DOI QR코드

DOI QR Code

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University) ;
  • Takeshi Nakaura (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University) ;
  • Yasunori Nagayama (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University) ;
  • Hiroyuki Uetani (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University) ;
  • Osamu Ikeda (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University) ;
  • Yasuyuki Yamashita (Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University)
  • 투고 : 2020.05.25
  • 심사 : 2020.10.08
  • 발행 : 2021.06.01

초록

Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

키워드

참고문헌

  1. Capellades J, Puig J, Domenech S, Pujol T, Oleaga L, Camins A, et al. Is a pretreatment radiological staging system feasible for suggesting the optimal extent of resection and predicting prognosis in glioblastoma? An observational study. J Neurooncol 2018;137:367-377 https://doi.org/10.1007/s11060-017-2726-z
  2. Leung D, Han X, Mikkelsen T, Nabors LB. Role of MRI in primary brain tumor evaluation. J Natl Compr Canc Netw 2014;12:1561-1568 https://doi.org/10.6004/jnccn.2014.0156
  3. Lennartz S, Laukamp KR, Neuhaus V, Grosse Hokamp N, Le Blanc M, Maus V, et al. Dual-layer detector CT of the head: initial experience in visualization of intracranial hemorrhage and hypodense brain lesions using virtual monoenergetic images. Eur J Radiol 2018;108:177-183 https://doi.org/10.1016/j.ejrad.2018.09.010
  4. Kamalian S, Lev MH, Pomerantz SR. Dual-energy computed tomography angiography of the head and neck and related applications. Neuroimaging Clin N Am 2017;27:429-443 https://doi.org/10.1016/j.nic.2017.04.009
  5. Paul J, Bauer RW, Maentele W, Vogl TJ. Image fusion in dual energy computed tomography for detection of various anatomic structures--effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Eur J Radiol 2011;80:612-619 https://doi.org/10.1016/j.ejrad.2011.02.023
  6. Hsu CC, Kwan GN, Singh D, Pratap J, Watkins TW. Principles and clinical application of dual-energy computed tomography in the evaluation of cerebrovascular disease. J Clin Imaging Sci 2016;6:27
  7. Wu R, Watanabe Y, Satoh K, Liao YP, Takahashi H, Tanaka H, et al. Quantitative comparison of virtual monochromatic images of dual energy computed tomography systems: beam hardening artifact correction and variance in computed tomography numbers: a phantom study. J Comput Assist Tomogr 2018;42:648-654 https://doi.org/10.1097/RCT.0000000000000726
  8. Naruto N, Itoh T, Noguchi K. Dual energy computed tomography for the head. Jpn J Radiol 2018;36:69-80 https://doi.org/10.1007/s11604-017-0701-4
  9. Kamiya K, Kunimatsu A, Mori H, Sato J, Akahane M, Yamakawa T, et al. Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose. Jpn J Radiol 2013;31:293-298 https://doi.org/10.1007/s11604-013-0185-9
  10. Lin XZ, Miao F, Li JY, Dong HP, Shen Y, Chen KM. High-definition CT Gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr 2011;35:294-297 https://doi.org/10.1097/RCT.0b013e3182058d5c
  11. Kim SJ, Lim HK, Lee HY, Choi CG, Lee DH, Suh DC, et al. Dual-energy CT in the evaluation of intracerebral hemorrhage of unknown origin: differentiation between tumor bleeding and pure hemorrhage. AJNR Am J Neuroradiol 2012;33:865-872 https://doi.org/10.3174/ajnr.A2890
  12. Hwang WD, Mossa-Basha M, Andre JB, Hippe DS, Culbertson S, Anzai Y. Qualitative comparison of noncontrast head dual-energy computed tomography using rapid voltage switching technique and conventional computed tomography. J Comput Assist Tomogr 2016;40:320-325 https://doi.org/10.1097/RCT.0000000000000350
  13. Park J, Choi YH, Cheon JE, Kim WS, Kim IO, Pak SY, et al. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography. Pediatr Radiol 2017;47:1648-1658 https://doi.org/10.1007/s00247-017-3908-8
  14. Pomerantz SR, Kamalian S, Zhang D, Gupta R, Rapalino O, Sahani DV, et al. Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65-75 keV maximizes image quality compared with conventional polychromatic CT. Radiology 2013;266:318-325 https://doi.org/10.1148/radiol.12111604
  15. Hixson HR, Leiva-Salinas C, Sumer S, Patrie J, Xin W, Wintermark M. Utilizing dual energy CT to improve CT diagnosis of posterior fossa ischemia. J Neuroradiol 2016;43:346-352 https://doi.org/10.1016/j.neurad.2016.04.001
  16. Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 2011;38:6371-6379 https://doi.org/10.1118/1.3658568
  17. Nagayama Y, Nakaura T, Tsuji A, Urata J, Furusawa M, Yuki H, et al. Radiation dose reduction using 100-kVp and a sinogram-affirmed iterative reconstruction algorithm in adolescent head CT: impact on grey-white matter contrast and image noise. Eur Radiol 2017;27:2717-2725 https://doi.org/10.1007/s00330-016-4679-6
  18. Park JE, Choi YH, Cheon JE, Kim WS, Kim IO, Cho HS, et al. Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp. Pediatr Radiol 2017;47:710-717 https://doi.org/10.1007/s00247-017-3799-8
  19. Brooks RA, Di Chiro G, Keller MR. Explanation of cerebral white--gray contrast in computed tomography. J Comput Assist Tomogr 1980;4:489-491 https://doi.org/10.1097/00004728-198008000-00016
  20. Nagayama Y, Nakaura T, Oda S, Utsunomiya D, Funama Y, Iyama Y, et al. Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol. Eur Radiol 2018;28:1719-1730 https://doi.org/10.1007/s00330-017-5114-3
  21. Sellerer T, Noel PB, Patino M, Parakh A, Ehn S, Zeiter S, et al. Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol 2018;28:2745-2755 https://doi.org/10.1007/s00330-017-5238-5
  22. Bodanapally UK, Archer-Arroyo KL, Dreizin D, Shanmuganathan K, Schwartzbauer G, Li G, et al. Dual-energy computed tomography imaging of head: virtual high-energy monochromatic (190keV) images are more reliable than standard 120kV images for detecting traumatic intracranial hemorrhages. J Neurotrauma 2019;36:1375-1381 https://doi.org/10.1089/neu.2018.5985