DOI QR코드

DOI QR Code

건물의 침기부하 절감을 위한 에너지셔터에 관한 연구

A Study on Energy Shutters to Reduce Infiltration Load of Buildings

  • Gwang Soo Ko (Major of Mechanical Engineering, Jeju National University) ;
  • Youn Cheol Park (Major of Mechanical Engineering, Jeju National University)
  • 투고 : 2023.02.07
  • 심사 : 2023.05.09
  • 발행 : 2023.06.01

초록

In this study, in order to reduce the amount of infiltration generated from windows among the heat loss generated in the building, energy shutters were installed on the windows to conduct experiments on the change in internal temperature and amount of infiltration due to the pressure difference between the environmental chamber and the pressure box. As a result of the experiment, when the pressure difference was 0Pa, the initial temperature of the pressure box of window was higher than that of the pressure box of the energy shutter, but when the pressure difference occurred, the internal temperature of the pressure box of the energy shutter was higher. In addition, the amount of infiltration of the energy shutter was lower than that of the windows in all experimental conditions, and it was concluded that the reduction rate of the infiltration load (of the energy shutters) could be reduced by 53.3% compared to that of the windows.

키워드

과제정보

이 논문은 2022학년도 제주대학교 교원성과지원사업에 의하여 연구되었음.

참고문헌

  1. Ministry of Construction and Transportation, 2008, Notification No. 2008-5 of Ministry of Construction and Transportation.
  2. Hwang, D. S. and Lee, K. H., 2011, A Study on the Change of Indoor Thermal Environment According to the location of Building, Journal of the korean Solar Energy Society., Vol. 31, No. 5, pp. 113-118. https://doi.org/10.7836/KSES.2011.31.5.113
  3. Jang, C. Y. and Lee, N. E., 2010, A Measurement and Evaluation of Air Tightness of temperable Low-e Windows, Proceedings of SAREK, pp. 368-371.
  4. Kim, S. S., Cho, S., Yoon, Y. J., and Park, H. S., 2005, The study on the Determining of the Infiltration Coefficient by Window Types, Journal of Architectural Institute of Korea of Planning and Design, Vol. 21, No. 4, pp. 183-189.
  5. Chung, J. M., 2012, A study on the Development of the Door Hardwares Construction Specification for Safety and Quality Improvement of Building Door, MS thesis, Seoul National University of Science and Technology.
  6. Moon, S. D., Chung, J. M., and Ock, J. H., 2013, Analysis of the Causes of Defects in Fenestration Construction and Their Impacts on Construction Quality, Journal of the Korea Institute of Building Construction, Vol. 13, No. 4, pp. 341-350. https://doi.org/10.5345/JKIBC.2013.13.4.341
  7. Yun, Y. N., Park, J. J., Kim, Y. I., and Chung, K. S., 2016, An Experimental Study of Window Air Tightness according to Filling Piece Shapes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 28, No. 2, pp. 63-68. https://doi.org/10.6110/KJACR.2016.28.2.063
  8. Mehmet, A.A., Orhan, B., and Tuncay, Y., 2010, A case study for inflence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions, Applied Energy, Vol. 87, pp. 599-607. https://doi.org/10.1016/j.apenergy.2009.05.008
  9. Steven, J. E. and Andrew, K.P., 1998, Energy impact of infilteration and ventilation in U.S. office building using multizon airflow simulation, IAQ and Energy, pp. 191-196.
  10. Choi, J. M. and Cho, S. W., 2012, A Study on Relationship Insulation Thickness and Infiltration Load by Window. Vol. 24, No. 5, pp. 422-427. https://doi.org/10.6110/KJACR.2012.24.5.422