DOI QR코드

DOI QR Code

Development of usability evaluation index of convergence technology remote fluid monitoring device for non-face-to-face patient nursing system application and analysis of results

비대면 환자 간호시스템 적용을 위한 융합기술의 원격 수액모니터링 장치 사용성평가 지표 개발 및 결과 분석

  • Kim, Seon-Chil (Department of Biomedical Engineering, School of Medicine, Keimyung University)
  • 김선칠 (계명대학교 의용공학과)
  • Received : 2022.03.16
  • Accepted : 2022.04.20
  • Published : 2022.04.28

Abstract

The usability evaluation of the remote fluid monitoring device, which was introduced to reduce the work of nurses and increase the efficiency, was performed due to the expansion of the non-face-to-face medical system. Remote fluid monitoring is a fusion of various technologies such as fluid measurement and analysis, error correction technology, and transmission technology. The range of use by users, the information they want to obtain, and the control device, etc. are wide, and the factors that evaluate the product are also diverse. Therefore, it is difficult to improve the product through evaluation. In this study, a quantitative index was developed to help improve the product for commercialization by conducting 20 usability evaluations in three areas of product stability, operability, and satisfaction with the remote sap monitoring system device. It was performed through infrared and load cell-type sap monitoring devices. In terms of stability, there was a difference in installation work such as fixing the pole of the device, and high satisfaction was shown for operability and accuracy. In terms of product satisfaction, the satisfaction of load cell devices was generally high.

비대면 의료시스템의 확대로 간호사의 업무 경감 및 효율성을 높이기 위해서 도입되는 원격수액모니터링 장치의 사용성평가를 수행하였다. 원격 수액 모니터링은 수액 측정시술과 분석, 오차 교정기술, 전송기술 등 다양한 기술이 융복합되어 있다. 사용자가 사용하는 범위와 얻고자 하는 정보, 조절 장치 등 사용범위가 넓으며 제품을 평가하는 요소도 다양하다. 따라서 평가를 통해 제품을 개선하는데 어려움이 있다. 본 연구에서는 원격수액모니터링 시스템장치를 제품의 안정성, 조작성, 만족도의 3개 영역에서 20개의 사용성평가를 실시하여 상용화를 위한 제품개선에 도움을 주고자 정량적인 지표를 개발하였다. 적외선 방식과 로드셀 방식의 수액모니터링 장치를 통해 수행하였으며, 안정성에서는 장치의 폴대고정 등 설치작업에 대해 차이가 있었으며, 조작성과 정확성에 대해서는 높은 만족도를 나타내었다. 제품의 만족도에서는 로드셀 장치의 만족도가 대체로 높게 나타났다.

Keywords

Acknowledgement

This work was supported by project for Collabo R&D between Industry, Academy, and Research Institute funded by Korea Ministry of SMEs and Startups in 2021.(Project No. S3088856).

