DOI QR코드

DOI QR Code

Development of Complex Module Device for Odor Reduction in Sewage

  • 투고 : 2021.08.14
  • 심사 : 2021.09.29
  • 발행 : 2021.09.30

초록

Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

키워드

참고문헌

  1. Abalos, M., Bayona J. M., & Ventura, F. (1999). Development of a Solid-Phase Microextraction GC-NPD Procedure for the Determination of Free Volatile Amines in Wastewater and Sewage-Polluted Waters. Analytical Chemistry, 71, 3531-3537. doi: 10.1021/ac990197h
  2. Alinezhad, E., Mohsen, H., Rahmani, F., Keshizadeh, H., Abdi, M., & Naddafi, K. (2019). Technical and economic investigation of chemical scrubber and bio-filtration in removal of H2S and NH3 from wastewater treatment plant. Journal of Environmental Management, 241, 32-43. doi: 10.1016/j.jenvman.2019.04.003
  3. Barbusinski, K., Kalemba, K., Kasperczyk, D., Urbaniec, K., Kozik, V. (2017). Biological methods for odor treatment - A review. Journal of Cleaner Production, 152, 223-241. doi: 10.1016/j.jclepro.2017.03.093
  4. Easter, C., Quigley, C., Burrows, P., Witherspoon, J., &Apgar, D. (2005). Odor and air emissions control using biotechnology for both collection and wastewater treatment systems. Chemical Engineering Journal, 113, 93-104. doi: 10.1016/j.cej.2005.04.007
  5. Gandu, B., Palanivel, S., Juntupally, S., Arelli, V., Begum, S., & Anupoju., G. R. (2021). Removal of NH3 and H2S from odor causing tannery emissions using biological filters: Impact of operational strategy on the performance of a pilot-scale biofilter. Journal of Environmental Science and Health, Part A, 56, 625-634. https://doi.org/10.1080/10934529.2021.1903283
  6. Gostelow, P., Parsons, S.A., & Stuetz, R.M. (2001). Odour measurements for sewage treatment works. Water Research, 35(3), 579-597. doi: 10.1016/S0043-1354(00)00313-4
  7. Han, Z., Qi, F., Wang, H., Li, R., & Sun, D. (2019). Odor assessment of NH3 and volatile sulfide compounds in a full-scale municipal sludge aerobic composting plant. Bioresource Technology, 282, 477-455.
  8. Jang, H., Kim, S., Lee, J. K., Oh, N., & Song, J. (2017). Estimating the odor emission factors of the grit removal chambers of publicly-owned wastewater treatment plants. Journal of Odor and Indoor Environment, 16(4), 393-400. doi: 10.15250/joie.2017.16.4.393
  9. Jiang, X., & Tay, J. H. (2010). Operational characteristics of efficient co-removal of H2S and NH3 in a horizontal biotrickling filter using exhausted carbon. Journal of Hazardous Materials, 176, 638-643. doi: 10.1016/j.jhazmat.2009.11.079
  10. Jung, M. J., Kim, Y. D., Kwon, L. S., Lee, W. S., & Kwon, W. T. (2018). A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry. International Journal of Industrial Distribution & Business, 9(12), 23-29. https://doi.org/10.13106/ijidb.2018.vol9.no12.23.
  11. Kang, S. W., Lee, J. S., Lee, K. S., Lim, H. A., Kim, J. S., Lee, J. D., Park, W. S., & Park, Y. K. (2020). Decomposition of odor using atmospheric-pressure plasma. Journal of the Korea Academia-Industrial Cooperation Society, 21(7), 708-718. doi: 10.5762/KAIS.2020.21.7.708
  12. Kennes, C., & Thalasso, F. (1998). Review: Waste gas biotreatment technology. Journal of Chemical Technology & Biotechnology, 72, 303-319. doi: 10.1002/(SICI)1097-4660(199808)72:4<303::AID-JCTB903>3.0.CO;2-Y
  13. Kim, H., Kim, Y. J., & Chung J. S. (2002). Long-Term Operation of a Bio-filter for Simultaneous Removal of H2S and NH3. Journal of the Air & Waste Management Association, 52, 1389-1398. doi: 10.1080/10473289.2002.10470871
  14. Kim, J., Sekyama, K., Lee, D., & Kim, H. (2006). Odors from Wastewater Treatment Plants. Korean Journal of Odor Research and Engineering, 5(3), 180-192.
  15. Kim, K.-O., Kim, Y.-J., & Won, Y.-S. (2008). Removal of VOCs and H2S from Waste Gas with Biotrickling Filter. Journal of Industrial and Engineering Chemistry, 19(5), 519-525.
  16. Kim, S.-H., Lee, S.-H., Yun, Y.-J., Choi, S.-Y., Jung, M.-J., & Kwon, W.-T. (2021). A Study on the Sewage Sludge Odor Control System. Journal of Wellbeing Management and Applied Psychology, 4(2), 19-25. https://doi.org/10.13106/JWMAP.2021.VOL4.NO2.19
  17. Ko, B. C., Lee, J. K., Lee, Y. S., Lee, M. G., & Kam, S. K. (2012). A Study on Odor Emission Characteristics of Domestic Sewage Treatment Facilities Using Composite Odor Concentration and Hydrogen Sulfide Concentration. Journal of the Environmental Sciences, 21(11), 1379-1388. doi: 10.5322/JES.2012.21.11.1379
