DOI QR코드

DOI QR Code

Study on the Testing Method for Moisture Permeability of Packaging Containers according to the Amount of Desiccant

흡습제 투입량에 따른 포장용기의 투습도 시험 방법 고찰

  • 김도영 (국방기술품질원 품질연구본부) ;
  • 노예은 (국방기술품질원 품질연구본부) ;
  • 김경민 (국방기술품질원 품질연구본부) ;
  • 장지민 (육군 탄약지원사령부)
  • Received : 2023.09.09
  • Accepted : 2023.11.06
  • Published : 2023.12.31

Abstract

In the field of ammunition, storage performance is recognized as important, and the moisture-proof performance of packaging containers is very important. In the ammunition field, paper cans with a multi-layered structure are mainly used as packaging containers. It is made by layering materials that play various roles. These packaging containers are mainly evaluated for moisture-proof performance according to the Korean Industrial Standard KS T 1314. The moisture permeability is determined through linear regression analysis of the change in weight of the moisture absorbent added inside. In this study, the effect of the amount of desiccant added on the moisture permeability test results of packaging containers was confirmed. It is considered appropriate that the amount of desiccant used in testing ammunition packaging containers be approximately 70% or more of the internal volume.

저장성능이 중요하게 인식되는 탄약분야에 있어서 포장용기의 방습성능은 크게 강조되어 왔다. 탄약분야에서는 주로 다중 적층구조를 갖는 지환통이 포장용기로 사용되고 있는데, 이는 다양한 역할을 하는 재료를 적층하여 만들어진다. 이러한 포장용기는 주로 한국산업규격 KS T 1314에 따라 방습성능을 평가하게 되며, 내부에 투입된 흡습제의 무게 변화에 대하여 선형 회귀분석을 통하여 투습도가 결정된다. 본 연구에서는 흡습제 투입량이 포장용기의 투습도 시험 결과에 미치는 영향을 확인하였다. 탄약 포장용기로 사용되는 지환통의 평가 시, 사용되는 흡습제의 양은 내부 용적의 약 70 % 이상이 타당한 것으로 판단된다.

Keywords

References

  1. Baskerville, G. L. (1972). Use of logarithmic regression in the estimation of plant biomass. Canadian Journal of Forest Research, 2(1), 49-53. https://doi.org/10.1139/x72-009
  2. Beirlant, J., Dierckx, G., Goegebeur, Y., & Matthys, G. (1999). Tail index estimation and an exponential regression model. Extremes, 2, 177-200. https://doi.org/10.1023/A:1009975020370
  3. Carapic, J., Deschambault, E. J., Holtom, P., & King, B. (2018). A Practical Guide to Life-cycle Management of Ammunition. Geneva: Small Arms Survey.
  4. Draper, J. V., Lam, Y. H., Khanna, V., & OAK RIDGE NATIONAL LAB TN. (1993). Comparisons of Fiber Tube Ammunition Container Variants for Moisture Permeability and Absorption.
  5. Kim. M. S., Park. J. S., and Ahn. B. C., (2009). A Method for the Analysis of the Radiowave Receiving Characteristics of the Electric Detonator. Journal of the Korea Industrial Information Systems Research, 14(1), 9-16.
  6. Sumimoto, M. (2012). Paper and paperboard containers. Academic Press. 53-83
  7. Wilkinson, A. (2006). Stockpile Management of Ammunition. Targeting Ammunition: A Primer. Geneva: Small Arms Survey, 228-59.