DOI QR코드

DOI QR Code

A design study of a 4.7 T 85 mm low temperature superconductor magnet for a nuclear magnetic resonance spectrometer

  • Bae, Ryunjun (Department of Electrical and Computer Engineering, Seoul National University) ;
  • Lee, Jung Tae (Department of Electrical and Computer Engineering, Seoul National University) ;
  • Park, Jeonghwan (Department of Electrical and Computer Engineering, Seoul National University) ;
  • Choi, Kibum (Department of Electrical and Computer Engineering, Seoul National University) ;
  • Hahn, Seungyong (Department of Electrical and Computer Engineering, Seoul National University)
  • Received : 2021.11.19
  • Accepted : 2022.08.27
  • Published : 2022.09.30

Abstract

One of the recent proposals with nuclear magnetic resonance (NMR) is a multi-bore NMR which consists of array of magnets which could present possibilities to quickly cope with pandemic virus by multiple inspection of virus samples. Low temperature superconductor (LTS) can be a candidate for mass production of the magnet due to its low price in fabrication as well as operation by applying the helium zero boil-off technology. However, training feature of LTS magnet still hinders the low cost operation due to multiple boil-offs during premature quenches. Thus in this paper, LTS magnet with low mechanical stress is designed targeting the "training-free" LTS magnet for mass production of magnet array for multi-bore NMR. A thorough process of an LTS magnet design is conducted, including the analyses as the followings: electromagnetics, mechanical stress, cryogenics, stability, and protection. The magnet specification was set to 4.7 T in a winding bore of 85 mm, corresponding to the MR frequency of 200 MHz. The stress level is tolerable with respect to the wire yield strength and epoxy crack where mechanical disturbance is less than the minimum quench energy.

Keywords

Acknowledgement

This work was supported by National R&D Program through the National Research Foundation of Korea(NRF) funded by Ministry of Science and ICT(2022M3I9A1072846). This work was also supported in part by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety) (1711138068, Project Number: KMDF_PR_20200901_0063).

References

  1. J. Bascunan, S. Hahn, Y. Kim, J. Song and Y. Iwasa, "90-mm/18.8- T All-HTS Insert Magnet for 1.3 GHz LTS/HTS NMR Application: Magnet Design and Double-Pancake Coil Fabrication," in IEEE Transactions on Applied Superconductivity, vol. 24, no. 3, pp. 1-4, June 2014, Art no. 4300904.
  2. M. Guan et al., "A Parametric Study on Overband Radial Build for a REBCO 800-MHz Insert of a 1.3-GHz LTS/HTS NMR Magnet," in IEEE Transactions on Applied Superconductivity, vol. 26, no. 4, pp. 1-5, June 2016, Art no. 4301205.
  3. S. Hahn, J. Bascunan, W. Yao, and Y. Iwasa, "Two hts options for a 600 mhz insert of a 1.3 ghz lts/hts nmr magnet: Ybco and bscco," Physica C: Superconductivity and its applications, vol. 470, no. 20, pp. 1721-1726, 2010. https://doi.org/10.1016/j.physc.2010.05.194
  4. Piao, R., S. Iguchi, M. Hamada, S. Matsumoto, H. Suematsu, A. T. Saito, J. Li et al. "High resolution NMR measurements using a 400 MHz NMR with an (RE) Ba2Cu3O7- x high-temperature superconducting inner coil: Towards a compact super-high-field NMR." Journal of Magnetic Resonance 263 (2016): 164-171. https://doi.org/10.1016/j.jmr.2015.11.015
  5. Luchinat, Enrico, et al. "Protein in-cell NMR spectroscopy at 1.2 GHz." Journal of biomolecular NMR, vol. 75, no. 2, pp. 97-107, 2021. https://doi.org/10.1007/s10858-021-00358-w
  6. Y. Li, L. Wang and Q. Wang, "Electromagnetic Design of HTS Insert for Ultrahigh Field NMR Magnet," in IEEE Transactions on Applied Superconductivity, vol. 28, no. 3, pp. 1-5, April 2018, Art no. 4602105.
  7. K. L. Kim et al., "400-MHz/60-mm All-REBCO Nuclear Magnetic Resonance Magnet: Magnet Design," in IEEE Transactions on Applied Superconductivity, vol. 26, no. 4, pp. 1-4, June 2016, Art no. 4302604.
  8. Jeonghwan Park et al., "Electromagnetic Analysis of HTS Magnet Array," presented in 2022 Winter KIASC [O LA-II 1].
  9. Siemens Healthineers. Translate 7T Research Power Into Clinical Care with MAGNETOM Terra [Brochure], 2018.
  10. M. N. Wilson, Superconducting Magnets. New York: Oxford University Press Inc., 1983, p. 89.
  11. Y. Li et al., "Analysis of Damage by Quench and Improvements in Rewinding for a 9.4-T Superconducting NMR Magnet," in IEEE Transactions on Applied Superconductivity, vol. 26, no. 1, pp. 1-5, Jan. 2016, Art no. 4300105.
  12. W. Gray and C. Sun, "Theoretical and experimental determination of mechanical properties of superconducting composite wire," OAK RIDGENATIONAL LAB TN, Tech. Rep., 1976.
  13. Guan, Mingzhi, Xingzhe Wang, and Youhe Zhou. "Effects of coldtreatment and strain-rate on mechanical properties of NbTi/Cu superconducting composite wires." SpringerPlus, vol. 4, no. 1, pp. 1-7, 2015. https://doi.org/10.1186/2193-1801-4-1
  14. J. Ekin, "Mechanisms for critical-current degradation in NbTi and Nb3Sn multifilamentary wires," in IEEE Transactions on Magnetics, vol. 13, no. 1, pp. 127-130, January 1977. https://doi.org/10.1109/TMAG.1977.1059371
  15. Y. Iwasa, Case studies in superconducting magnets: design and operational issues. Springer science & business media, 2009.
  16. K. Seo and M. Morita, "Guidelines for LTS magnet design based on transient stability," Cryogenics, vol. 45, no. 5, pp. 354-361, 2006.