옥내소화전설비에서 도너츠형 적재방식의 소방호스 전개형태에 따른 방수준비시간 비교

Comparison of Waterproofing Preparation Time with the Unfolded of Donut-type Staking Method Fire Hose in Indoor Hydrant System

  • 투고 : 2021.08.30
  • 심사 : 2021.09.15
  • 발행 : 2021.09.30

초록

In this study, the purpose of this study was to examine the effect of twisting in the preparation of waterproofing in the process of unfolded donut-type staking method fire hoses in indoor hydrant system. The central pull-out method caused more twisting than the rolling method, and there was no significant difference in the number of twists according to the pull-out method in the case of male and female students. It was found that the time it took to untwist and prepare waterproofing was much shorter for male students. The angle valve and hose are connected, and the time to untwist and prepare for waterproofing after withdrawing the fire hose with the hose and nozzle connected was shorter than the unconnected state. In the rolling method, when a hose connected with two 15 m fire hoses was used and the angle valve-hose was connected, but the hose-nozzle was not connected, the least kinking occurred. The time to untwist and prepare for waterproofing was also the shortest. As a result, in the withdrawal method of the donut-type loaded fire hose in the indoor hydrant system, it is a rolling method rather than a central withdrawal method. With the angle valve and hose connected, unfold the fire hose with the hose and nozzle connected, if a large number of people unwind the twisted hose, the time to prepare for waterproofing can be shortened.

키워드

참고문헌

  1. J. B. Kim, C. S. Baek, H. J. Kim(2001), "A study on adhesion test methods for fire hose." J. of Korean Institute of Fire Sci. & Eng., 15(1):66-74.
  2. H. S. Kong, J. H. Lee, K. C. Kim(2008), "A study on turning connection nine for function elevation of fire hose." Journal of the Korean Institute of Plant Engineering, 13(2):99-105.
  3. National Fire Agency(2019), Fire safety standards for indoor hydrant system (NFSC 102), The amount of water stored in the water source of the indoor hydrant system. p. 33.
  4. H. E. Lee(2020). A study on pressure losses in fire hose in various deployment situations. University of Seoul, pp. 77-80.
  5. Y. K. Whang, S. C. Lee(2019), "Study on the pressure loss of hoses in a fire hose reel hydrant." Fire Sci. Eng., 33(2):63-67.
  6. S. H. Hong, H. S. Kong(2021a), "Measurement of the time taken for initial water discharge according to the number of kinks in the fire hose of the indoor hydrant system." Self-research Report.
  7. S. H. Hong, H. S. Kong(2021b), "Analysis of the number of kinks with the fire hose staking method of indoor hydrant system." Self-research Report.
  8. Ministry of Government Legislation(2019, January 10), "Type approval of fire hose and technical standard for product inspection." Article 2 No. 7-14.
  9. Ministry of Government Legislation(2021), "Enforcement decree of the act on fire prevention, installation and maintenance of firefighting facilities, and safety management [Annex 5]." Amended on 1.5.
  10. Ministry of Government Legislation(2021, April 1), "Fire safety standards for indoor hydrant system." Article 7(2), Partial Revision.