과제정보
This work was supported by the 2017 Inje University research grant.
참고문헌
- Li G, Ballangrud A, Kuo LC, Kang H, Kirov A, Lovelock M, et al. Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging. Med Phys. 2011;38:3981-3994. https://doi.org/10.1118/1.3596526
- Tagaste B, Riboldi M, Spadea MF, Bellante S, Baroni G, Cambria R, et al. Comparison between infrared optical and stereoscopic X-ray technologies for patient setup in image guided stereotactic radiotherapy. Int J Radiat Oncol Biol Phys. 2012;82:1706-1714. https://doi.org/10.1016/j.ijrobp.2011.04.004
- Wang LT, Solberg TD, Medin PM, Boone R. Infrared patient positioning for stereotactic radiosurgery of extracranial tumors. Comput Biol Med. 2001;31:101-111. https://doi.org/10.1016/S0010-4825(00)00026-3
- Schipani S, Wen W, Jin JY, Kim JK, Ryu S. Spine radiosurgery: a dosimetric analysis in 124 patients who received 18 Gy. Int J Radiat Oncol Biol Phys. 2012;84:e571-e576. https://doi.org/10.1016/j.ijrobp.2012.06.049
- Wu VW, Ho YY, Tang YS, Lam PW, Yeung HK, Lee SW. Comparison of the verification performance and radiation dose between ExacTrac x-ray system and On-Board Imager-a phantom study. Med Dosim. 2019;44:15-19. https://doi.org/10.1016/j.meddos.2017.12.008
- Murphy MJ, Balter J, Balter S, BenComo JA Jr, Das IJ, Jiang SB, et al. The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. Med Phys. 2007;34:4041-4063. https://doi.org/10.1118/1.2775667
- Cheng CS, Jong WL, Ung NM, Wong JHD. Evaluation of imaging dose from different image guided systems during head and neck radiotherapy: a phantom study. Radiat Prot Dosimetry. 2017;175:357-362.
- Steiner E, Stock M, Kostresevic B, Ableitinger A, Jelen U, Prokesch H, et al. Imaging dose assessment for IGRT in particle beam therapy. Radiother Oncol. 2013;109:409-413. https://doi.org/10.1016/j.radonc.2013.09.007
- Hoisak JDP, Pawlicki T. The role of optical surface imaging systems in radiation therapy. Semin Radiat Oncol. 2018;28:185-193. https://doi.org/10.1016/j.semradonc.2018.02.003
- Freislederer P, Kugele M, Ollers M, Swinnen A, Sauer TO, Bert C, et al. Recent advanced in surface guided radiation therapy. Radiat Oncol. 2020;15:187. https://doi.org/10.1186/s13014-020-01629-w
- Li J, Shi W, Andrews D, Werner-Wasik M, Lu B, Yu Y, et al. Comparison of online 6 degree-of-freedom image registration of Varian TrueBeam cone-beam CT and BrainLab ExacTrac X-ray for intracranial radiosurgery. Technol Cancer Res Treat. 2017;16:339-343. https://doi.org/10.1177/1533034616683069
- Laaksomaa M, Sarudis S, Rossi M, Lehtonen T, Pehkonen J, Remes J, et al. AlignRT® and CatalystTM in whole-breast radiotherapy with DIBH: is IGRT still needed? J Appl Clin Med Phys. 2019;20:97-104. https://doi.org/10.1002/acm2.12553
- Agazaryan N, Tenn S, Dieterich S, Gevaert T, Goetsch SJ, Kaprealian T. Frameless image guidance in stereotactic radiosurgery. Stereotactic and Functional Neurosurgery. Cham: Springer; 2020:37-48.
- Manger RP, Paxton AB, Pawlicki T, Kim GY. Failure mode and effects analysis and fault tree analysis of surface image guided cranial radiosurgery. Med Phys. 2015;42:2449-2461. https://doi.org/10.1118/1.4918319
- Gilles M, Fayad H, Miglierini P, Clement JF, Scheib S, Cozzi L, et al. Patient positioning in radiotherapy based on surface imaging using time of flight cameras. Med Phys. 2016;43:4833. https://doi.org/10.1118/1.4959536
- Padilla L, Pearson EA, Pelizzari CA. Collision prediction software for radiotherapy treatments. Med Phys. 2015;42:6448-6456. https://doi.org/10.1118/1.4932628
- Hoole AC, Twyman N, Langmack KA, Hebbard M, Lowrie D. Laser scanning of patient outlines for three-dimensional radiotherapy treatment planning. Physiol Meas. 2001;22:605-610. https://doi.org/10.1088/0967-3334/22/3/316
- Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, et al. Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system. Acta Neurochir (Wien). 1997;139:551-559. https://doi.org/10.1007/BF02750999
- Kosugi Y, Watanabe E, Goto J, Watanabe T, Yoshimoto S, Takakura K, et al. An articulated neurosurgical navigation system using MRI and CT images. IEEE Trans Biomed Eng. 1988;35:147-152. https://doi.org/10.1109/10.1353
- Fan Y, Jiang D, Wang M, Song Z. A new markerless patientto-image registration method using a portable 3D scanner. Med Phys. 2014;41:101910. https://doi.org/10.1118/1.4895847
- Giancola S, Valenti M, Sala R. A survey on 3D cameras: metrological comparison of time-of-flight, structuredlight and active stereoscopy technologies. Cham: Springer; 2018.
