References
- Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010; 256: 32-61. https://doi.org/10.1148/radiol.10090908
- Behrendt FF, Bruners P, Keil S, Plumhans C, Mahnken AH, Das M, et al. Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom. Eur J Radiol 2010; 73: 688-693. https://doi.org/10.1016/j.ejrad.2009.01.008
- Chambers TP, Baron RL, Lush RM. Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients. Radiology 1994; 193: 513-517. https://doi.org/10.1148/radiology.193.2.7972770
- Chambers TP, Baron RL, Lush RM. Hepatic CT enhancement. Part II. Alterations in contrast material volume and rate of injection within the same patients. Radiology 1994; 193: 518-522. https://doi.org/10.1148/radiology.193.2.7972771
- Cohan RH, Dunnick NR, Leder RA, Baker ME. Extravasation of nonionic radiologic contrast media: efficacy of conservative treatment. Radiology 1990; 176: 65-67. https://doi.org/10.1148/radiology.176.1.2353113
- Fields EL, Robertson ID, Brown JC Jr. Optimization of contrast-enhanced multidetector abdominal computed tomography in sedated canine patients. Vet Radiol Ultrasound 2012; 53: 507-512. https://doi.org/10.1111/j.1740-8261.2012.01950.x
- Foley WD, Hoffmann RG, Quiroz FA, Kahn CE Jr, Perret RS. Hepatic helical CT: contrast material injection protocol. Radiology 1994; 192: 367-371. https://doi.org/10.1148/radiology.192.2.8029399
- Freeny PC, Gardner JC, vonIngersleben G, Heyano S, Nghiem HV, Winter TC. Hepatic helical CT: effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement. Radiology 1995; 197: 89-93. https://doi.org/10.1148/radiology.197.1.7568860
- Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW. Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 2000; 174: 1049-1053. https://doi.org/10.2214/ajr.174.4.1741049
- Hopper KD. With helical CT, is nonionic contrast a better choice than ionic contrast for rapid and large IV bolus injections? AJR Am J Roentgenol 1996; 166: 715. https://doi.org/10.2214/ajr.166.3.8623657
- Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS. Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 1997; 205: 269-271. https://doi.org/10.1148/radiology.205.1.9314997
- Irie T, Kajitani M, Yamaguchi M, Itai Y. Contrast-enhanced CT with saline flush technique using two automated injectors: how much contrast medium does it save? J Comput Assist Tomogr 2002; 26: 287-291. https://doi.org/10.1097/00004728-200203000-00022
- Kim DJ, Kim TH, Kim SJ, Kim DP, Oh CS, Ryu YH, et al. Saline flush effect for enhancement of aorta and coronary arteries at multidetector CT coronary angiography. Radiology 2008; 246: 110-115. https://doi.org/10.1148/radiol.2453061953
- Kishimoto M, Doi S, Shimizu J, Lee KJ, Iwasaki T, Miyake Y, et al. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate. Eur J Radiol 2010; 76: 135-139. https://doi.org/10.1016/j.ejrad.2009.05.018
- Lee CH, Goo JM, Bae KT, Lee HJ, Kim KG, Chun EJ, et al. CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model. Invest Radiol 2007; 42: 486-490. https://doi.org/10.1097/RLI.0b013e318032a9fe
- Megibow AJ, Jacob G, Heiken JP, Paulson EK, Hopper KD, Sica G, et al. Quantitative and qualitative evaluation of volume of low osmolality contrast medium needed for routine helical abdominal CT. AJR Am J Roentgenol 2001; 176: 583-589. https://doi.org/10.2214/ajr.176.3.1760583
- Orlandini F, Boini S, Iochum-Duchamps S, Batch T, Zhu X, Blum A. Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT. AJR Am J Roentgenol 2006; 187: 511-515. https://doi.org/10.2214/AJR.04.0942
- Pollard R, Puchalski S. CT Contrast media and applications. In: Schwarz T, Saunders J, editors. Veterinary computed tomography. Chichester: Wiley-Blackwell. 2011: 57-66.
- Schoellnast H, Tillich M, Deutschmann HA, Stessel U, Deutschmann MJ, Schaffler GJ, et al. Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT. Eur Radiol 2004; 14: 659-664. https://doi.org/10.1007/s00330-003-2085-3
- Schoellnast H, Tillich M, Deutschmann MJ, Deutschmann HA, Schaffler GJ, Portugaller HR. Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column. Invest Radiol 2004; 39: 20-26. https://doi.org/10.1097/01.rli.0000091841.45342.84