DOI QR코드

DOI QR Code

A case of digital maxillary complete denture and mandibular implant overdenture fabricated by CAD-CAM technique

완전 무치악 환자에서 CAD-CAM 기법을 이용한 상악 총의치 및 하악 임플란트 피개의치 수복: 증례 보고

  • Kim, Kun Min (Department of Prosthodontics, Yonsei University College of Dentistry) ;
  • Oh, Kyung Chul (Department of Prosthodontics, Yonsei University College of Dentistry) ;
  • Kim, Sang Hyun (Department of Prosthodontics, Yonsei University College of Dentistry) ;
  • Han, Chol Gwan (Department of Prosthodontics, Yonsei University College of Dentistry) ;
  • Kim, Jee Hwan (Department of Prosthodontics, Yonsei University College of Dentistry)
  • 김건민 (연세대학교 치과대학 치과보철학교실) ;
  • 오경철 (연세대학교 치과대학 치과보철학교실) ;
  • 김상현 (연세대학교 치과대학 치과보철학교실) ;
  • 한철관 (연세대학교 치과대학 치과보철학교실) ;
  • 김지환 (연세대학교 치과대학 치과보철학교실)
  • Received : 2021.06.04
  • Accepted : 2021.09.13
  • Published : 2021.10.31

Abstract

The CAD-CAM technique is a rapidly developing field in the dental field and is applied to various fields of prosthetic treatment. Among them, the manufacturing of dentures using the milling technique classified as subtractive manufacturing is one of the commercialized digital full denture manufacturing methods. At the same time, it is possible to more efficiently manufacture a metal framework for implant overdenture by selective laser sintering or melting technique classified as an additive manufacturing method. The purpose of this article is to describe the fabrication of CAD-CAM maxillary complete denture and mandibular implant overdenture as well as its features.

컴퓨터 지원 설계 및 제조 기법(CAD-CAM)은 치과 영역에서 급속도로 발전해온 분야로, 다양한 보철 치료 영역에 적용되고 있다. 이 중 절삭형 방식(Subtractive Manufacturing)으로 분류되는 절삭가공 기법을 이용한 의치 제작은 상용화된 디지털 총의치 제작 방식 중 하나이며, 동시에 첨가형 방식(Additive Manufacturing)으로 분류되는 레이저 소결 혹은 용융 기법을 활용하여 피개의치를 위한 금속구조물을 보다 효율적으로 제작할 수 있게 되었다. 본 증례에서는, CAD-CAM을 통해 절삭형 방식으로 제작한 상악 총의치와 3D 금속 프린팅을 이용한 금속구조물과 절삭형 방식으로 제작된 인공치를 접목한 하악 임플란트 피개의치를 제작하였다. 이를 통해 기능적, 심미적으로 적절한 임상적 결과를 얻었으므로 이를 보고하는 바이다.

Keywords

References

  1. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, TawseSmith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002;19:3-4. https://doi.org/10.1111/j.1741-2358.2002.00003.x
  2. Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients--the York Consensus Statement. Br Dent J 2009;207:185-6. https://doi.org/10.1038/sj.bdj.2009.728
  3. Goodacre C, Goodacre B. Fixed vs removable complete arch implant prostheses: A literature review of prosthodontic outcomes. Eur J Oral Implantol 2017;10:13-34.
  4. Koutsoukis T, Zinelis S, Eliades G, Al-Wazzan K, Rifaiy MA, Al Jabbari YS. Selective laser melting technique of Co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques. J Prosthodont 2015;24:303-12. https://doi.org/10.1111/jopr.12268
  5. Arslan M, Murat S, Alp G, Zaimoglu A. Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures. Int J Comput Dent 2018;21:31-40.
  6. Choi JJE, Uy CE, Plaksina P, Ramani RS, Ganjigatti R, Waddell JN. Bond strength of denture teeth to heatcured, CAD/CAM and 3D printed denture acrylics. J Prosthodont 2020;29:415-21. https://doi.org/10.1111/jopr.13125
  7. Yamamoto S, Kanazawa M, Hirayama D, Nakamura T, Arakida T, Minakuchi S. In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures. Comput Biol Med 2016;68:84-9. https://doi.org/10.1016/j.compbiomed.2015.11.004
  8. Sayed ME, Swaid SM, Porwal A. Effect of cast modification on linear dimensional change of acrylic tooth position following maxillary complete denture processing. J Prosthodont 2017;26:659-63. https://doi.org/10.1111/jopr.12445