DOI QR코드

DOI QR Code

Three-dimensional intraoperative computed tomography imaging for zygomatic fracture repair

  • Peleg, Oren (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University) ;
  • Ianculovici, Clariel (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University) ;
  • Shuster, Amir (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University) ;
  • Mijiritsky, Eitan (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University) ;
  • Oz, Itay (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University) ;
  • Kleinman, Shlomi (Department of Otolaryngology Head and Neck Surgery and Maxillofacial Surgery, Tel Aviv Sourasky Medical Center, Sackler School of Medicine, Tel Aviv University)
  • Received : 2021.03.06
  • Accepted : 2021.06.28
  • Published : 2021.10.31

Abstract

Objectives: Zygomatic complex (ZMC) fractures comprise up to 40% of all facial fractures. Misaligned bone fragments and misplaced fixation hardware traditionally detected postoperatively on plain radiographs of the skull might require re-operation. The intraoperative O-Arm (Medtronic, USA) is a three-dimensional (3D) computed tomographic imaging system. Materials and Methods: This retrospective single-center study evaluated the utility of O-Arm scanning during corrective surgeries for ZMC and zygomatic arch (ZA) fractures from 2018 to 2020. Three females and 16 males (mean age, 31.52 years; range, 22-48 years) were included. Fracture instability (n=6) and facial deformity (n=15) were the most frequent indications for intraoperative 3D O-Arm scan. Results: The images demonstrated that all fracture lines were properly reduced and fixed. Another scan performed at the end of the fixation or reduction stage, however, revealed suboptimal results in five of the 19 cases, and further reduction and fixation of the fracture lines were required. Conclusion: Implementation of an intraoperative O-Arm system in ZMC and ZA fracture surgeries assists in obtaining predictable and accurate results and obviates the need for revision surgeries. The device should be considered for precise operations such as ZMC fracture repairs.

