DOI QR코드

DOI QR Code

Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments

  • 투고 : 2020.07.19
  • 심사 : 2020.12.24
  • 발행 : 2021.05.31

초록

Objectives: This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems. Materials and Methods: Two hundred simulated canals were instrumented using Reciproc Blue and WaveOne Gold. Each file was used up to 10 times or until fracture. The instrumented area was measured in pre- and post-operative images, using ImageJ software. Kaplan-Meier survival analysis evaluated the number of uses of instruments before fracture. Instrumented area and time of instrumentation were analyzed by Mann-Whitney U test and Kruskal-Wallis. Correlations among the number of uses and instrumented area were measured. The level of statistical significance was set at p < 0.05. Results: Reciproc Blue presented a higher estimated number of uses in comparison with WaveOne Gold (p = 0.026), but autoclaving did not affect the resistance to fracture of instruments (p > 0.05). The instrumented area was different among the evaluated groups (p = 0.039), and the instrumented area along the uses of both tested instruments was reduced. With the time of instrumentation, there was also a significant difference among the evaluated groups; the groups without sterilization cycles were faster, in comparison to those submitted to autoclaving (p = 0.010). Conclusions: Reciproc Blue was more resistant than WaveOne Gold, suffering later fracture. Additionally, the sterilization cycles did not influence the estimated number of uses of thermally treated reciprocating instruments, but the instrumented area of root canals was reduced along with the repeated uses of both instruments.

키워드

과제정보

The research received financial support from CNPq Grant - PIBIC (V.O.P.).

