Acknowledgement
본 연구는 2018년도 산업통상자원부의 재원으로 한국에너지기술평가원(KETEP)의 원자력핵심기술개발사업의 지원(No. 20181520102780)을 받아 수행한 연구과제입니다.
References
- "When the largest thermal power plant stopped due to an earthquake, the remaining three power plants stopped one after another", The Chosunilbo World. 2018 Sep 7 [Revised, 2018 Sep 12]. Available from: https://www.chosun.com/site/data/html_dir/2018/09/07/2018090700298.html.
- Kunieda M, Chiba T, Kobayashi H. Positive use of damping devices for piping systems-some experiences and new proposals. J Nuclear Engineering Design. 1987;104(2):107-120. https://doi.org/10.1016/0029-5493(87)90292-5
- Olson DE, Tang YK. Decreasing snubber in-service inspection costs through snubber reduction and improved test limits. J Nuclear Engineering Design. 1988;107(1-2):183-199. https://doi.org/10.1016/0029-5493(88)90321-4
- Parulekar YM, Reddy GR, Vaze KK, Kushwaha HS. Elasto-plastic damper for passive control of seismic response of piping systems. BARC Internal Report. Reactor Safety Division. c2002.
- Chang S, Sun W, Cho SG, Kim D. Vibration Control of Nuclear Power Plant Piping System Using Stockbridge Damper under Earthquakes. Science and Technology of Nuclear Installations. 2016;201: Article ID 5014093.
- Techniques of the Snubber Testing in a Nuclear Power Plant. Korea Atomic Energy Research Institute. KAERI/AR-395/94. 1994,
- Cho YB, Moon GY, Yoo HJ. Status of Inspection and Management for Nuclear Power Plants Snubbers. J KPVP. 2014;10(1):20-24.
- Cho SG, Furuya O, Kurabayashi H. Study on s evere accident management measures for the pinping system in nuclear power plant using vibration control techniques. 24th Conference on Structural Mechanics in Reactor Technology; 2017 August 20-25; BEXCO, Busan, Korea; c2017.
- Cho SG, Furuya O, Kurabayashi H. Enhancement of Seismic Resilience of Piping Systems in Nuclear Power Plants Using Steel Coil Damper. J Nuclear Engineering and Design. 2019;350:147-157. https://doi.org/10.1016/j.nucengdes.2019.05.006
- Cho SG, Furuya O, Kurabayashi H. Vibration Control of Piping System in Nuclear Power Plant Using Elasto-plastic Steel Coil Spring Damper under Earthquake. Transactions of the Korean Nuclear Society Spring Meeting; 2019 May 23-24; Jeju, Korea; c2019.
- Design Guidelines of a Spring-Damper System for Emergency Diesel Generator Sets. KAERI/TR-3363 /2007. Korea Atomic Energy Research Institute. c2007.
- Nakamura I, Otani A, Shiratori M. A Study on Fracture Mechanics of Eroded Pipes under Seismic Loading. National Research Institute for Earth Science and Disaster Prevention, Japan. c2007. p. 306.
- ANSYS Inc. ANSYS Workbench, Version 2019 R3; c2009.
- IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations. IEEE Std 344: IEEE; c2004.