DOI QR코드

DOI QR Code

Wind Effects on Tall Buildings with a Porous Double-Skin Façade

  • Shengyu Tian (School of Civil and Environmental Engineering, Harbin Institute of Technology) ;
  • Cassandra Brigden (School of Civil Engineering, The University of Sydney) ;
  • Caroline Kingsford (School of Civil Engineering, The University of Sydney) ;
  • Gang Hu (School of Civil and Environmental Engineering, Harbin Institute of Technology) ;
  • Robert Ong (School of Civil Engineering, The University of Sydney) ;
  • K.C.S. Kwok (School of Civil Engineering, The University of Sydney)
  • 발행 : 2022.12.01

초록

Double-Skin Facades (DSF) on tall buildings are becoming increasingly common in urban environments due to their ability to provide architectural merit, passive design, acoustic control and even improved structural efficiency. This study aims to understand the effects of porous DSF on the aerodynamic characteristics of tall buildings using wind tunnel tests. High Frequency Force Balance and pressure tests were performed on the CAARC standard tall building model with a variable porous DSF on the windward face. The introduction of a porous DSF did not adversely affect the overall mean forces and moments experienced by the building, with few differences compared to the standard tall building model. There was also minimal variation between the results for the three porosities tested: 50%, 65% and 80%. The presence of a full-height porous DSF was shown to effectively reduce the mean and fluctuating wind pressure on the side face of the building by about 10%, and a porous DSF over the lower half height of the building was almost as effective. This indicates that the porous DSF could be used to reduce the design load on cladding and fixtures on the side faces of tall buildings, where most damage to facades typically occurs.

키워드

참고문헌

  1. Ayed, S. B., Ragab, S. A., & Haji, M. R. (2016). Flow control of extreme pressure loads associated with flow separation. Journal of Engineering Mechanics, 142, 04015068.
  2. Azad, A, Samali, B, Ngo, T & Nguyen, C 2013, 'Dynamic behaviour of flexible facade systems in tall buildings subjected to wind loads', in Samali, B, Attard, MM & Song, C (eds.), From Materials to Structures: Advancement through Innovation, CRC Press, United Kingdom.
  3. Belloli, M, Rosa, L & Zasso, A 2014, 'Wind loads and vortex shedding analysis on the effects of the porosity on a high slender tower', Journal of Wind Engineering and Industrial Aerodynamics, vol. 126, pp. 75-86. https://doi.org/10.1016/j.jweia.2014.01.004
  4. Chan, ALS, Chow, TT, Fong, KF & Lin, Z 2009, 'Investigation on energy performance of double skin facade in Hong Kong', Energy and Buildings, vol. 41, no. 11, pp. 1135-1142. https://doi.org/10.1016/j.enbuild.2009.05.012
  5. Cook, N. J. (1982). Calibration of the quasi-static and peakfactor approaches to the assessment of wind loads against the method of Cook and Mayne. Journal of Wind Engineering and Industrial Aerodynamics, 10(3), 315-341. https://doi.org/10.1016/0167-6105(82)90005
  6. Davenport, A. G. (2007). Wind Tunnel Testing: A General Outline. The University of Western Ontario, Faculty of Engineering Science. London, Ontario, Canada.
  7. Ding, W, Hasemi, Y & Yamada, T 2005, 'Natural ventilation performance of a double-skin facade with a solar chimney', Energy and Buildings, vol. 37, pp. 411-418. https://doi.org/10.1016/j.enbuild.2004.08.002
  8. Feldmann, FKM 2012, 'Wind Loads for Permeable Cladding Elements with High Porosity', The 2012 World Congress on Advances in Civil, Environmental, and Materials Research, Seoul, Korea.
  9. Gerhardt, HJ & Janser, F 1994, 'Wind loads on wind permeable facades', Journal of Wind Engineering and Industrial Aerodynamics, vol. 53, no. 1, pp. 37-48. https://doi.org/10.1016/0167-6105(94)90017-5
  10. Grabe, JV 2002, 'A prediction tool for the temperature field of double facades', Energy and Buildings, vol. 34, pp. 891-899. https://doi.org/10.1016/S0378-7788(02)00065-8
  11. Gratia, E., & De Herde, A. (2004). Natural cooling strategies efficiency in an office building with a double-skin facade. Energy and Buildings, 36(11), 1139-1152. https://doi.org/10.1016/j.enbuild. 2004.05.004
  12. Haver & Boecker. (n.d.). Montes Urales 125, Mexico. Retrieved from https://www.weavingarchitecture.com/fileadmin/contents/Referenzen/Montes_Urales_Mexico/PDF/Montes_Urales_Mexico.pdf
  13. Hu, G, Hassanli, S, Kwok, KCS & Tse, KT 2017, 'Windinduced responses of a tall building with a double-skin facade system', Journal of Wind Engineering and Industrial Aerodynamics, vol. 168, pp. 91-100. https://doi.org/10.1016/j.jweia.2017.05.008
  14. Lou, W, Huang, M, Zhang, M & Lin, N 2012, 'Experimental and zonal modeling for wind pressures on double-skin facades of a tall building', Energy and Buildings, vol. 54, pp. 179-191. https://doi.org/10.1016/j.enbuild.2012.06.025
  15. Marques Da Silva, F & Gloria Gomes, M 2008, 'Gap inner pressures in multi-storey double skin facades', Energy and Buildings, vol. 40, no. 8, pp. 1553-1559. https://doi.org/10.1016/j.enbuild.2008.02.014
  16. Pipitone, G, Barone, G & Palmeri, A 2018, 'Optimal design of double?skin facades as vibration absorbers', Structural Control and Health Monitoring, vol. 25, no. 2, pp. e2086.
  17. Shameri, MA, Alghoul, MA, Sopian, K, Zain, MFM & Elayeb, O 2011, 'Perspectives of double skin facade systems in buildings and energy saving', Renewable and Sustainable Energy Reviews, vol. 15, no. 3, pp. 1468-1475. https://doi.org/10.1016/j.rser.2010.10.016
  18. Sinclair, R, Phillips, D & Mezhibovski, V 2009, 'Ventilating Facades', ASHRAE Journal, vol. 51, no. 4, pp. 16-27.
  19. Standards Australia, & Standards New Zealand. (2011). Structural design actions. Part 2: Wind actions (AS/NZS 1170.2:2011). Sydney, N.S.W.; Wellington [N.Z.: Jointly published by SAI Global under licence from Standards Australia; Standards New Zealand.
  20. Zhang, M, Lou, W-J & Chen, Y 2008, 'Wind pressure distribution and gust factor on double-skin facades of high-rise building with rectangular shape', Journal of Zheliang Universitym (Engineering Science), vol. 42, pp. 54-59.
  21. Zheng, C & Zhang, Y 2010, 'Numerical investigation of wind-load reduction for a high-rise building by blowing control', J. Build. Struct, vol. 31, no. 2, pp. S176-S181.