Keywords

References

  1. Kelley P, Hopper R, Gruss J. Evaluation and treatment of zygomatic fractures. Plast Reconstr Surg 2007;120(7 Suppl 2):5S-15S. https://doi.org/10.1097/01.prs.0000260720.73370.d7
  2. Bogusiak K, Arkuszewski P. Characteristics and epidemiology of zygomaticomaxillary complex fractures. J Craniofac Surg 2010;21:1018-23. https://doi.org/10.1097/scs.0b013e3181e62e47
  3. Marinho RO, Freire-Maia B. Management of fractures of the zygomaticomaxillary complex. Oral Maxillofac Surg Clin North Am 2013;25:617-36. https://doi.org/10.1016/j.coms.2013.07.011
  4. Gomes PP, Passeri LA, Barbosa JR. A 5-year retrospective study of zygomatico-orbital complex and zygomatic arch fractures in Sao Paulo State, Brazil. J Oral Maxillofac Surg 2006;64:63-7. https://doi.org/10.1016/j.joms.2005.09.012
  5. Adam AA, Zhi L, Bing LZ, Zhong Xing WU. Evaluation of treatment of zygomatic bone and zygomatic arch fractures: a retrospective study of 10 years. J Maxillofac Oral Surg 2012;11:171-6. https://doi.org/10.1007/s12663-011-0294-x
  6. Gulicher D, Krimmel M, Reinert S. The role of intraoperative ultrasonography in zygomatic complex fracture repair. Int J Oral Maxillofac Surg 2006;35:224-30. https://doi.org/10.1016/j.ijom.2005.10.005
  7. Kim JS, Park YJ, Lee YJ, Kim NG, Lee KS. Reduction of zygomatic arch isolated fracture using ultra sound and needle marking. Arch Craniofac Surg 2016;17:198-201. https://doi.org/10.7181/acfs.2016.17.4.198
  8. Ellis E 3rd, Perez D. An algorithm for the treatment of isolated zygomatico-orbital fractures. J Oral Maxillofac Surg 2014;72:1975-83. https://doi.org/10.1016/j.joms.2014.04.015
  9. Ostrofsky MK, Lownie JF. Zygomatico-coronoid ankylosis. J Oral Surg 1977;35:752-4.
  10. Khaqani MS, Tavosi F, Gholami M, Eftekharian HR, Khojastepour L. Analysis of facial symmetry after zygomatic bone fracture management. J Oral Maxillofac Surg 2018;76:595-604. https://doi.org/10.1016/j.joms.2017.10.005
  11. Manson PN, Clifford CM, Su CT, Iliff NT, Morgan R. Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligament sling and its relation to intramuscular cone orbital fat. Plast Reconstr Surg 1986;77:193-202. https://doi.org/10.1097/00006534-198602000-00004
  12. Barry C, Coyle M, Idrees Z, Dwyer MH, Kearns G. Ocular findings in patients with orbitozygomatic complex fractures: a retrospective study. J Oral Maxillofac Surg 2008;66:888-92. https://doi.org/10.1016/j.joms.2008.01.005
  13. Maheedhar AV, Ravindran C, Azariah ED. Use of C-arm to assess reduction of zygomatic complex fractures: a comparative study. Craniomaxillofac Trauma Reconstr 2017;10:35-43. https://doi.org/10.1055/s-0036-1592085
  14. van Hout WM, Van Cann EM, Muradin MS, Frank MH, Koole R. Intraoperative imaging for the repair of zygomaticomaxillary complex fractures: a comprehensive review of the literature. J Craniomaxillofac Surg 2014;42:1918-23. https://doi.org/10.1016/j.jcms.2014.07.012
  15. Jank S, Deibl M, Strobl H, Oberrauch A, Nicasi A, Missmann M, et al. Interrater reliability of sonographic examinations of orbital fractures. Eur J Radiol 2005;54:344-51. https://doi.org/10.1016/j.ejrad.2004.07.009
  16. Jenkins CN, Thuau H. Ultrasound imaging in assessment of fractures of the orbital floor. Clin Radiol 1997;52:708-11. https://doi.org/10.1016/s0009-9260(97)80037-2
  17. Hoelzle F, Klein M, Schwerdtner O, Lueth T, Albrecht J, Hosten N, et al. Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures. Int J Oral Maxillofac Surg 2001;30:26-31. https://doi.org/10.1054/ijom.2000.0014
  18. Hoffmann J, Krimmel M, Dammann F, Reinert S. [Feasibility of intraoperative diagnosis with a mobile computed tomography scanner]. Mund Kiefer Gesichtschir 2002;6:346-50. German. https://doi.org/10.1007/s10006-002-0406-3
  19. Stanley RB Jr. Use of intraoperative computed tomography during repair of orbitozygomatic fractures. Arch Facial Plast Surg 1999;1:19-24. https://doi.org/10.1001/archfaci.1.1.19
  20. Uneri A, Zhang X, Yi T, Stayman JW, Helm PA, Theodore N, et al. Image quality and dose characteristics for an O-arm intraoperative imaging system with model-based image reconstruction. Med Phys 2018;45:4857-68. https://doi.org/10.1002/mp.13167
  21. Sarwahi V, Payares M, Wendolowski S, Maguire K, Thornhill B, Lo Y, et al. Low-dose radiation 3D intraoperative imaging: how low can we go? An O-arm, CT scan, cadaveric study. Spine (Phila Pa 1976) 2017;42:E1311-7. https://doi.org/10.1097/BRS.0000000000002154
  22. Verhofste BP, Glotzbecker MP, Hresko MT, MacDougall RD, Birch CM, O'Neill NP, et al. Intraoperative use of O-arm in pediatric cervical spine surgery. J Pediatr Orthop 2020;40:e266-71. https://doi.org/10.1097/BPO.0000000000001416
  23. Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008;248:254-63. https://doi.org/10.1148/radiol.2481071451
  24. Wilde F, Lorenz K, Ebner AK, Krauss O, Mascha F, Schramm A. Intraoperative imaging with a 3D C-arm system after zygomaticoorbital complex fracture reduction. J Oral Maxillofac Surg 2013;71:894-910. https://doi.org/10.1016/j.joms.2012.10.031
  25. Kurita M, Okazaki M, Ozaki M, Tanaka Y, Tsuji N, Takushima A, et al. Patient satisfaction after open reduction and internal fixation of zygomatic bone fractures. J Craniofac Surg 2010;21:45-9. https://doi.org/10.1097/SCS.0b013e3181c36304