Acknowledgement
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government(MSIT) (No.2021M2D1A1039965).
References
- F.K. Manasse, J.J. Pinajian, A.N. Tse, Schottky barrier betavoltaic battery, IEEE Trans. Nucl. Sci. 23 (1976) 860-870. https://doi.org/10.1109/TNS.1976.4328356
- G.H. Miley, Direct Conversion of Nuclear Radiation Energy, U.I.U.C., 1970. No. TID-25672.
- H. Guo, A. Lal, Nanopower betavoltaic microbatteries, in: In TRANSDUCERS'03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No. 03TH8664) 1, IEEE Press, 2003.
- A. Krasnov, S. Legotin, K. Kuzmina, N. Ershova, A nuclear battery based on silicon p-i-n structures with electroplating 63Ni layer, Nucl. Eng. Technol. 51 (2019) 1978-1982. https://doi.org/10.1016/j.net.2019.06.003
- M.V.S. Chandrashekhar, I.T. Christopher, H. Li, M.G. Spencer, A. Lal, Demonstration of a 4H SiC betavoltaic cell, Appl. Phys. Lett. 88 (2006), https://doi.org/10.1063/1.2166699.
- G.C. Messenger, A summary review of displacement damage from high energy radiation in silicon semiconductors and semiconductor devices, IEEE Trans. Nucl. Sci. 39 (1992) 468-473. https://doi.org/10.1109/23.277547
- G.P. Summers, E.A. Burke, P. Shapiro, S.R. Messenger, R.J. Walters, Damage correlations in semiconductors exposed to gamma, electron and proton radiations, IEEE Trans. Nucl. Sci. 40 (1993) 1372-1379. https://doi.org/10.1109/23.273529
- J.E. Turner, Atoms, Radiation, and Radiation Protection, third ed., Wiley-VCH, Weinheim, 2012.
- H. Kang, S. Min, B. Seo, C. Roh, S. Hong, J.H. Cheong, Low energy beta emitter measurement: a review, Chemosensors (2020), https://doi.org/10.3390/chemosensors8040106.
- J. Borg, Dosimetry of low-energy beta radiation, Risoe Natl. Lab. (1996). No. RISO-Rd907.
- J.J. Kim, Y.R. Uhm, K.J. Son, Fabrication of 63Ni layer for betavoltaic battery, in: Proceedings of the 15th IEEE International Conference on Nanotechnology, Rome, Italy, July 27-30, 2015.
- J.J. Kim, S.M. Choi, K.J. Son, J.T. Hong, Development of small-scale electroplating system for Ni-63 electroplating onto Ni foil, in: Transactions of the Korean Nuclear Society Autumn Meeting, Gyeongju, Korea, October 27-28, 2016.
- Y.R. Uhm, B.G. Choi, J.B. Kim, D.H. Jeong, K.J. Son, Study of a betavoltaic battery using electroplated nickel-63 on nickel foil as a power source, Nucl. Eng. Technol. 48 (2016) 773-777. https://doi.org/10.1016/j.net.2016.01.010
- J.J. Kim, S.M. Choi, G.J. Son, J.T. Hong, Manufacturing of Ni-63 sealed source for betavoltaic battery using the small-scale electroplating device, J. Radiat. Ind. 11 (2017) 173-179.
- W. Ji, J.B. Kim, Development of rapid beta detector using PIN diode to be used in quality control of Ni-63 beta-voltaic battery, J. Radioanal. Nucl. Chem. 330 (2021) 245-252. https://doi.org/10.1007/s10967-021-07933-3
- W.R. Wampler, B.L. Doyle, Low-energy beta spectroscopy using pin diodes to monitor tritium surface contamination, Nucl. Instrum. Methods Phys. Res.: Accel. Spectrom. Detect. Assoc. Equip. 349 (1994) 473-480. https://doi.org/10.1016/0168-9002(94)91213-0
- R.S. Willms, D. Dogruel, R. Myers, R. Farrell, A new solid state tritium surface monitor, Fusion Sci. Technol. 48 (2005) 409-412. https://doi.org/10.13182/FST05-A955
- M.J. Butson, K.N. Peter, T. Cheung, P. Metcalfe, Radiochromic film for medical radiation dosimetry, Mat. Sci. Eng. R. 41 (2003) 61-120. https://doi.org/10.1016/S0927-796X(03)00034-2
- D. Slobodan, Radiochromic film dosimetry: past, present, and future, Phys. Med. 27 (2010) 122-134.
- D. Slobodan, N. Tomic, L. David, Reference radiochromic film dosimetry: review of technical aspects, Phys. Med. 32 (2016) 541-556. https://doi.org/10.1016/j.ejmp.2016.02.008
- B. Mukherjee, Y.H. Gholami, U. Bhonsle, R. Hentschel, J. Khachan, A unique alpha dosimetry technique using Gafchromic EBT3® film and feasibility study for an activity calibrator for alpha-emitting radiopharmaceuticals, Br. J. Radiol. 88 (2015), https://doi.org/10.1259/brj.20150035.
- K.H. Lee, J.Y. Shin, E.H. Kim, Measurement of activity distribution in an Am241 disc source using peeled-off Gafchromic EBT3 films, Appl. Radiat. Isot. 135 (2018) 192-200. https://doi.org/10.1016/j.apradiso.2018.01.037
- C.Y.P. Ng, S.L. Chun, K.N. Yu, Quality assurance of alpha-particle dosimetry using peeled-off Gafchromic EBT3® film, Radiat. Phys. Chem. 125 (2016) 176-179. https://doi.org/10.1016/j.radphyschem.2016.04.014
- G. Massillon-Jl, C.T. Sou-Tung, I. Doming-Munoz, M.F. Chan, Energy dependence of the new Gafchromic EBT3 film: dose response curves for 50 kV, 6, and 15 MV X-ray Beams, I, J. Med. Phys. Clin. Eng. Radiat. Oncol. 1 (2012) 60-65. https://doi.org/10.4236/ijmpcero.2012.12008
- A. Rink, I.A. Vitkin, D.A. Jaffray, Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real time optical dosimeter, Med. Phys. 34 (2007) 458-463. https://doi.org/10.1118/1.2431425
- K. Duruer, D. Etiz, H. Yucel, Investigation of EBT3 radiochromic film response in a high-dose range of 6MV photon and 6 MeV electron beams using a threecolor flatbed scanner, East. Eur. J. Phys. 3 (2020) 11-18.
- B.C. Ferreira, M.C. Lopes, M. Capela, Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry, Phys. Med. Biol. 54 (2009) 1073. https://doi.org/10.1088/0031-9155/54/4/017