DOI QR코드

DOI QR Code

지대주 나사 조임 토크가 맞춤형 지대주 임플란트 시스템의 연결부 안정성에 미치는 영향: 3차원 유한 요소 해석

Effect of tightening torque on the connection stability of a custom-abutment implant system: 3D finite element analysis

  • 홍민호 (부산가톨릭대학교 보건과학대학 치기공학과)
  • Hong, Min-Ho (Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan)
  • 투고 : 2021.08.18
  • 심사 : 2021.09.16
  • 발행 : 2021.09.30

초록

Purpose: This study aims to examine the stress distribution effect of tightening torques of different abutment screws in a custom-abutment implant system on the abutment-fixture connection interface stability using finite element analysis. Methods: The custom-abutment implant system structures used in this study were designed using CATIA program. It was presumed that the abutment screws with a tightening torque of 10, 20, and 30 N·cm fixed the abutment and fixture. Furthermore, two external loadings, vertical loading and oblique loading, were applied. Results: When the screw tightening torque was 10 N·cm, the maximum stress value of the abutment screw was 287.2 MPa that is equivalent to 33% of Ti-6Al-4V yield strength. When the tightening torque was 20 N·cm, the maximum stress value of the abutment screw was 573.9 MPa that is equivalent to 65% of Ti-6Al-4V yield strength. When the tightening torque was 30 N·cm, the maximum stress value of the abutment screw was 859.6 MPa that is similar to the Ti-6Al-4V yield strength. Conclusion: As the screw preload rose when applying each tightening torque to the custom-abutment implant system, the equivalent stress increased. It was found that the tightening torque of the abutment influenced the abutment-fixture connection interface stability. The analysis results indicate that a custom-abutment implant system should closely consider the optimal tightening torque according to clinical functional loads.

키워드

과제정보

This paper was supported by grant from Catholic University of Pusan, 2021.

참고문헌

  1. Rieder CE. Customized implant abutment copings to achieve biologic, mechanical, and esthetic objectives. Int J Periodontics Restorative Dent. 1996;16:20-29.
  2. Heydecke G, Sierraalta M, Razzoog ME. Evolution and use of aluminum oxide single-tooth implant abutments: a short review and presentation of two cases. Int J Prosthodont. 2002;15:488-493.
  3. Wu T, Liao W, Dai N, Tang C. Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis. J Biomech. 2010;43:1941-1946. https://doi.org/10.1016/j.jbiomech.2010.03.017
  4. Grossmann Y, Pasciuta M, Finger IM. A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration. J Prosthet Dent. 2006;95:258-261. https://doi.org/10.1016/j.prosdent.2005.12.013
  5. Winkler S, Ring K, Ring JD, Boberick KG. Implant screw mechanics and the settling effect: overview. J Oral Implantol. 2003;29:242-245. https://doi.org/10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2
  6. Alkan I, Sertgoz A, Ekici B. Influence of occlusal forces on stress distribution in preloaded dental implant screws. J Prosthet Dent. 2004;91:319-325. https://doi.org/10.1016/j.prosdent.2004.01.016
  7. Wang RF, Kang B, Lang LA, Razzoog ME. The dynamic natures of implant loading. J Prosthet Dent. 2009;101:359-371. https://doi.org/10.1016/S0022-3913(09)60079-2
  8. Karaman T, Kahraman OE. Comparison of reverse torque in different types of implant screw systems. J Int Dent Med Res. 2020;13:101-105.
  9. Seddigh MA, Mostafavi AS. Implant abutment screw loosening: a review of effective factors. JCDR. 2019;13:ZE06-ZE09.
  10. Huang Y, Wang J. Mechanism of and factors associated with the loosening of the implant abutment screw: a review. J Esthet Restor Dent. 2019;31:338-345. https://doi.org/10.1111/jerd.12494
  11. Zembic A, Philipp AO, Hammerle CH, Wohlwend A, Sailer I. Eleven-year follow-up of a prospective study of zirconia implant abutments supporting single all-ceramic crowns in anterior and premolar regions. Clin Implant Dent Relat Res. 2015;17 Suppl 2:e417-e426. https://doi.org/10.1111/cid.12263
  12. Jorn D, Kohorst P, Besdo S, Rucker M, Stiesch M, Borchers L. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant. J Prosthet Dent. 2014;112:340-348. https://doi.org/10.1016/j.prosdent.2013.10.016
  13. Kayabasi O, Ekici B. The effects of static, dynamic and fatigue behavior on three-dimensional shape optimization of hip prosthesis by finite element method. Mater Des. 2007;28:2269-2277. https://doi.org/10.1016/j.matdes.2006.08.012
  14. Verplancke K, De Waele W, De Bruyn H. Dental implants, what should be known before starting an in vitro study. Int J Sustain Constr Des. 2011;2:360-369.
  15. Wu YL, Tsai MH, Chen HS, Chang YT, Lin TT, Wu AY. Biomechanical effects of original equipment manufacturer and aftermarket abutment screws in zirconia abutment on dental implant assembly. Sci Rep. 2020;10:18406. https://doi.org/10.1038/s41598-020-75469-9
  16. Akca K, Cehreli MC, Iplikcioglu H. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res. 2003;14:444-454. https://doi.org/10.1034/j.1600-0501.2003.00828.x
  17. Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992;7:353-359.
  18. English CE. Externally hexed implants, abutments, and transfer devices: a comprehensive overview. Implant Dent. 1992;1:273-282. https://doi.org/10.1097/00008505-199200140-00009
  19. Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants. 1989;4:241-247.
  20. Bulaqi HA, Mousavi Mashhadi M, Safari H, Samandari MM, Geramipanah F. Dynamic nature of abutment screw retightening: finite element study of the effect of retightening on the settling effect. J Prosthet Dent. 2015;113:412-419. https://doi.org/10.1016/j.prosdent.2014.09.017
  21. Hotinski E, Dudley J. Abutment screw loosening in angulation-correcting implants: an in vitro study. J Prosthet Dent. 2019;121:151-155. https://doi.org/10.1016/j.prosdent.2018.03.005
  22. Jung WK, Lee WS, Kwon HB. Effects of abutment screw preload in two implant connection systems: a 3D finite element study. J Prosthet Dent. 2019;122:474.e1-474.e8. https://doi.org/10.1016/j.prosdent.2019.04.025
  23. Versluis A, Korioth TW, Cardoso AC. Numerical analysis of a dental implant system preloaded with a washer. Int J Oral Maxillofac Implants. 1999;14:337-341.
  24. Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants. 1995;10:295-302.
  25. Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent. 2003;90:539-546. https://doi.org/10.1016/j.prosdent.2003.09.012
  26. Bulaqi HA, Barzegar A, Paknejad M, Safari H. Assessment of preload, remaining torque, and removal torque in abutment screws under different frictional conditions: a finite element analysis. J Prosthet Dent. 2019;121:548.e1-548.e7. https://doi.org/10.1016/j.prosdent.2018.10.035
  27. McGlumphy EA. Keeping implant screws tight: the solution. J Dent Symp. 1993;1:20-23.
  28. Lemos CA, de Souza Batista VE, Almeida DA, Santiago Junior JF, Verri FR, Pellizzer EP. Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss: a systematic review and meta-analysis. J Prosthet Dent. 2016;115:419-427. https://doi.org/10.1016/j.prosdent.2015.08.026
  29. Liu YJ, Cui SM, He C, Li JK, Wang QY. High cycle fatigue behavior of implant Ti-6Al-4V in air and simulated body fluid. Biomed Mater Eng. 2014;24:263-269.