DOI QR코드

DOI QR Code

Flabby tissue 환자에서 기능과 안정을 고려한 편악 총의치 수복 증례

Maxillary complete denture rehabilitation in flabby tissue patient considering of function and stability: A clinical report

  • 최영균 (경희대학교 일반대학원 치과보철학교실) ;
  • 이영후 (경희대학교치과병원 보철과) ;
  • 홍성진 (경희대학교치과병원 보철과) ;
  • 백장현 (경희대학교 치과대학.치의학전문대학원 치과보철학교실) ;
  • 노관태 (경희대학교 치과대학.치의학전문대학원 치과보철학교실) ;
  • 배아란 (경희대학교 치과대학.치의학전문대학원 치과보철학교실) ;
  • 김형섭 (경희대학교 치과대학.치의학전문대학원 치과보철학교실) ;
  • 권긍록 (경희대학교 치과대학.치의학전문대학원 치과보철학교실)
  • Choi, Youngkyun (Department of Prosthodontics, Graduate School, Kyung Hee University) ;
  • Lee, Younghoo (Department of Prosthodontics, Kyung Hee University Dental Hospital) ;
  • Hong, Seoung-Jin (Department of Prosthodontics, Kyung Hee University Dental Hospital) ;
  • Paek, Janghyun (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Noh, Kwantae (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Pae, Ahran (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Kim, Hyeong-Seob (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Kwon, Kung-Rock (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
  • 투고 : 2021.05.18
  • 심사 : 2021.07.07
  • 발행 : 2021.10.31

초록

Flabby tissue를 가진 환자의 상악 편악 총의치 수복 시 의치의 유지, 지지, 안정을 얻는 것은 어렵다. 본 증례 환자분은 57세 남환으로 기존 의치의 불편감과 치료를 원하시어 내원 하셨다. Flabby tissue 환자의 총의치 수복 시 flabby tissue 부위가 움직임이 없는 상태로 인상채득을 하는 것이 총의치 보철의 안정에 중요한 요소이다. 디지털 기술의 발전으로 구강 내 조직의 스캔이 가능해져 flabby tissue 부위의 완전 무압인상이 가능해졌다. 이를 이용하여 무압인상 채득하고 최종 의치를 진행하였다. 교합 시 의치의 지지, 유지, 안정의 개선된 결과를 얻었기에 이를 보고하는 바이다.

It is very difficult to achieve denture support, stability and retention in single-maxillary complete denture patients with flabby tissue. A 57-year-old male patient was uncomfortable with the existing denture and wanted treatment. The reduction of flabby tissue was confirmed using the treatment denture. Non-pressure impression was obtained using an intraoral scanner during the definitive denture process. This is reported because the resulting denture improved when observing the retention, support and stability of the denture during occlusion.

키워드

참고문헌

  1. Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete denture retention, stability, and support. Part I: retention. J Prosthet Dent 1983;49:5-15. https://doi.org/10.1016/0022-3913(83)90228-7
  2. Lynch CD, Allen PF. Management of the flabby ridge: using contemporary materials to solve an old problem. Br Dent J 2006;200:258-61. https://doi.org/10.1038/sj.bdj.4813306
  3. Allen F. Management of the flabby ridge in complete denture construction. Dent Update 2005;32:524-6, 528. https://doi.org/10.12968/denu.2005.32.9.524
  4. Koper A. The maxillary complete denture opposing natural teeth: problems and some solutions. J Prosthet Dent 1987;57:704-7. https://doi.org/10.1016/0022-3913(87)90367-2
  5. Hong SJ, Lee H, Paek J, Pae A, Kim HS, Kwon KR, Noh K. Combining conventional impressions and intraoral scans: a technique for the treatment of complete denture patients with flabby tissue. J Prosthodont 2019;28:592-5. https://doi.org/10.1111/jopr.13060
  6. Fradeani M. Esthetic analysis: A systematic approach to prosthetic treatment. Quintessence 2004. p156-61.
  7. Shin JO, Ko KH, Huh YH, Cho LR, Park CJ. Displacement of simulated flabby tissue by different tray designs and impression materials. J Prosthodont 2019;28:444-51. https://doi.org/10.1111/jopr.13036
  8. Hong SJ, Noh K. Setting the sagittal condylar inclination on a virtual articulator by using a facial and intraoral scan of the protrusive interocclusal position: A dental technique. J Prosthet Dent 2021;125:392-5. https://doi.org/10.1016/j.prosdent.2020.01.031
  9. Hobo S, Mochizuki S. Study of mandibular movement by means of an electronic measuring system. (Part 1). J Jpn Prosthodont 1982;26:619-34. https://doi.org/10.2186/jjps.26.619
  10. Lee JJ, Kim DH, Noh K. A technique for transferring the contours of a functional impression to the polished surfaces of digitally fabricated removable complete dentures. J Prosthet Dent 2020;124:153-6. https://doi.org/10.1016/j.prosdent.2019.05.038
  11. Cha HS, Park JM, Kim TH, Lee JH. Wear resistance of 3D-printed denture tooth resin opposing zirconia and metal antagonists. J Prosthet Dent 2020;124:387-94. https://doi.org/10.1016/j.prosdent.2019.09.004
  12. Ahn JJ, Huh JB, Choi JW. In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods. J Korean Acad Prosthodont 2019;57:110-7. https://doi.org/10.4047/jkap.2019.57.2.110