A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Jia, Wenbao (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Jin, Limin (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Shan, Qing (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Cheng, Can (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Zhu, Hongkui (College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics) ;
  • Hei, Daqian (School of Nuclear Science and Technology, Lanzhou University)
  • Received : 2020.06.25
  • Accepted : 2021.03.02
  • Published : 2021.09.25

Abstract

Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

Keywords

Acknowledgement

This work was funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions China.

References

  1. Burkhard Beckhoff, Birgit KanngieBer, Norbert Langhoff, Reiner Wedell, H. Wolff, Handbook of Practical X-Ray Fluorescence Analysis, first ed., Springer-Verlag, Berlin, 2006.
  2. S. Maeo, M. Kramer, K. Taniguchi, Development of a microfocus x-ray tube with multiple excitation sources, Rev. Sci. Instrum. 80 (2009), 033108. https://doi.org/10.1063/1.3095551
  3. S. Maeo, M. Kramer, T. Utaka, K. Taniguchi, Development of a micro-focus x-ray fluorescence spectrometer using multiple target anode monochromatic x-ray sources, X Ray Spectrom. 38 (2009) 333-337. https://doi.org/10.1002/xrs.1168
  4. T.-h. Nguyen, C.J. Lee, R.-j. Park, G.-H. Jin, S.Y. Kim, I. Jeon, Note: a simple-structured anode exchangeable X-ray tube, Rev. Sci. Instrum. 84 (2013), 056108. https://doi.org/10.1063/1.4807755
  5. L. Jin, W. Jia, D. Hei, X. Zhang, L. Zhao, Development of an X-ray tube with two selective targets modulated by a magnetic field, Rev. Sci. Instrum. 90 (2019), 083105. https://doi.org/10.1063/1.5094914
  6. B.J. Walker, J. Radtke, G.-H. Chen, K.W. Eliceiri, T.R. Mackie, A beam optics study of a modular multi-source X-ray tube for novel computed tomography applications, Nucl. Instrum. Methods Phys. Res., Sect. A 868 (2017) 1-9. https://doi.org/10.1016/j.nima.2017.06.035
  7. M. Iqbal, M.A.K. Lodhi, Z. Majeed, D. Batani, Electrostatic focusing of directly heated linear filament gun using EGUN, Nucl. Instrum. Methods Phys. Res., Sect. A 641 (2011) 1-4. https://doi.org/10.1016/j.nima.2011.02.081
  8. M.M. Nasseri, Determination of tungsten target parameters for transmission X-ray tube: a simulation study using Geant4, Nucl. Engi. Tech. 18 (2016) 795-798. https://doi.org/10.1016/j.net.2016.01.006
  9. M.M. Nasseri, Determination of molybdenum target parameters for transmission X-ray tube: a Geant4 simulation study, Pramana 92 (2019) 54. https://doi.org/10.1007/s12043-019-1718-2
  10. A. Ihsan, S.H. Heo, S.O. Cho, Optimization of X-ray target parameters for a high-brightness microfocus X-ray tube, Nucl. Instrum. Methods Phys. Res., Sect. B 264 (2007) 371-377. https://doi.org/10.1016/j.nimb.2007.09.023
  11. A. Miceli, R. Thierry, M. Bettuzzi, A. Flisch, J. Hofmann, U. Sennhauser, F. Casali, Comparison of simulated and measured spectra of an industrial 450kV X-ray tube, Nucl. Instrum. Methods Phys. Res., Sect. A 580 (2007) 123-126. https://doi.org/10.1016/j.nima.2007.05.025
  12. A. Ihsan, S.H. Heo, S.O. Cho, A microfocus X-ray tube based on a microstructured X-ray target, Nucl. Instrum. Methods Phys. Res., Sect. B 267 (2009) 3566-3573. https://doi.org/10.1016/j.nimb.2009.08.012
  13. P. Schardt, J. Deuringer, J. Freudenberger, E. Hell, W. Knupfer, D. Mattern, M. Schild, New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology, Med. Phys. 31 (2004) 2699-2706. https://doi.org/10.1118/1.1783552
  14. R. Kumar, S.R. Ratnala, G.B. Veeresh Kumar, P.S.S. Gouda, Thermal Analysis on X-Ray Tube for Exhaust Process, IOP Publishing, Bengaluru, India, 2018, 012162. IOP Conference Series: Materials Science and Engineering.
  15. L.N. Koppel, J.R. Marshall, A miniature metaleceramic x-ray source for spacecraft instrumentation, Rev. Sci. Instrum. 69 (1998) 1893-1897. https://doi.org/10.1063/1.1148860
  16. A. Goldberg, Joining of Beryllium, Lawrence Livermore National Lab. (LLNL), United States, 2006.
  17. A. Goldberg, Atomic, Crystal, Elastic, Thermal, Nuclear, and Other Properties of Beryllium, Lawrence Livermore National Lab. (LLNL), United States, 2006.
  18. C. Tan, C. Tang, W. Huang, Q. Jin, Y. Du, Q. Luo, P. Wu, D. Liu, L. Zhang, C. Xu, Beam simulation and experiment of multi-focal spot electron gun for distributed X-ray sources, Nucl. Instrum. Methods Phys. Res., Sect. A 920 (2019) 43-49. https://doi.org/10.1016/j.nima.2018.11.039
  19. K. Watanabe, M. Mizuno, Y. Ohara, M. Tanaka, K. Kobayashi, E. Takahashi, T. Uede, Dc voltage holding experiments of vacuum gap for high-energy ion sources, J. Appl. Phys. 72 (1992) 3949-3956. https://doi.org/10.1063/1.352247
  20. H.S. Raza, H.J. Kim, J.M. Ha, S.O. Cho, Behavior of characteristic X-rays from a partial-transmission-type X-ray target, Appl. Radiat. Isot. 80 (2013) 67-72. https://doi.org/10.1016/j.apradiso.2013.06.009
  21. C. Zhaoxi, H. Liqun, C. Yong, L. Mingzhun, C. Yebin, S. Yuntao, The design and test of a Be window for the ITER radial X-ray camera, Plasma Sci. Technol. 15 (2013) 1160-1164. https://doi.org/10.1088/1009-0630/15/11/15