Abstract
In this study, we investigated the operation data of combined heat and power in accordance with the change of the inlet guide vane with partial load. The partial load 80% could close the inlet guide vane up to 24%, and the exhaust gas temperature could be increased by 52℃. The partial load 90% could close the inlet guide vane up to 12%, and the exhaust gas temperature could be increased by 23℃. At 80% of partial load with the thermal load tracking mode, the output could be increased up to 5.68 MW, the combined cycle efficiency increased by 0.73%, and the combined heat and power efficiency increased by 1.81%. At 90% of the partial load, the output could be increased up to 2.55 MW, the combined cycle efficiency increased by 0.32%, and the combined heat and power efficiency increased by 0.72%.
본 연구에서는 부분부하 운전 시 가스터빈의 공기량 조절에 따른 열병합 발전의 운전데이터 변화를 알아보았다. 가스터빈 부분부하 80%시 시뮬레이션 한 결과 입구가이드베인을 최대 24% 추가로 닫을 수 있었고, 압축기 공기량은 66.11 kg/s 감소, 배기가스 온도는 52℃ 상승시킬 수 있었다. 부분부하 90%는 입구가이드베인을 최대 12% 추가로 닫을 수 있었고, 압축기 공기량은 33.33 kg/s 감소, 배기가스 온도는 23℃ 상승 시킬 수 있었다. 열부하 추종운전 시 부분 부하 80%에서 출력을 최대 5.68 MW 상승, 복합발전 효율을 0.73% 상승, 열병합발전 효율을 1.81% 상승 시킬 수 있었고, 부분부하 90%에서 출력을 최대 2.55 MW 상승, 복합발전 효율을 0.32% 상승, 열병합발전 효율을 0.72% 상승 시킬 수 있었다.