DOI QR코드

DOI QR Code

Systematic Review on the efficiency of prefilled syringe : To administer medication for cardiac arrest patient

  • Yoon, Byoung Gil (Dept. of Emergenct Medical Service Konyang University) ;
  • Park, Jung Hee (Dept. of Emergenct Medical Service Konyang University) ;
  • Kim, Young Seo (Dept. of Emergenct Medical Service Konyang University)
  • Received : 2022.11.19
  • Accepted : 2022.12.09
  • Published : 2022.12.31

Abstract

The Pulpose of this systematic review is aimed to establish the procedure of the injection with saftey and efficiency in the pre-hospital cardiac arrest patient performing the cardiopulmonary resuscitation (CPR), compared with traditional medication administration using Ampoule and medication administration with Prefilled Syringe. Databases were searched for CPR, heart arrest, resuscitation, Pre-filled Syringe, and Ampoule by the electronic data research including Pubmed, EMBASE and Cochran Library of Konyang University Library: 4 articles were selected by three co-authors using EndNote X20 and Covidence (Covidence.org) and were systematically reviewed. The Result of this study, the medication administration using Pre-fillled Syringe improves the safety of patients and Emergency medical workers by reducing the error in administration dose and administering the drug in safe than the medication adminisrtaion using Ampoule, also, contributes to the increment of survival rate of cardiac arrest and severe patients by decreasing the administration time that prevents the delay of medication administration.

Keywords

References

  1. I. G. Jacobs, J, C. Finn, G. A. Jelinek, H. F. Oxer, P. L. Thompson. Effect of adrenaline on survival in out-of-hospital cardiac arrest: A randomised double-blind placebo-controlled trial. Resuscitation. Vol. 82, No. 9, 1138-43, 2011 https://doi.org/10.1016/j.resuscitation.2011.06.029
  2. S. Petrou, N. Stallard, S. Gates, R. Lall, For the PARAMEDIC2 Collaborators. A Randomized Trial of Epinephrine in Out-of-Hospital Cardiac Arrest. N Engl J Med. Vol. 379, No. 8, 711-21, 2018. https://doi.org/10.1056/NEJMoa1806842
  3. P. J. Kudenchuk, S. P. Brown, M. Daya, T. Rea, G. Nichol, L. J. Morrison, et al. Amiodarone, lidocaine, or placebo in out-of-hospital cardiac arrest. N Engl J Med. Vol. 375, 1711-22, 2016.
  4. P. J. Kudenchuk, M. Daya, P. Dorian. Resuscitation outcomes consortium I. Amiodarone, lidocaine, or placebo in out-of-hospital cardiac arrest. N Engl J Med. Vol. 375, 802-3, 2016.
  5. P. J. Kudenchuk, L. A. Cobb, M. K. Copass, R. O. Cummins, A. M. Doherty, C. E. Fahrenbruch, et al. Amiodarone for resuscitation after out-of-hospital cardiac arrest due to ventricular fibrillation. N Engl J  Med. Vol. 341, 871-8, 1999. https://doi.org/10.1056/NEJM199909163411203
  6. H. h, OH, K. C. Cha, J. H. Lee, D. H. Kim, B. K. Lee, J. S. Park. et al. 2020 Korean Guidelines for Cardiopulmonary Resuscitation. Part 4. Adult advanced life support. Clin Exp Emerg Med. Vol. 8, No. S, 26-40, 2021.
  7. Korean Council of Professors for Emergency Medical Service. Management of Emergency Patient 5th edition. Seoul: Daehakseorim, 338-355.
  8. Ministry of Food and Drug Safety. Available at: https://nedrug.mfds.go.kr/index
  9. M.H. Murad, NIV. Asi, M. Alsawas, F. Alahdab. "New evidence Pyramid", Evid Based Med. Vol. 21, No. 4, 125-127, 2016. http://dx.doi.org/10.1136/ebmed-2016-110447
  10. N.Castle, J. Bowen, N. Spencer, Does wearing CBRN-PPE adversely affect the ability for clinicians to accurately, safely, and speedily draw up drugs? Clin Toxicol (Phila). Vol. 48, No. 6, 522-527, 2010. DOI:10.3109/15563650.2010.491483
  11. R. M. Adapa, V. Mani, L. J. Murray, B. A. Degnan, A. Ercole, B. Cadman et.al, Errors during the preparation of drug infusions: a randomized controlled trial. British Journal of Anesthesia. Vol. 109, No. 5, 729-34, 2012. doi:10.1093/bja/aes257
  12. A. D. Stevens, C. Hernandez, S. Jones, M. E. Moreira, J. R. Blumen, E. Hopkins et.al. Color-coded prefilled medication syringes decrease time to delivery and dosing errors in simulated prehospital pediatric resuscitations: A randomized crossover trial. Resuscitation. Vol. 96, 85-91, 2015. DOI: 10.1016/j.resusci tation.2015.07.035
  13. M. E. Moreira, C. Hernandez, A. D. Stevens, S. Jones, M. Sande, J. R. Blumen, Color-Coded Prefilled Medication Syringes Decrease Time to Delivery and Dosing Error in Simulated Emergency Department Pediatric Resuscitations. Ann Emerg Med. Vol. 66, No. 2, 97-106, 2015. DOI: 10.1016/j.annemergmed.2014.12.035
  14. Korea Disease Control and Prevention Agency. 2020 Korean Guideline for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. 133-148. 2020
  15. D. D. Degnan, T. N. Bullard, M. B. Davis, Risk of Patient Harm Related to Unnecessary Dilution of Ready-to-Administer Prefilled Syringes: A Literature Review. J Infus Nurs, Vol. 43, No. 3, 146-154, 2020. DOI: 10.1097/nan.0000000000000366
  16. A. R. Kafal, D. C. Vinh, M. J. Langelier, Prefilled syringes for immunoglobulin G (IgG) replacement therapy: clinical experience from other disease settings, Expert Opin Drug Deliv, Vol. 15, No. 12, 1199-1209, 2018. DOI: 10.1080/17425247.2018.1546692
  17. Z. Mohanna, S. Kusljic, R. Jarden, Investigation of interventions to reduce nurses' medication errors in adult intensive care units: A systematic review. Aust Crit Care, Vol. 35, No. 4, 466-479, 2021. DOI: 10.1016/j.aucc.2021.05.012
  18. Expert Rev. Vaccine presentation in the USA: economics of prefilled syringes versus multidose vials for influenza vaccination. Vaccines, Vol. 9, No. 11, 1343-1349, 2021. https://doi.org/10.3390/vaccines9111343