DOI QR코드

DOI QR Code

구강안면 근긴장이상을 가진 완전 무치악 환자에서 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복

Maxillary complete denture with posterior zirconia occlusion and mandibular implant support fixed prostheses in completely edentulous patients with orofacial dystonia

  • 서종민 (부산대학교 치의학전문대학원 치과보철학교실, 치의생명과학연구소) ;
  • 정창모 (부산대학교 치의학전문대학원 치과보철학교실, 치의생명과학연구소) ;
  • 이소현 (부산대학교 치의학전문대학원 치과보철학교실, 치의생명과학연구소)
  • Jong-Min Seo (Department of Prosthodontics, Dental and Life Sciences Institute, Education and Resea) ;
  • Chang-Mo Jeong (Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University) ;
  • So-Hyoun Lee (Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National Universityrch Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
  • 투고 : 2023.10.16
  • 심사 : 2023.10.24
  • 발행 : 2023.12.31

초록

구강안면 근긴장이상(Orofacial dystonia)은 자신의 의지와 상관없이 불수의적으로 얼굴, 입술, 혀 및 턱 주변을 불규칙적이거나 반복적으로 움직이는 신경운동학적 장애로 틱장애로 불리기도 한다. 이러한 증상을 갖는 무치악 환자는 총의치 사용의 어려움과 더불어 언어 장애 및 연하곤란, 구강안면의 통증까지 기능적이고 심미적인 문제점들을 겪게 된다. 본 증례에서는 비교적 젊은 나이에 완전 무치악 상태를 경험하게 된 구강안면 근긴장이상 환자를 위해, 양측 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복치료를 시행하고 지속적인 미소훈련을 시행하여 안면근육의 심미적인 개선을 도모하고자 하였다. 치료의 결과, 환자는 저작기능과 심미성이 향상된 것 뿐만 아니라, 심리적 안정감을 회복하여 정상적인 일상생활이 가능해진 것에 대해 매우 만족하였기에 이를 보고하고자 한다.

Orofacial dystonia is a neuromotor disorder that causes irregular or repetitive movements of the face, lips, tongue, and jaw involuntarily, also called tic disorder. Edentulous patients with these symptoms experience functional and aesthetic problems, including difficulty using complete dentures, speech and swallowing difficulties, and orofacial pain. In this case, for a patient with orofacial dystonia who experienced complete edentulism at a relatively young age, restorative treatment was performed with a maxillary complete denture with bilateral posterior zirconia occlusal surfaces and a mandibular implant-supported fixed prosthesis, and continuous smile training was performed. The aim was to improve the aesthetics of facial muscles. As a result of the treatment, the patient was very satisfied with not only improved chewing function and aesthetics, but also regained psychological stability and was able to lead a normal daily life, so we would like to report this.

키워드

과제정보

This work was supported by a 2-Year Research Grant of Pusan National University.

참고문헌

  1. Kai HL. Oromandibular dystonia. Oral Surg Oral Med Oral Pathol Oral Radio Endod 2007;104:491-6. https://doi.org/10.1016/j.tripleo.2007.04.001
  2. Blanchet PJ, Rompre PH, Lavigne GJ, Lamarche C. Oral dyskinesia: a clinical overview. Int J Prosthodont 2005;18:10-9.
  3. Lumetti S, Ghiacci G, Macaluso GM, Amore M, Galli C, Calciolari E, Manfredi E. Tardive dyskinesia, oral parafunction, and implant-supported rehabilitation. Case Rep Dent 2016;2016:7167452.
  4. Singh RK, Kundra S, Rani S. A prevalence based evaluation of etiology and site of fracture of acrylic resin dentures: a survey based original study. J Adv Med Dent Sci Res 2017;5:11-4.
  5. Wallace DH. The use of gold occlusal surfaces in complete and partial dentures. J Prosthet Dent 1964;14:326-33. https://doi.org/10.1016/0022-3913(64)90093-9
  6. Balasubramaniam R, Ram S. Orofacial movement disorders. Oral Maxillofac Surg Clin North Am 2008;20:273-85. https://doi.org/10.1016/j.coms.2007.12.010
  7. Chee W, Jivraj S. Treatment planning of the edentulous mandible. Br Dent J 2006;201:337-47. https://doi.org/10.1038/sj.bdj.4814041
  8. Radke UM, Gundawar SM, Banarjee RS, Paldiwal AS. The single complete denture - a case report. Int J Clin Dent Sci 2012;3:76-81.
  9. Prachi G, Jyotsna S, Maya D, Milind K. Metal reinforced single complete denture - a case report. Int J Med Oral Res 2018;3:38-40.
  10. Diaz-Arnold AM, Vargas MA, Shaull KL, Laffoon JE, Qian F. Flexural and fatigue strengths of denture base resin. J Prosthet Dent 2008;100:47-51. https://doi.org/10.1016/S0022-3913(08)60136-5
  11. Upadhyay SR, Singh SV, Bhalla G, Kumar L, Singh BP. Modified functionally generated path technique for single complete denture against non-modified natural dentition. J Oral Biol Craniofac Res 2012;2:67-71. https://doi.org/10.1016/S2212-4268(12)60016-5
  12. Hu F, Pei Z, Wen Y. Using intraoral scanning technology for three-dimensional printing of Kennedy Class I removable partial denture metal framework: a clinical report. J Prosthodont 2019;28:e473-6. https://doi.org/10.1111/jopr.12712
  13. McGuire MK, Nunn ME. Prognosis versus actual outcome. II. The effectiveness of clinical parameters in developing an accurate prognosis. J Periodontol 1996;67:658-65. https://doi.org/10.1902/jop.1996.67.7.658
  14. Ortorp A, Jonsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with 4 different techniques: a comparative in vitro study. Dent Mater J 2011;27:356-63. https://doi.org/10.1016/j.dental.2010.11.015
  15. Cabianca M. Combination sydrome: treatment with dental implants. Implant Dent 2003;12:300-5. https://doi.org/10.1097/01.ID.0000094033.62974.BB
  16. Chong BJ, Thangavel AK, Rolton SB, Guazzato M, Klineberg IJ. Clinical and laboratory surface finishing procedures for zirconia on opposing human enamel wear: a laboratory study. J Mech Behav Biomed Mater 2015;50:93-103. https://doi.org/10.1016/j.jmbbm.2015.06.007
  17. Ghazal M, Kern M. The influence of antagonistic surface roughness on the wear of human enamel and nanofilled composite resin artificial teeth. J Prosthet Dent 2009;101:342-9. https://doi.org/10.1016/S0022-3913(09)60068-8
  18. Ghazal M, Yang B, Ludwig K, Kern M. Two-body wear of resin and ceramic denture teeth in comparison to human enamel. Dent Mater 2008;24:502-7. https://doi.org/10.1016/j.dental.2007.04.012
  19. Shori K, Shori T, Shori D, Chavan R. Achieving esthetic perfection by zirconia: A Case Report. Int J Dent Med Res 2015;1:146-9.
  20. Lawson NC, Janyavula S, Syklawer S, Mclaren EA, Burgess JO. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing. J Dent 2014;42:1586-91. https://doi.org/10.1016/j.jdent.2014.09.008
  21. Lambert H, Durand JC, Jacquot B, Fages M. Dental biomaterials for chairside CAD-CAM: State of the art. J Adv Prosthodont 2017;9:486-95. https://doi.org/10.4047/jap.2017.9.6.486
  22. Gibson RM. Smiling and Facial Exercise. Dent Clin North Am 1989;33:139-44. https://doi.org/10.1016/S0011-8532(22)01182-X