참고문헌

  1. Hasheminia SM, Farhad A, Sheikhi M, Soltani P, Hendi SS, Ahmadi M. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems. J Endod 2018;44:1788-1791. https://doi.org/10.1016/j.joen.2018.09.011
  2. Abu-Tahun IH, Kwak SW, Ha JH, Kim HC. Microscopic features of fractured fragment of nickel-titanium endodontic instruments by two different modes of torsional loading. Scanning 2018;2018:9467059.
  3. Es-Souni M, Es-Souni M, Brandies HF. On the transformation behaviour, mechanical properties and biocompatibility of two NiTi-based shape memory alloys: NiTi42 and NiTi42Cu7. Biomaterials 2001;22:2153-2161. https://doi.org/10.1016/S0142-9612(00)00406-3
  4. Zupanc J, Vahdat-Pajouh N, Schafer E. New thermomechanically treated NiTi alloys - a review. Int Endod J 2018;51:1088-1103. https://doi.org/10.1111/iej.12924
  5. Kiefner P, Ban M, De-Deus G. Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments? Int Endod J 2014;47:430-436. https://doi.org/10.1111/iej.12166
  6. Silva EJNL, Vieira VTL, Hecksher F, Dos Santos Oliveira MRS, Dos Santos Antunes H, Moreira EJL. Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig 2018;22:2633-2638. https://doi.org/10.1007/s00784-018-2362-9
  7. Yamazaki-Arasaki A, Cabrales R, Santos Md, Kleine B, Prokopowitsch I. Topography of four different endodontic rotary systems, before and after being used for the 12th time. Microsc Res Tech 2012;75:97-102. https://doi.org/10.1002/jemt.21021
  8. Silva EJNL, Zanon M, Hecksher F, Belladonna FG, de Vasconcelos RA, Fidalgo TKDS. Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review. Restor Dent Endod 2020;45:e25.
  9. Bueno CSP, Oliveira DP, Pelegrine RA, Fontana CE, Rocha DGP, Bueno CEDS. Fracture incidence of WaveOne and Reciproc files during root canal preparation of up to 3 posterior teeth: a prospective clinical study. J Endod 2017;43:705-708. https://doi.org/10.1016/j.joen.2016.12.024
  10. Bueno CSP, Oliveira DP, Pelegrine RA, Fontana CE, Rocha DGP, Gutmann JL, Bueno CES. Fracture incidence of WaveOne Gold files: a prospective clinical study. Int Endod J 2020;53:1192-1198. https://doi.org/10.1111/iej.13349
  11. Duque JA, Bramante CM, Duarte MAH, Alcalde MP, Silva EJNL, Vivan RR. Cyclic fatigue resistance of nickel-titanium reciprocating instruments after simulated clinical use. J Endod 2020 Aug 18. doi: 10.1016/j.joen.2020.08.010. [Epub ahead of print].
  12. Spicciarelli V, Corsentino G, Ounsi HF, Ferrari M, Grandini S. Shaping effectiveness and surface topography of reciprocating files after multiple simulated uses. J Oral Sci 2019;61:45-52. https://doi.org/10.2334/josnusd.17-0311
  13. Barros SGO, de Lima CO, Vieira VTL, Neves AA, Accorsi-Mendonca T, da Silva EJNL. Bending resistance and quantitative transportation assessment after multiple uses of a reciprocating instrument. Endod Pract Today 2018;12:251-256. 
  14. Ozyurek T, Yilmaz K, Uslu G. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments. Restor Dent Endod 2017;42:301-308. https://doi.org/10.5395/rde.2017.42.4.301
  15. Di Nardo D, Miccoli G, Mazzoni A, Seracchiani M, Gambarini G, Testarelli L. Centering ability of a new nickel-titanium rotary instruments with a peculiar flat-side design: an in vitro study. J Contemp Dent Pract 2020;21:539-542. https://doi.org/10.5005/jp-journals-10024-2829
  16. Campanella V, Gianni L, Libonati A, Gallusi G. Shaping ability of Reciproc R25 file and Mtwo system used in continuous and reciprocating motion. J Contemp Dent Pract 2020;21:171-177. https://doi.org/10.5005/jp-journals-10024-2760
  17. Alfadley A, Alrajhi A, Alissa H, Alzeghaibi F, Hamadah L, Alfouzan K, Jamleh A. Shaping ability of XP Endo Shaper file in curved root canal models. Int J Dent 2020;2020:4687045.
  18. Silva EJ, Tameirao MD, Belladonna FG, Neves AA, Souza EM, De-Deus G. Quantitative transportation assessment in simulated curved canals prepared with an adaptive movement system. J Endod 2015;41:1125-1129. https://doi.org/10.1016/j.joen.2015.02.028
  19. Coleman CL, Svec TA. Analysis of Ni-Ti versus stainless steel instrumentation in resin simulated canals. J Endod 1997;23:232-235. https://doi.org/10.1016/S0099-2399(97)80053-2
  20. You SY, Kim HC, Bae KS, Baek SH, Kum KY, Lee W. Shaping ability of reciprocating motion in curved root canals: a comparative study with micro-computed tomography. J Endod 2011;37:1296-1300. https://doi.org/10.1016/j.joen.2011.05.021
  21. Gavini G, Caldeira CL, Akisue E, Candeiro GT, Kawakami DA. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. J Endod 2012;38:684-687. https://doi.org/10.1016/j.joen.2011.12.033
  22. Pirani C, Paolucci A, Ruggeri O, Bossu M, Polimeni A, Gatto MR, Gandolfi MG, Prati C. Wear and metallographic analysis of WaveOne and reciproc NiTi instruments before and after three uses in root canals. Scanning 2014;36:517-525. https://doi.org/10.1002/sca.21150
  23. Cunha RS, Junaid A, Ensinas P, Nudera W, Bueno CE. Assessment of the separation incidence of reciprocating WaveOne files: a prospective clinical study. J Endod 2014;40:922-924. https://doi.org/10.1016/j.joen.2014.03.016
  24. Ozyurek T, Gundogar M, Uslu G, Yilmaz K, Staffoli S, Nm G, Plotino G, Polimeni A. Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals. Odontology 2018;106:408-413. https://doi.org/10.1007/s10266-018-0340-y
  25. Plotino G, Costanzo A, Grande NM, Petrovic R, Testarelli L, Gambarini G. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod 2012;38:222-225. https://doi.org/10.1016/j.joen.2011.10.017
  26. Zhao D, Shen Y, Peng B, Haapasalo M. Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated nickel-titanium instruments. Int Endod J 2016;49:990-995. https://doi.org/10.1111/iej.12550
  27. Champa C, Divya V, Srirekha A, Karale R, Shetty A, Sadashiva P. An analysis of cyclic fatigue resistance of reciprocating instruments in different canal curvatures after immersion in sodium hypochlorite and autoclaving: an in vitro study. J Conserv Dent 2017;20:194-198. https://doi.org/10.4103/0972-0707.218307
  28. Kowalczuck A, Sydney GB, Martinez EF, Cardoso RJ. Evaluation of cutting ability and plastic deformation of reciprocating files. Braz Oral Res 2016;30:1-6.
  29. Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. Int Endod J 1985;18:240-246. https://doi.org/10.1111/j.1365-2591.1985.tb00450.x
  30. Saber SEDM, Nagy MM, Schafer E. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth. Int Endod J 2015;48:109-114. https://doi.org/10.1111/iej.12289
  31. Burklein S, Fluch S, Schafer E. Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue. Odontology 2019;107:96-102. https://doi.org/10.1007/s10266-018-0364-3