- Yoon, B. I., "Nonstructural Elements Resulting From Pohang Earthquake and Direction of Future Seismic Design Nonstructural Elements", Review of Architecture and Building Science, Vol.62, No.4, pp.23~28, 2018
- Jeong, Y. S., Woo, T. R., & Kim, J. B., "Behavior Characteristics of Cast-in Anchor Channel Anchor Shape on Non-structural Members", Journal of the Korean Society for Advanced Composite Structures, Vol.11, No.3, pp.46~54, 2020, doi: 10.11004/kosacs.2020.11.3.046
- Kim, D. I., & Jong, W. Y., "Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities", Journal of the Korea Academia-Industrial cooperation Society, Vol.20, No.11, pp.250~258, 2019, doi: 10.5762/KAIS.2019.20.11.250
- Lee, J. H. (2015). Evaluation of Shear Resistance of CIP Anchors in Concrete Using Seismic Simulation Tests. Proceedings of the Korea Concrete Institute, Republic of Korea, Vol.2015, No.5, pp.195~196
- Yun, S. Y., & Park, J. H., "An Experimental Study on the Tension Behaviour of Post-Installed Anchors for Seismic Retrofit", Journal of the Architectural Institute of Korea Structure & Construction, Vol.31, No.3, pp.27~36, 2015, doi: https://doi.org/10.5659/JAIK_SC.2015.31.3.27
- Yun, S. Y., & Park, J. H., "An Experimental Study on the Shear Behaviour of Post-Installed Anchors for Seismic Retrofit", Journal of the Architectural Institute of Korea Structure & Construction, Vol.30, No.9, pp.41~51, 2014, doi: 10.5659/JAIK_SC.2014.30.9.41
- Lee, S. K., Kim, S. H., Yun, H. D., & Choi, W. C. (2017). A Parametric Study for Shear Behavior of Steel Stud anchors in Concrete wall. Program Book of 2017 Conference of the Korean Society for Advanced Composite Structures, Republic of Korea, pp.115~116
- Kim, S. Y., & Kim, K. S., "Evaluation of Concrete Cone Breakout Strength of Expansion Anchors", Journal of Korean Society of Steel Construction, Vol.15, No.6, pp.649~660, 2003, Retrieved from https://www.koreascience.or.kr/article/JAKO200310103439722.pdf
- Yoo, S. W., Jung, S. H., Kwak, K. S., & Lee, J. H., "Experimental Study on Pull Out Characteristics of Adhesive Anchor", Journal of Civil and Environmental Engineering Research, Vol.26, No.3A, pp.555~563, 2006
- HILTI, Products: Anchors and Fasteners: Wedge anchors: HST3-R, Retrieved from https://www.hilti.co.kr/c/CLS_FASTENER _7135/CLS_WEDGE_ANCHORS_7135/r3987999
- Ministry of Land, Infrastructure and Transport (MOLIT), "KDS 14 20 54", MOLIT, 2021.
- Korean Agency for Technology and Standards (KATS), "KS B ISO 898-1: Mechanical properties of fasteners made of carbon steel and alloy steel - Part 1: Bolts, screws and studs", KATS, 2018.
- American Concrete Institute (ACI). "Building Code Requirements for Structural Concrete (ACI 318M-19) and Commentary (318RM-19)", ACI, 2019.
- Grimsmo, E. L., Aalberg, A., Langseth, M., & Clausen, A. H., "Failure modes of bolt and nut assemblies under tensile loading", Journal of Constructional Steel Research, Vol.126, pp.15~25, 2016, doi: 10.1016/j.jcsr.2016.06.023