Dynamic rod worth measurement method based on eqilibrium-kinetics status

  • Lee, Eun-Ki (Korea Hydro and Nuclear Power Co., Ltd. Central Research Institute (KHNP CRI)) ;
  • Jo, YuGwon (Korea Hydro and Nuclear Power Co., Ltd. Central Research Institute (KHNP CRI)) ;
  • Lee, Hwan-Soo (Korea Hydro and Nuclear Power Co., Ltd. Central Research Institute (KHNP CRI))
  • 투고 : 2021.06.22
  • 심사 : 2021.08.27
  • 발행 : 2022.03.25

초록

KHNP had licensed Dynamic Control rod Reactivity Measurement (DCRM) method using detector current signals of PWRs in 2006. The method has been applied to all PWRs in Korea for about 15 years successfully. However, the original method was inapplicable to PWRs using low-sensitivity integral fission chamber as ex-core detectors because of their pulse pile-up and the nonlinearity of the mean-square voltage at low power region. Therefore, to overcome this disadvantage, a modified method, DCRM-EK, was developed using kinetics behavior after equilibrium condition where the pulse counts maintain the maximum value before pulse pile-up. Overall measurement, analysis procedure, and related computer codes were changed slightly to reflect the site test condition. The new method was applied to a total of 15 control rods of 1000 MWe and 1400 MWe PWRs in Korea with worths in the range of 200 pcm -1200 pcm. The results show the average difference of -0.4% and the maximum difference of 7.1% compared to the design values. Therefore, the new DCRM-EK will be applied to PWRs using low sensitivity integral fission chambers, and also can replace the original DCRM when the evaluation fails by big noises present in current or voltage signals of uncompensated/compensated ion chambers.

키워드

참고문헌

  1. E.K. Lee, et al., "Application of the Dynamic Control Rod Reactivity Measurement Method to Korea Standard Nuclear Power Plants," PHYSOR 2004 (Physics and Fuel Cycles and Advanced Nuclear Systems:Global Developments), 2004. Chicago, Illinois, April 25-29, Jan.
  2. E.K. Lee, et al., "New dynamic method to measure rod worths in zero power physics test at PWR startup," pp1457-1475, Ann. Nucl. Energy 32 (13) (2005). Sep. https://doi.org/10.1016/j.anucene.2005.04.008
  3. D.F. Kastanya, I. Ariani, P.J. Turinsky, Verification of dynamic rod worth measurement calculational methodology, Advances in Nuclear Fuel Management II, Myrtle Beach, ANS 14-65 (1997).
  4. Y.A. Chao, D.M. Chapman, D.J. Hill, L.R. Grobmyer, "Dynamic rod worth measurement,", Nucl. Tech. 132 (2000) 403. https://doi.org/10.13182/nt00-a3153
  5. D.H. Park, et al., "Calibration method of liquid zone controller using the excore detector signal of CANDU-6 reactor," pp209-217, Ann. Nucl. Energy 54 (2013). April. https://doi.org/10.1016/j.anucene.2012.11.021
  6. E.K. Lee, et al., "Evaluation of the applicable reactivity range of A reactivity computer for A CANDU-6 reactor," pp183-194, Nuclear Eng. Tech. 46 (2) (2014). April. https://doi.org/10.5516/NET.01.2013.026
  7. S.G. Hong, J.S. Song, A preliminary simulation study of dynamic rod worth for the SMART reactor, Ann. Nucl. Energy 60 (2013) 350-356. https://doi.org/10.1016/j.anucene.2013.05.014
  8. N.R. Campbell, V.J. Fransis, A theory of valve and circuit noise, J. Inst. Eng. Electron. 93 (3) (1946).
  9. G.F. Knoll, Radiation Detection and Measurement, second ed., John Wiley & Sons, New York, 2000.
  10. DOORS3.2a: One, Tow- and Three- Dimensional Discrete Ordinates Transport Code System, CCC-650, RSICC, Oak Ridge national Lab, 2003.
  11. E.K. Lee, et al., A performance test of non-linear NEM/ANM CMFD in LWR core Transient,, in: Proceedings of the KNS-KARP Joint Spring Meeting, May 23, Gwangju, Korea, 2002.
  12. Y.S. Liu, et al., "ANC, A Westinghouse Advanced Nodal Computer Code, WCAP-11596-P-A, 1986.
  13. ANSI/ANS-19.6.1-2005, "Reload Startup Physics Tests for PWRs, American Nuclear Society, 2005.