Performance Evaluation of Steel Frame and Steel Damper Reinforced in RC frame

RC 골조에 보강된 강재프레임과 강재댐퍼의 성능 평가

  • Lee, Hyun-Ho (Dept. of Architecture & Fire Safety, Dongyang University)
  • 이현호 (동양대학교 건축소방안전학과)
  • Received : 2023.01.30
  • Accepted : 2023.03.02
  • Published : 2023.03.15

Abstract

In this study, the performance evaluation of the RC frame specimen (RV2) which was strengthened by a steel frame and a steel damper with the lateral deformation prevention details proceeded. The comparison objects are bare frame specimen (BF), RV2 and AWD, where AWD is a specimen reinforced with steel damper and aramid fiber sheets. In the evaluation of envelope curve, stiffness degradation, and energy dissipation capacity, RV2 was evaluated to have excellent capacity as a whole. To evaluate the strengthening effect of the steel frame based on the maximum strength and energy dissipation capacity, it was evaluated to have a 38% of the RV2's capacity.

Keywords

Acknowledgement

이 논문은 2022년도 동양대학교 학술연구비의 지원으로 수행되었음

References

  1. Lee, J. H., Park, B. T., and Km, Y. S., "Experimental structural performance evaluation of hybrid damper combining with high damping rubber and steel slit", Journal of the Korean Association for Spatial Structures, Vol.22, No.4, pp.23~30, 2022, doi:10.9712/KASS.2022.22.4.23
  2. Architectural Institute of Korea, "Seismic Building Design Code and Commentary : KDS 41 17 00", pp.136~139, 2019.
  3. Ministry of Education, "Seismic Performance Evaluation and Reinforcement Manual for School Facilities", pp.97, 2021.
  4. Yoo, C. G., & Choi C. S., "An experimental study on seismic performance of two-story reinforced concrete frames retrofitted with internal steel frame and wall type friction damper", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.26, No.6, pp.64~72, 2022, doi: 10.11112/jksmi.2022.26.6.64
  5. Lee, H. H,. "The effect of preventing lateral deformation of the clamp type steel damper in rocking behavior ", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.25, No.5, pp.141~148, 2021, doi: 10.11112/jksmi.2021.25.5.141
  6. Lee, H. H., "Capacity development of existing frame by aramid sheet and energy dissipation device", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.19, No.5, pp.112-119, 2015, doi: 10.11112/jksmi.2015.19.5.112
  7. Lee, H. H., "Hysteretic behavior of steel damper for the lateral displacement control", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.22, No.3, pp.46-52, 2018, doi: 10.11112/jksmi.2018.22.3.046