DOI QR코드

DOI QR Code

Simulation Study for a UV Water Disinfection Unit Powered by a Photovoltaic System

  • Riahi, Said (UR-LAPER, Faculty of Sciences of Tunis University of Tunis El Manar) ;
  • Mami, Abdelkader (UR-LAPER, Faculty of Sciences of Tunis University of Tunis El Manar) ;
  • Minzu, Viorel (Control and Electrical Engineering Department,"Dunarea de Jos" University)
  • 투고 : 2021.12.05
  • 발행 : 2022.01.30

초록

This work presents a simulation model for a specific UV disinfection system (UVDS) powered by a Photovoltaic System. The global UVDS also includes the electronic converters, Electronic Ballast, UV Lamp and Motor Pump. The equations that model the physical components' behaviour are connected to obtain a dynamic global model. The latter is converted in a Simulink/Matlab model, which allows to carry out simulation series concerning the entire UVDS. The physical parameters: the irradiation G and the temperature T, are considered as inputs. series of measurements carried out in order to show how these parameters affect the current, the voltage of the PVs and especially the value of the current of the UV lamp, on the other hand a study on the behavior and the evolution of the parameters of the motor pump such as the armature current, motor torque, speed of rotation and the water flow. The purpose of all this is to realize how important are the two parameters concerning the lamp current and the water flow because they are two very important factors to keep an adequate water quality.

키워드

참고문헌

  1. S. Sharma and A Bhattacharya, "Drinking water contamination and treatment techniques", Appl. Water Sci. 2017, 7, 1043-1067. https://doi.org/10.1007/s13201-016-0455-7
  2. K. Ouelhazi, A. Ben Chaabene, A. i Sellam, and A. Hassen, "Multivariable model of an ultraviolet water disinfection system 67(2017)89-96," Desalination and Water Treatment, vol. 67, pp. 89-96, 2017. https://doi.org/10.5004/dwt.2017.20451
  3. V. Minzu, S. Riahi, and E. Rusu, "Optimal Control of an Ultraviolet Water Disinfection System," Applied Sciences, vol. 11, no.6, p. 2638, Mar. 2021. https://doi.org/10.3390/app11062638
  4. W. Artichowicz, A. Luczkiewicz and J.M. Sawicki, "Analysis of the Radiation Dose in UV-Disinfection Flow Reactors," Water, 12, 231, 2020. https://doi.org/10.3390/w12010231
  5. B. Mounaouer and H. Abdennaceur, "Disinfection of Water by UV Irradiation-Modeling and Improvement," Current Biotechnologye, vol. 1, no. 3, pp. 199-206, Jul. 2012. https://doi.org/10.2174/2211550111201030199
  6. P. Herrick, "Mathematical models for high-intensity discharge lamps", IEEE Transaction on Industry Applications, IA16(5):648-654, 1980 https://doi.org/10.1109/TIA.1980.4503847
  7. T. Messai, A. Chammam, A. Sellami, "Conductivity Polynomial Model Parameters identification based on Particle Swarm Optimization", Control Eng. and Applied Informatics, Vol.15, no 4, p. 58-65, 2013.
  8. X.H. Nguyen and M.P. Nguyen, "Mathematical modeling of photovoltaic cell/module/arrays with tags in Matlab/Simulink," Environmental Systems Research, vol. 4, no. 1, 2015.
  9. J. Hahm, J. Baek, H. Kang, H. Lee, and M. Park," Matlab-Based Modeling and Simulations to Study the Performance of Different MPPT Techniques used for Photovoltaic Systems under Partially Shaded Conditions", International Journal of Photoenergy, Article ID 979267, vol. 2015.
  10. S. D. Al-Majidi, M. F. Abbod, and H. S. Al-Raweshidy, "A novel maximum power point tracking technique based on fuzzy logic for photovoltaic systems," Int. J. of Hydrogen Energy, vol. 43, no. 31, p.14158-14171, 2018. https://doi.org/10.1016/j.ijhydene.2018.06.002
  11. M. Clerc, L'optimisation par Essaims Particulaires -Versions Parametriques et Adaptatives, Hermes, Lavoisier, Paris, 2005.
  12. N. Zitouni, R.Andoulsi, A.Sellami,A.Mami,and A.Hassen," A new Bond Graph Model of a Water Disinfection System Based on UV Lamp Feed by Photovoltaic Source : Simulation and Experimental Results," J.Automat.sys.Eng.5:79-95,2011.
  13. N. Zitouni, R. Andoulsi, A. Sellami, A. Mami,and A. Hassen," Sliding-Mode Control for an artificial neural network Analysis and Design of treatment water system, J.Electrical system, vol.7,no.2,pp.237-257,2011.
  14. M. Ben Said, M. Ben Mustapha, and A. Hassen, "The impact of power supply frequency of a low pressure UV lamp on bacterial viability and activities," Desalination and Water Treatment, pp. 1-7, Nov. 2013.
  15. C. Blanco et al., "A Discharge Lamp Model Based on Lamp Dynamic Conductance," IEEE Transactions on Power Electronics, vol. 22, no. 3, pp. 727-734, May 2007. https://doi.org/10.1109/TPEL.2007.897195
  16. A. Bokhtache, A. Zegaoui, M. Aillerie, A.Djahbar, and K. Hemici,"Development and optimization of a matrix converter supplying an electronic ballast - UV lamp system for water sterilization," TMREES18-Spring Meeting Technologies and Materials for Renewable Energy, Environment and Sustainability, Feb 2018, Beirut, Lebanon. 1968, pp.30058 - 30058, 2018.
  17. R. H. G. Tan, C. K. Er, and S. G. Solanki, "Modeling of Photovoltaic MPPT Lead Acid Battery Charge Controller for Standalone System Applications," E3S Web of Conferences, vol. 182, no. E3S Web Conf. Volume 182, 2020 2020 10th International Conference on Power, Energy and Electrical Engineering (CPEEE 2020), p. 03005, 2020.
  18. A. A. Paidalwar,and I. P. Khedikar," Overview of Water Disinfection by UV Technology - A Review," IJSTE - International Journal of Science Technology & Engineering,vol.2,Issue 09,March,2016.