear Power Plant According to the 912 Gyeongju Earthquake in 2016, KSCE J. Civil Eng., 65(4), pp.31~35.
- Lee, E. T., Eun, H. C. (2022) An Optimal Sensor Layout Using the Frequency Response Function Data within a Wide Range of Frequencies, Sens., 22(10), Nashville, Tennessee, USA, p.3778.
- Makey, G., Yavuz, O., Kesim, D.K., Turnali, A., Elahi, P., Ilday, S., Ilday, F.O. (2019) Breaking Crosstalk Limits to Dynamic Holography using Orthogonality of High-Dimensional Random Vectors, Nat. Photon., 13(4), pp. 251~256. https://doi.org/10.1038/s41566-019-0393-7
- Michel, C., Gueguen, P., Bard, P.Y. (2008) Dynamic Parameters of Structures Extracted from Ambient Vibration Measurements: An Aid for the Seismic Vulnerability Assessment of Existing Buildings in Moderate Seismic Hazard Regions, Soil Dyn. & Earthq. Eng., 28(8), pp.593~604. https://doi.org/10.1016/j.soildyn.2007.10.002
- NSSC (2017) Measures to Improve the Safety of Nuclear Facilities in Preparation for Major Earthquakes, 73, Nuclear Safety and Security Commission.
- NSSC (2018) Seismic Reinforcement Comprehensive Verification Special Committee Operation Result, 77, Nuclear Safety and Security Commission.
- Papadimitriou, C., Beck, J.L., Au, S.K. (2000) Entropy-based Optimal Sensor Location for Structural Model Updating, J. Vib. & Control, 6(5), pp.781~800. https://doi.org/10.1177/107754630000600508
- Park, S.M., Kim, J.H. (2008) Securing Seismic Safety for Nuclear Power Plant in Korea, Mag. Korean Soc. Hazard Mitig., 8(2), pp.25~34.
- Tan, Y., Zhang , L. (2020) Computational Methodologies for Optimal Sensor Placement in Structural Health Monitoring: A Review, Struct. Health Monit., 19(4), pp.1287~1308. https://doi.org/10.1177/1475921719877579
- Yi, T.H., Li, H.N., Gu, M. (2011) Optimal Sensor Placement for Structural Health Monitoring based on Multiple Optimization Strategies, Struct. Des. Tall & Spec. Build., 20(7), pp.881~900. https://doi.org/10.1002/tal.712