  18. Lee, B. K., Lee, S. H., Tak, S. J., & Lee, B. K. (2017). The Study on the Removal of Odor Emitting Environmental Fundamental Facility. Journal of Climate Change Research, 8(1), 5-56.
  19. Lee, M. S., Kang, D. H., Keum, J. L., Kwon, B. Y., Jo, H. W., Lee, C. H., Kim, E. D., Lim, H. J., & Song, H. B. (2018). Emission Characteristics of Odor Compounds from a Sewage Treatment Plant Near an Industrial Complex Area in Daegu City. Journal of Environmental Health Sciences, 44(2), 178-187. doi: 10.5668/JEHS.2018.44.2.178
  20. Lee, M., Li, P., Koziel, J. A., Ahn, H., Wo, J., Chen, B., Meiirkhanuly, Z., Banik, C., & Jenks, W. S. (2020). Pilot-Scale Testing of UV-A Light Treatment for Mitigation of NH3, H2S, GHGs, VOCs, Odor, and O3 Inside the Poultry Barn. Frontiers in Chemistry, 8, 613. https://doi.org/10.3389/fchem.2020.00613
  21. Lee, T., Lee, J., & Lee, J. (2009). Determination of Major Reduced Sulfur Gases Emitted from Wastes Stored in Environmental Facility Using GC/FPD. Journal of the Korean Geo-Environmental Society, 10(2), 37-43.
  22. Liang, J. Cheng, G., & Feng, H. (2016). Engineering practices of deodorization for odor in urban sewage treatment plants in China. Advances in Economics, Business and Management Research, 30, 86-91.
  23. Ministry of Environment(MOE). (2021). Environment Statistics Portal. Retrieved July 23, 2021 (actual access data), from http://stat.me.go.kr/nesis/mesp2/webStatistics/stat_main.jsp?tblID=DT_106N_99_2400002&inq_gubun=1&lang=kor&list_id=106H_01_002014&l_interval=2
  24. Morral, E., Gabriel, D., Dorado, A. D., & Gamisans, X. (2021). A review of biotechnologies for the abatement of ammonia emissions. Chemosphere, 273, 128006.
  25. National Institute of Environmental Research(NIER). (2018a). Standard Method of Odor Compounds ES 09302.1a ammonia - boric acid solution absorption - ultraviolet/visible spectrometry.
  26. National Institute of Environmental Research(NIER). (2018b). Standard Method of Odor Compounds ES 09303.1a sulfur compounds - cold trap - capillary GC method.
  27. National Institute of Environmental Research(NIER). (2019). Standard Method of Odor Compounds ES 09301.b air dilution olfactory method.
  28. National Institute of Environmental Research(NIER). (2021). Standard Methods for the Measurements of Air Pollution ES 01607.1a Method for the Determination of Ozone in Ambient Air - Ultraviolet Photometric Method.
  29. Seo, B. R., Jeon, H. S., Park, Y. S., Yun, B. R., Jang, T., & Kim, T. (2013). The Emission Characteristics and Management of Odor Compounds from Public Sewage Treatment Facility. Journal of Korean Society of Odor Research and Engineering, 12(3), 97-109. https://doi.org/10.11161/jkosore.2013.12.3.97
  30. Shammay, A., Sivret, E. C., Le-Minh, N., Fernandez, R. L., Evanson, I., & Stuetz, R. M. (2016). Review of odour abatement in sewer networks. Journal of Environmental Chemical Engineering, 4, 3866-3881. doi: 10.1016/j.jece.2016.08.016
  31. Sun, G., Guo, H., & Peterson, J. (2010). Seasonal Odor, Ammonia, Hydrogen Sulfide, and Carbon Dioxide Concentrations and Emissions from Swine Grower-Finisher Rooms.Journal of the Air & Waste Management Association, 60, 471-480. doi: 10.3155/1047-3289.60.4.471
  32. Sun, G., Guo, H., Peterson, J., Predicala, B., & Lague, C. (2008). Diurnal odor, ammonia, hydrogen sulfide, and carbon dioxide emission profiles of confined swine grower/finisher rooms. Journal of the Air & Waste Management Association, 58, 1434-1448. doi: 10.3155/1047-3289.58.11.1434
  33. Won, Y. S. (2007). Biotreatment Technologies for Air Pollution Control. CLEAN TECHNOLOGY, 13(1), 1-15. doi: 10.1007/s10098-010-0342-0
  34. Yeo, U. H., Lee, I. B., Ha, T. H., Decano, C., Kim, R. W., Lee, S. Y., Kim, J. G., Choi, Y. B., & Park, Y. M. (2019).Evaluation of Odor Dispersion from Livestock Building through Field Experiment. Journal of the Korean Society of Agricultural Engineers, 61(6), 21-30.
  35. Zarra, T., Giuliani, S., Naddeo, V., & Belgiorno, V. (2012). Control of odour emission in wastewater treatment plants by direct and undirected measurement of odour emission capacity. Water Science & Technology, 66(8), 1627-1633. doi: 10.2166/wst.2012.362