Acknowledgement
이 논문은 2020년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업임(No. 2020R1A6A1A03045059).
References
- Boennec, O., 2008, Shallow ground energy systems, Proceedings of the Institution of Civil Engineers-Energy, Vol. 161, No. 2, pp. 57-61. https://doi.org/10.1680/ener.2008.161.2.57
- Lee, C., Park, S., Won, J., Jeoung, J., Sohn, B., and Choi, H., 2012, Evaluation of thermal performance of energy textile installed in Tunnel, Renewable Energy, Vol. 42, pp. 11-22. https://doi.org/10.1016/j.renene.2011.09.031
- Park, S., Lee, S., Sung, C., and Choi, H., 2021, Applicability evaluation of cast-in-place energy piles based on two-year heating and cooling operation, Renewable and Sustainable Energy Reviews, Vol. 143, 110906. https://doi.org/10.1016/j.rser.2021.110906
- Lee, S., Park, S., Won, J., and Choi, H., 2021, Influential factors on thermal performance of energy slabs equipped with an insulation layer, Renewable Energy, Vol. 174, pp. 823-834. https://doi.org/10.1016/j.renene.2021.04.090
- Hamada, Y., Saitoh, H., Nakamura, M., Kubota, H., and Ochifuji, K., 2007, Field performance of an energy pile system for space heating, Energy and Buildings, Vol. 39, No. 5, pp. 517-524. https://doi.org/10.1016/j.enbuild.2006.09.006
- Miyara, A., Tsubaki, K., Inoue, S., and Yoshida, K., 2011, Experimental study of several types of ground heat exchanger using a steel pile foundation, Renewable Energy, Vol. 36, No. 2, pp. 764-771. https://doi.org/10.1016/j.renene.2010.08.011
- Park, S., Lee, D., Choi, H. J., Jung, K., and Choi, H., 2015, Relative constructability and thermal performance of cast-in-place concrete energy pile: Coil-type GHEX (ground heat exchanger), Energy, Vol. 81, pp. 56-66. https://doi.org/10.1016/j.energy.2014.08.012
- Park, S., Lee, S., Oh, K., Kim, D., and Choi, H., 2018, Engineering chart for thermal performance of cast-inplace energy pile considering thermal resistance, Applied Thermal Engineering, Vol. 130, pp. 899-921. https://doi.org/10.1016/j.applthermaleng.2017.11.065
- Park, S., Lee, S., Lee, D., Ahn, D., and Choi, H., 2019, Effect of thermal interference on energy piles considering various configurations of heat exchangers, Energy and Buildings, Vol. 199, pp. 381-401. https://doi.org/10.1016/j.enbuild.2019.07.008
- Kim, M., 2021, Evaluation of applicability of steel tubes as replacements of steel bars for reinforcement of drilled shafts, PhD Thesis, Hanyang University.
- ASTM, 1995, Standard test method for determination of thermal conductivity of soil and soft rock by needle probe procedure, D 5334.
- Lee, H. S., Cha, Y. T., Jang, H. S., Lee, Y. H., Kim, J. G., Shin. D. Y., Choi, S. J., and Lee, S. S., 2015, A design method of casing rotator for all casing method, Proceedings of the The Korea Fluid Power Systems Society Conference, The Korea Fluid Power Systems Society, pp. 59-62.
- Wood, C. J., Liu, H., and Riffat, S. B., 2012, Comparative performance of 'U-tube' and 'coaxial' loop designs for use with a ground source heat pump, Applied Thermal Engineering, Vol. 37, pp. 190-195. https://doi.org/10.1016/j.applthermaleng.2011.11.015
- Oh, K., Lee, S., Park, S., Han, S. I., and Choi, H., 2019, Field experiment on heat exchange performance of various coaxial-type ground heat exchangers considering construction conditions, Renewable Energy, Vol. 144, pp. 84-96. https://doi.org/10.1016/j.renene.2018.10.078