DOI QR코드

DOI QR Code

Parametric study of shear capacity of beams having GFRP reinforcement

  • Vora, Tarak P. (Department of Civil Engineering, Marwadi University) ;
  • Shah, Bharat J. (Government Engineering College)
  • Received : 2020.06.03
  • Accepted : 2022.02.18
  • Published : 2022.02.25

Abstract

A wide range of experimental bases and improved performance with different forms of Fiber Reinforced Polymer (FRP) have attracted researchers to produce eco-friendly and sustainable structures. The reinforced concrete (RC) beam's shear capacity has remained a complex phenomenon because of various parameters affecting. Design recommendations for the shear capacity of RC elements having FRP reinforcement need a more experimental database to improve design recommendations because almost all the recommendations replace different parameters with FRP's. Steel and FRP are fundamentally different materials. One is ductile and isotropic, whereas the other is brittle and orthotropic. This paper presents experimental results of the investigation on the beams with glass fiber reinforced polymer (GFRP) reinforcement as longitudinal bars and stirrups. Total twelve beams with GFRP reinforcement were prepared and tested. The cross-section of the beams was rectangular of size 230 × 300 mm, and the total length was 2000 mm with a span of 1800 mm. The beams are designed for simply-supported conditions with the two-point load as per specified load positions for different beams. Flexural reinforcement provided is for the balanced conditions as the beams were supposed to test for shear. Two main variables, such as shear span and spacing of stirrups, were incorporated. The beams were designed as per American Concrete Institute (ACI) ACI 440.1R-15. Relation of VExp./VPred. is derived with axial stiffness, span to depth ratio, and stirrups spacing, from which it is observed that current design provisions provide overestimation, particularly at lower stirrups spacing.

Keywords

References

  1. Ahmed, H. and Abdel, K. (2014), "Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites", Adv. Concrete Constr., 2(4), 281-300. https://doi.org/10.12989/acc.2014.2.4.281.
  2. Al-Tamimi, A., Abed, F.H. and Al-Rahmani, A. (2014), "Effects of harsh environmental exposures on the bond capacity between concrete and GFRP reinforcing bars", Adv. Concrete Constr., 2(1), 1-11. https://doi.org/10.12989/acc.2014.2.1.001.
  3. Alam, M.S., and Hussein, A. (2013). "Unified shear design equation for concrete members reinforced with fiber-reinforced polymer without stirrups", J. Compos. Constr., 17(5), 575-583. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000342.
  4. Altin, S., Anil, O. and Kara, M.E. (2011), "Retrofitting of shear damaged RC beams using CFRP strips", Steel Compos. Struct., 11(3), 207-223. https://doi.org/10.1177/0731684411421843.
  5. ACI (2015), Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars, ACI 440.1R-15, Farmington Hills, MI 48331.
  6. ASCE-ACI Committee 445 on Shear and Torsion (1998), "Recent approaches to shear design of structures", J. Struct. Eng, 1375-1417. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:12(1375).
  7. Canadian Standards Association (CSA) (2006), Canadian Highway Bridge Design Code, CSA S6-06, Toronto.
  8. Canadian Standards Association (CSA) (2012), Design and Construction of Buildings Components with Fiber-Reinforced Polymers, CSA S806-12, Toronto.
  9. Chen, M. and Das, S. (2009), "Experimental study on repair of corroded steel beam using CFRP", Steel Compos. Struct., 9(2), 103-118. https://doi.org/10.12989/scs.2009.9.2.103.
  10. Deitz, D.H., Harik, I.E. and Gesund, H. (1999), "One-way slabs reinforced with glass fiber reinforced polymer reinforcing bars", Spec. Pub., 188, 279-286.
  11. Ehab, A., Ahmed, Ehab, El-Salakawy, F. and Brahim, B. (2010), "Shear performance of RC bridge girders reinforced with carbon FRP stirrups", J. Bridge Eng., 15(1), 44-54. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000035.
  12. El-Sayed, A.K., El-Salakawy, E. and Benmokrane, B. (2007), "Mechanical and structural characterization of new carbon FRP stirrups for concrete members", J. Compos. Constr., 11(4), 352-362. https://doi.org/10.1061/(ASCE)1090-0268(2007)11:4(352)
  13. Guadagnini, M., Pilakoutas, K. and Waldron, P. (2006), "Shear resistance of FRP RC beams: Experimental study", J. Compos. Constr., 10(6), 464-473. https://doi.org/10.1061/(ASCE)1090-0268(2006)10:6(464).
  14. Mesbah, H.A. and Benzaid, R. (2017), "Damage-based stress-strain model of RC cylinders wrapped with CFRP composites, Adv. Concrete Constr., 5(5), 539-561. https://doi.org/10.12989/acc.2017.5.5.539.
  15. Institution of Structural Engineers (1999), "Interim guidance on the design of reinforced concrete structures using fibre composite reinforcement", SETO, London, UK.
  16. Intelligent Sensing for Innovative Structures (2007), "Reinforcing concrete structures with fiber reinforced polymers", ISIS Canada, University of Winnipeg, Winnipeg, MB, Canada.
  17. International Federation for Structural Concrete (fib) (2007), FRP Reinforcement in RC Structures, Bull. 40, CEB-FIP, Lausanne, Switzerland.
  18. Japan Society of Civil Engineering (JSCE) (1997), Recommendation for Design and Construction of Concrete Structures Using Continuous Fiber Reinforcing Materials, Tokyo.
  19. Kilpatrick, A.E. and Dawborn, R. (2006), "Flexural shear capacity of high strength concrete slabs reinforced with longitudinal GFRP bars", FIB, Naples, Italy.
  20. Matta, F., Nanni, A., Hernandez, T.M. and Benmokrane, B. (2008), "Scaling of strength of FRP reinforced concrete beams without shear reinforcement", CICE2008, Zurich, Switzerland.
  21. Michaluk, C.R., Rizkalla, S.H., Tadros, G. and Benmokrane, B. (1998), "Flexural behavior of one-way slabs reinforced by fiber reinforced plastic reinforcement", ACI Struct. J., 95(3), 353-364.
  22. Panda, K.C., Bhattacharyya, S.K. and Barai, S.V. (2013), "Shear strengthening effect by bonded GFRP strips and transverse steel on RC T-beams", Struct. Eng. Mech., 47(1), 75-98. https://doi.org/10.12989/sem.2013.47.1.075.
  23. Razaqpur, A.G., Isgor, B.O., Greenaway, S. and Selley, A. (2004), "Concrete contribution to the shear resistance of fiber reinforced polymer reinforced concrete members", J. Compos. Constr., 8(5), 452-460. https://doi.org/10.1061/ASCE.1090-0268.2004.8:5,
  24. Razaqpur, A.G. and Saverio, S. (2014), "Shear Strength of FRP reinforced concrete members with stirrups", J. Compos. Constr., 19(1), 04014025. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000483, 04014025-(1-15).
  25. Ghomia, S.K. and El-Salakawy, E. (2020), "Effect of geometrical configuration on seismic behavior of GFRP-RC beam-column joints", Adv. Concrete Constr., 9(3), 313-326. https://doi.org/10.12989/acc.2020.9.3.313.
  26. Tureyen, A.K. and Frosch, R.J. (2003), "Concrete shear strength: Another perspective", ACI Struct. J., 100(5), 609-615.
  27. Yost, J.R., Gross, S.P. and Dinehart, D.W. (2001), "Shear strength of normal strength concrete beams reinforced with deformed GFRP bars", J. Compos. Constr., 5(4), 268-275. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:4(268)