DOI QR코드

DOI QR Code

Seismic Performance of Alternative Steel Structural Systems for an Equipment-Supporting Plant Structure

플랜트 설비 지지용 대안 강구조 시스템의 내진성능

  • Kwak, Byeong Hun (Department of Architecture, Incheon National University) ;
  • Ahn, Sook-Jin (Department of Architecture, Incheon National University) ;
  • Park, Ji-Hun (Division of Architecture and Urban Design, Incheon National University)
  • 곽병훈 (인천대학교 일반대학원 건축학과) ;
  • 안숙진 (인천대학교 일반대학원 건축학과) ;
  • 박지훈 (인천대학교 도시건축학부)
  • Received : 2022.10.20
  • Accepted : 2022.11.18
  • Published : 2023.01.01

Abstract

In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.

Keywords

Acknowledgement

본 연구는 국토교통부/국토교통과학기술진흥원의 지원으로 수행되었음(과제번호 22RMPP-C163162-02)

References

  1. KDS 41 17 00. Seismic Building Design Code. Korea Construction Standards Center. c2019.
  2. Kwak BH, Park JH, Ahn SJ. Comparison of Seismic Performance and Material Quantity between Code-based and Performance-based Seismic Design of a Equipment-Supporting Plant Structure. 2022. In EESK Workshop, p.21-22.
  3. Oh SH, Kim YH, Ryu HS, Kim YJ, Park HY. Experimental verification of seismic performance of built-up beam-to-column connections with ductile detail. Journal of Consturctional Steel Research. 2021 Jan;176. Article 106397.
  4. Kim SH, Lee SH, Kim JH, Kim DJ, Choi SM. An Experimental Study on the Hysteresis Behavior of WUF-B Beam-Column Connection using SN steel. Journal of Korean Society of Steel Construction. 2008;20(6):807-815.
  5. Oh SH, Choi YJ, Yoon SK, Lee DG. Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN steel. Journal of Korean Society of Steel Construction. 2010;22(3):271-280.
  6. KDS 41 31 00. Korean Building Code for Steel Structures. Korea Construction Standards Center. c2019.
  7. Kim SY, Shin CH. Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength. Journal of Korean Society of Hazard Mitigation. 2007 Mar;7(1):11-20.
  8. Lee CH, Kim JH. Effects of PZ Strength on Cyclic Seismic Performance of RBS Steel Moment Connections. EESK J. Earthquake Eng. 2006 Jun;10(3):149-158. https://doi.org/10.5000/EESK.2006.10.3.149
  9. A. Moslehi Tabar, A. Deylami. Instability of beams with reduced beam section moment connections emphasizing the effect of column panel zone ductility. Journal of Constructional Steel Research. 2005 Nov;61(11):1475-1491. https://doi.org/10.1016/j.jcsr.2005.05.006
  10. American Society of Civil Engineers. ASCE 41-17 Seismic Evalution and Retrofitting Techniques for Unreinforced Masonry Buildings. c2017.
  11. National Institute of Standards and Technology. Recommended modeling parameters and acceptance criteria for nonlinear analysis in support of seismic evaluation, retrofit, and design. NIST GCR 17-917-45, Gaithersburg, MD. c2017.
  12. Han SW, Kwon GU. Seismic Performance Evaluation of WUF-B Connections Part 1. Experimental Investigation. Journal of Architectural Institute of Korea. 2003 Nov;19(11):33-40.
  13. Lee CH, Kwon KT, Jung JH, Oh MH, Koo ES. Cyclic Seismic Testing of Steel Moment Connections Reinforced with Welded Straight Haunch. EESK J. Earthquake Eng. 2002 Aug;6(4):31-37. https://doi.org/10.1080/13632460209350409
  14. National Institute of Standards and Technology. Evaluation of the FEMA P-695 Methodology for Quantification of Building Seismic Performance Factors. c2010.