- He Y, Liang B, Yang J, Li S, He J. An iterative closest points algorithm for registration of 3D laser scanner point clouds with geometric features. Sensors (Basel). 2017;17:1862. https://doi.org/10.3390/s17081862
- Habib A, Detchev I, Bang K. A comparative analysis of two approaches for multiple-surface registration of irregular point clouds. Paper presented at: The 2010 Canadian Geomatics Conference and Symposium of Commission I; 2010 Jun 15-18; Calgary, Canada. p. 39.
- Rusu RB, Cousins S. 3D is here: Point Cloud Library (PCL). Paper presented at: 2011 IEEE International Conference on Robotics and Automation; 2011 May 9-13; Shanghai, China.
- Arun KS, Huang TS, Blostein SD. Least-squares fitting of two 3-D point sets. IEEE Trans Pattern Anal Mach Intell. 1987;PAMI-9:698-700. https://doi.org/10.1109/TPAMI.1987.4767965
- Ge Y, Maurer Jr CR, Fitzpatrick JM. Surface-based 3D image registration using the iterative closest-point algorithm with a closest-point transform Medical Imaging 1996: Image Processing. SPIE Digital Library; 1996:358-367.
- Wu ML, Chien JC, Wu CT, Lee JD. An augmented reality system using improved-iterative closest point algorithm for on-patient medical image visualization. Sensors (Basel). 2018;18:2505. https://doi.org/10.3390/s18082505
- Tehrani JN, O'Brien RT, Poulsen PR, Keall P. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm. Phys Med Biol. 2013;58:8517-8533. https://doi.org/10.1088/0031-9155/58/23/8517
- Huttenlocher DP, Klanderman GA, Rucklidge WJ. Comparing images using the Hausdorff distance. IEEE Trans Pattern Anal Mach Intell. 1993;15:850-863. https://doi.org/10.1109/34.232073
- Wang G, Li Z, Li G, Dai G, Xiao Q, Bai L, et al. Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy. Radiat Oncol. 2021;16:13. https://doi.org/10.1186/s13014-020-01729-7
- Covington EL, Popple RA. A low-cost method to assess the performance of surface guidance imaging systems at nonzero couch angles. Cureus. 2021;13:e14278.
- Chan A, Coutts B, Parent E, Lou E. Development and evaluation of CT-to-3D ultrasound image registration algorithm in vertebral phantoms for spine surgery. Ann Biomed Eng. 2021;49:310-321. https://doi.org/10.1007/s10439-020-02546-5
- Wang S, Sun HY, Guo HC, Du L, Liu TJ. Multi-view laser point cloud global registration for a single object. Sensors (Basel). 2018;18:3729. https://doi.org/10.3390/s18113729
- Li J, Zhou Q, Li X, Chen R, Ni K. An improved low-noise processing methodology combined with PCL for industry inspection based on laser line scanner. Sensors (Basel). 2019;19:3398. https://doi.org/10.3390/s19153398
- Liu W, Cheung Y, Sabouri P, Arai TJ, Sawant A, Ruan D. A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system. Med Phys. 2015;42:6564-6571. https://doi.org/10.1118/1.4933196
- Fan Y, Yao X, Hu T, Xu X. An automatic spatial registration method for image-guided neurosurgery system. J Craniofac Surg. 2019;30:e344-e350. https://doi.org/10.1097/SCS.0000000000005330
- Muralikrishnan B, Rachakonda P, Lee V, Shilling M, Sawyer D, Cheok G, et al. Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target. Meas Sci Technol. 2017;111:60-68.
- Maier-Hein L, Franz AM, dos Santos TR, Schmidt M, Fangerau M, Meinzer HP, et al. Convergent iterative closest-point algorithm to accomodate anisotropic and inhomogenous localization error. IEEE Trans Pattern Anal Mach Intell. 2011;34:1520-1532. https://doi.org/10.1109/TPAMI.2011.248
- Liu W. LiDAR-IMU time delay calibration based on iterative closest point and iterated sigma point Kalman filter. Sensors (Basel). 2017;17:539. https://doi.org/10.3390/s17030539
- Coroiu ADCA, Coroiu A. Interchangeability of Kinect and Orbbec sensors for gesture recognition. Paper presented at: 2018 IEEE 14th International Conference on Intelligent Computer Communication and Processing (ICCP); 2018 Sep 6-8; Cluj-Napoca, Romania. p. 309-315.
- Wiersma RD, Tomarken SL, Grelewicz Z, Belcher AH, Kang H. Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking. Med Phys. 2013;40:111712. https://doi.org/10.1118/1.4823757