Abstract

Many Korean domestic masonry structures constructed since 1970 have been found to be vulnerable to earthquakes because they lack efficient lateral force resistance. Many studies have shown that the brick and mortar suddenly experience brittle fracture and out-of-plane collapse when they reach the inelastic range. This study evaluated the seismic retrofitting of non-reinforced masonry with Hybrid Super Coating (HSC) and Cast, manufactured using glass fiber. Four types of specimen original specimen (BR-OR), one layered HSC (BR-HS-O), two-layered HSC (BR-HS-B), one layered HSC, and Cast (BR-CT-HS-O) were constructed and analyzed using compression, flexural tensile, diagonal compression, and triplet tests. The specimen responses were presented and discussed in load-displacement curves, maximum strength, and crack propagation. The compressive strength of the retrofit specimens slightly increased, while the flexural tensile strength of the retrofit specimens increased significantly. In addition, the HSC and Cast also produced a considerable increase in the ductile response of specimens before failure. Diagonal compression test results showed that HSC delayed brittle cracks between the mortar and bricks and resulted in larger displacement before failure than the original brick. The triplet test results confirmed that the bonding strength of the retrofit specimens also increased. The application of HSC and Cast was found to restrain the occurrence of brittle failure effectively and delayed the collapse of masonry wall structures.

Keywords

Acknowledgement

본 연구는 정부(과학기술정보통신부)의 재원으로 한국연구재단(NRF-2020R1A2C2007195) 및 (주)에이톰엔지니어링의 지원을 받아 수행된 연구임.

References

  1. Statistics KOREA Government Official Work Conference[Internet]. 2020.03 [cited 2007 Jan 8]; Available from: http://www.index.go.kr/potal/main/EachDtlPageDetail.do?idx_cd=1226
  2. Chang KK, Seo DW. Present State and Necessity of Seismic Design for Low-rise Masonry Buildings in Korea. Journal of the Architectural Institute of Korea. 2011;55(5):45-50.
  3. Yu E. Seismic Performance and Retrofit of Masonry-infilled Frames. Magazine of the Korea Concrete Institute. 2015;27(6):41-45. https://doi.org/10.22636/MKCI.2015.27.6.41
  4. Pavan GS, Nanjunda Rao KS. Behavior of brick-mortar interfaces in FRP-strengthened masonry assemblages under normal loading and shear loading. Journal of Materials in Civil Engineering. 2016;28(2):04015120. https://doi.org/10.1061/(ASCE)MT.1943-5533.0001388
  5. Messali F, Metelli G, Plizzari G. Experimental results on the retrofitting of hollow brick masonry walls with reinforced high performance mortar coatings. Construction and Building Materials. 2017;141:619-630. https://doi.org/10.1016/j.conbuildmat.2017.03.112
  6. Valluzzi MR, Tinazzi D, Modena C. Shear behavior of masonry panels strengthened by FRP laminates. Construction and Building Materials. 2002;16(7):409-416. https://doi.org/10.1016/S0950-0618(02)00043-0
  7. Gams M, Tomazevic M, Berset T. Seismic strengthening of brick masonry by composite coatings: An experimental study. Bulletin of Earthquake Engineering. 2017;15.10:4269-4298. https://doi.org/10.1007/s10518-017-0136-4
  8. ElGawady MA, Lestuzzi P, Badoux M. Retrofitting of masonry walls using shotcrete. In: 2006 NZSEE Conference, Paper. c2006.
  9. Tomazevic M. Earthquake-resistant design of masonry buildings (Vol. 1). World Scientific. c1999.
  10. Vega C, Torres N. External strengthening of unreinforced masonry walls with polymers reinforced with carbon fiber. Ingenieria e Investigacion. 2018;38(3):15-23. https://doi.org/10.15446/ing.investig.v38n3.73151
  11. Kim HC, Kim KJ, Park JH, Hong WK. Experimental Study on the Material Properties of Unreinforced Masonry Considering Earthquake Load. Journal of the Earq uake Engineering Society of Korea. 2001;5(2):93-101.
  12. Lee JH. Seismic Capacity and Seismic Retrofitting of Low Rise Buildings - Unreinforced Masonry, Brick-Infilled RC Frame and Steel Slit Damper Retrofitted RC Frame. Ph.D. Thesis, University of Kwangwoon. c2005
  13. Yu E, Kim MJ, Lee SH, Kim CM. Relation between Shear Strength of Masonry infills and Seismic Performance of Masonry-infilled Frames. Journal of the Earthquake Engineering Society of Korea. 2015;19(4):173-181. https://doi.org/10.5000/EESK.2015.19.4.173
  14. Yu HR, Kwon KH. A study on mechanical characteristics of masonry structure constructed by clay brick with lime mortar. Journal of the Korea Institute for Structural Maintenance and Inspection. 2011;15(4):87-98. https://doi.org/10.11112/jksmi.2011.15.4.087
  15. Korea Infrastructure Safety Corporation. Guidelines for Evaluating Seismic Performance of Existing Building. 2019:96-98
  16. Korean Standards Association. KS F 4004. Concrete bricks. Korea Standard Association. c2013.
  17. Korean Standards Association. KS L 510 5: Testing Method for Compressive Strength of Hydraulic Cement Mortars. Korean Standards Association. c2017.
  18. Korean Standards Association. KS L 5220. Dry ready mixed cement mortar. Korea Standard Association. c2018.
  19. ASTM International. ASTM C 1314-12 Standard Test Method for Compressive Strength of Masonry Prisms. ASTM International, West Conshohocken, PA. c2012.
  20. ASTM International. ASTM E518/ E518M-10 Standard Test Methods for Flexural Bond Strength of Masonry. ASTM International, West Conshohocken, PA. c2010.
  21. ASTM International. ASTM E 519/E 519M-10 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages. ASTM International, West Conshohocken, PA. c2010.
  22. BS EN 1052-3 Methods of test for masonry-Part 3: Determination of initial shear strength. c2002.
  23. Yi WH, Lee JH, Oh SH, Yang WJ, Kang DE. A study on evaluation of shear capacity of unreinforced masonry wall. Journal of Architectural Institute of Korea. 2005;21(10):3-10.
  24. Park BT, Kwon KH. Seismic Performance Evaluation of Masonry Infilled Wall With Non-seismic Detail. Journal of the Korean Society of Safety. 2017;32(1):66-74. https://doi.org/10.14346/JKOSOS.2017.32.1.66
  25. Han SS, Kang THK. A Study on Seismic Performance of Masonry-infilled Reinforced Concrete Frames Retrofitted with High-performance Materials. Journal of the Korea Concrete Institute. 2019;31(5):449-458. https://doi.org/10.4334/jkci.2019.31.5.449