References

  1. S. Y. Oh & D. H. Kym. (2020), Serum Lactate, Creatinine and Urine Output: Early Predictors of Mortality after Initial Fluid Resuscitation in Severe Burn Patients, 20.0008, Journal of Korean Burn Society, 23-(1), 1-6. DOI : 10.47955/jkbs.20.0008
  2. Y. N. Kim. (2022). The Influence Factors on Nursing Work Performance by Clinical Nurses, Journal of the Korea Academia-Industrial cooperation Society 23, 594-602. DOI : 10.5762/KAIS.2022.23.1.594
  3. S. J. Bai, J. W. Lee & K. Y. Lee (2010), Fluid therapy: classification and characteristics of intravenous fluids, J Korean Med Assoc 2010 December, 53(12), 1103-1112. DOI : 10.5124/jkma.2010.53.12.1103
  4. J. H. Park & S. K. Chung. (2016). Influence of Emotional Labor, Communication Competence and Resilience on Nursing Performance in University Hospital Nurses, Journal of the Korea Academia-Industrial cooperation Society, 17(10), 236-244. DOI : 10.5762/KAIS.2016.17.10.236
  5. H. M. Lee & Y. H. Pan. (2019). The Medical Supplies KIT Design based on the Intravenous Fluid Therapy for Experience of Medical Staff, Journal of the Korea Convergence Society, 10(8), 121-128. DOI : 10.15207/JKCS.2019.10.8.121
  6. J. S. Choi & J. S. Kim. (2013). Nurses' Perception, Knowledge, and it's Affecting Factors on Performance of Nursing Practice in Hospital with No Guardian. The Korea Contents Association, All Rights Reserved, 13(10), 403. DOI : 10.5392/JKCA.2013.13.10.403
  7. J. H. Park. (2020). Adaptation of VR 360-degree Intravenous Infusion Educational Content for Nursing Students. 165-170, The Journal of the Convergence on Culture Technology, 6(4), 165-170. DOI : 10.17703/JCCT.2020.6.4.165
  8. Rolf Molich, Meghan R Ede, klaus kaasgaard & Barbara Katyukin (2007), Comparative usability evaluation, Behaviour & Information Technology, 23(2004). DOI : 10.1080/014492903200017395
  9. S. H. Moon, B. G. Kang, J. J. An, H. K. Jo, H. R. Yoo, I. C. Seol & Y. S. Kim. (2008). Study of the Indicators of Each Pattern Identification Based on Korean Standard Differentiation of the Symptoms and Signs for Stroke, Korean J. Oriental Physiology & Pathology, 22(2), 487-496.
  10. D. H. Jang & S. K. Cho. (2017). Is the Mid-point of a Likert-type Scale Necessary?: Comparison between the Scales With or Without the Mid-point, The Korean Assosiation For Survey Research, 17(4), 1-24. DOI : 10.20997/SR.18.4.1
  11. C. H. Lawshe. (1975). A quantitative approach to content validity. Personnel Psychology, 28(4), 563-575. DOI : 10.1111/j.1744-6570.1975.tb01393.x
  12. J. Nielsen & T. K. Landauer. (1993). A mathematical model of the finding of usability problems. Proceedings of the Interact '93 & Chi '93 Conference: Human Factors in Computing Systems, 5(1), 206-213. DOI : 10.1145/169059.169166
  13. B. Sullivan. (2000). Designing Web Usability: The Practice of Simplicity. Technical Communication, 47(3), 411-413. DOI : 10.1145/169059.169166
  14. L. J. Cronbach. (1949). Essentials of Psychological Testing. 5th ed. New York : Harper e Brothers.
  15. Y. H. So. (2016), A Comparison Analysis of Usability Evaluation for Simulation Learning based on Web 3D and Virtual Reality The Journal of the Korea Contents Association, 16(10), 719-729. DOI : 10.5392/JKCA.2016.16.10.719
  16. J. S. Yoo, B. S. Kim. (2016), Development of Usability Assessment Indicator of Adjustable Electric Beds for Home Care, Journal of the Korea Safety Management & Science 18(1). DOI : 10.12812/ksms.2016.18.1.45
  17. J. S. Kim & S. H. Han. (2008). A methodology for developing a usability index of consumer electronic products. Int J Ind Ergon, 38(3-4), 333-345. DOI : 10.1016/j.ergon.2007.12.002
  18. N. Jakob & M. Rolf. (1990). Heuristic evaluation of user interfaces. ACM CHZ'90, 249-256. DOI : 10.1145/97243.97281
  19. B. C. Kwakl & K. W. Kim. (2021). Design Improvement Direction of ICT Convergence Products through Usability Evaluation, Journal of Cultural Product & Design, 67, 141-154. DOI : 10.18555/kicpd.2021.67.013
  20. E. J. Sin, J. B. Song & S. B. Lim. (2021). Development of Evaluation Indicators and Analysis of Usability on Learning with a Robot for the Elderly - the case of Content using the Humanoid Robot 'LiKU' DOI : 10.5392/JKCA.2021.21.11.056