DOI QR코드

DOI QR Code

Seismic performance evaluation of slotted-web and bolt-flange plate moment connection

  • Kolbadi, S. Mohammad S. (Department of Civil Engineering, Faculty of Structure and Architecture, Technical and Vocational University (TVU)) ;
  • Piri, Hosein (Department of Civil Engineering, Shahroud university of Technology) ;
  • Keyhani, Ali (Department of Civil Engineering, Shahroud university of Technology) ;
  • Kolbadi, S. Mahdi S. (Department of Civil Engineering, KNTU of technology) ;
  • Mirtaheri, Masoud (Department of Civil Engineering, KNTU of technology)
  • Received : 2020.06.15
  • Accepted : 2021.05.17
  • Published : 2021.06.25

Abstract

In this article, a steel moment connection of beam to the column called a slotted web and bolt flange plate moment connection is introduced and the seismic performance of the connection is assessed by modeling the finite element. The connection consists of two slots in the beam web and bolted plates to the beam flange at the area of connection of the beam to the column to create a plastic hinge in an area farther from the column face, thus reducing the plastic strain equivalent to the panel zone and welding the beam-to-column connection area. The beam is connected to the slab on the side so that no plastic hinge is created against the side buckling. A numerical study has been performed to find the effectiveness of the proposed connection parameters. The results showed that following the limitations in this study, the SW-BFP connection had better hysteresis behavior than the SW connection. The deformation capacity of the connection in the SW-BFP connection (slotted web and bolt flange plate moment connection) has increased up to 112% compared to the connection of the beam with the slot web (SW). The sheet bolted to the beam flange on both sides of the beam with the slot die causes the buckling modes to occur later and reduces the stress by 23.93% in the beam-to-column connection area and 20.94% in the connection panel zone compared to the SW connection. Also, adding bolt-to-beam plates to the SW connection reduces the plastic strain in the panel zone by 87%, while the strain value in the beam-to-column connection area has reached zero.

Keywords

Acknowledgement

The authors of the article state that they have not received any funding for this research.

References

  1. Abel, J.F. and Popov, E.P. (1968), "Static and dynamic finite element analysis of sandwich structures", Air Force Flight Dyn. Lab., 68(150), 213-245.
  2. Adlparvar, M.R., Vetr, M.G. and Ghaffari, F. (2017), "The importance of panel zone shear strength on seismic behavior of improved slotted-web beam connections", Int. J. Steel Struct., 17(1), 307-318. https://doi.org/10.1007/s13296-015-0024-1.
  3. AISC (2016), "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications", AISC/ANSI, American Institute of Steel Construction (AISC), Chicago, IL. (Includes 2018 supplement), 358-16
  4. Aslam, A., Nath, Y., Vijai, K. and Udhayasankar, S. (2005), "Numerical Studies on Slotted Beam-Column Connection", In Structures Congress, Metropolis and Beyond, 1-8. https://doi.org/10.1061/40753(171)171.
  5. Chen, C.C., Lu, C.A. and Lin, C.C. (2005), "Parametric study and design of rib-reinforced steel moment connections", Eng. Struct., 27(5), 699-708. https://doi.org/10.1016/j.engstruct.2004.12.007.
  6. Chen, S.J., Yeh, C.H. and Chu, J.M. (1996), "Ductile steel beamto-column connections for seismic resistance", J. Struct. Eng., 122(11), 1292-1299. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:11(1292).
  7. Chou, C.C., Tsai, K.C., Wang, Y.Y. and Jao, C.K. (2010), "Seismic rehabilitation performance of steel side plate moment connections", Earthq. Eng. Struct. Dyn., 39(1), 23-44. https://doi.org/10.1002/eqe.931.
  8. Dimakogianni, D., Dougka, G. and Vayas, I. (2015), "Seismic behavior of frames with innovative energy dissipation systems (FUSEIS1-2)", Eng. Struct., 6(5), 83-95. https://doi.org/10.1016/j.engstruct.2015.01.054.
  9. Fanaie, N., Kazerani, S. and Soroushnia, S. (2017), "Numerical study of slotted web drilled flange moment frame connection", Numrical Method Civil Eng., 1(3), 16-23. http://nmce.kntu.ac.ir/article-1-38-en.html.
  10. Federal Emergency Management Agency (FEMA) (2000), "Seismic Design Criteria for Steel Moment- Frame Structures", FEMA, 350-355.
  11. Fukumoto, Y. and Lee, G.C. (1991), "Stability and ductility of steel structures under cyclic loading", CRC press.
  12. Ghobadi, M., Ghassemieh, M., Mazroi, A. and Abolmaali, A. (2009), "Seismic performance of ductile welded connections using T-stiffener", J. Constr. Steel Res., 65(4), 766-775. https://doi.org/10.1016/j.jcsr.2008.05.007.
  13. Goswami, R. and Murty, C. (2009), "Externally reinforced welded I-beam-to-box-column seismic connection", J. Eng. Mech. 136 (1), 23-30. https://doi.org/10.1061/(ASCE)0733-9399(2010)136:1(23).
  14. Hedayat, A.A. and Celikag, M. (2009), "Post-Northridge connection with modified beam end configuration to enhance strength and ductility", J. Construct. Steel Res., 65(7), 1413-1430. https://doi.org/10.1016/j.jcsr.2009.03.007.
  15. Jalali, S., Banazadeh, M., Abolmaali, A. and Tafakori, E. (2012), "Probabilistic seismic demand assessment of steel moment frames with side-plate connections, Sci. Iran, 19(1), 27-40. https://doi.org/10.1016/j.scient.2011.11.036.
  16. Kang, C.H., Kim, Y.J., Shin, K.J. and Oh, Y.S. (2013), "Experimental investigation of composite moment connections with external stiffeners", Adv. Struct. Eng., 16(10), 1683. https://doi.org/10.1260%2F1369-4332.16.10.1683. https://doi.org/10.1260%2F1369-4332.16.10.1683
  17. Kang, C.H., Shin, K.J., Oh, Y.S. and Moon, T.S. (2001), "Hysteresis behavior of CFT column to H-beam connections with external T-stiffeners and penetrated elements", Eng. Struct., 23(9), 1194-1201. https://doi.org/10.1016/S0141-0296(00)00119-X.
  18. Krawinkler, H., Gupta, A., Medina, R. and Luco, N. (2000), "Development of loading histories for a testing of steel beam-to-column assemblies", Department of Civil & Env. Engineering, Stanford University (SAC), SAC Background Report SAC/BD- 00/10.
  19. Mao, C., Ricles, J., Lu, L.W. and Fisher, J. (2001), "Effect of local details on ductility of welded moment connections", J. Struct. Eng., 127(9), 1036-1044. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:9(1036).
  20. Mehrabian, A., Ali, T. and Haldar, A. (2009), "Nonlinear analysis of a steel frame. Nonlinear Analysis:", Theory, Methods Appl., 71(12), e616-e623. https://doi.org/10.1016/j.na.2008.11.092.
  21. Miller, D.K. (1998), "Lessons learned from the Northridge earthquake", Eng. Struct. 20(4-6), 249-260. https://doi.org/10.1016/S0141-0296(97)00031-X.
  22. Nakashima, M., Inoue, K. and Tada, M. (1998), "Classification of damage to steel buildings observed in the 1995 Hyogoken-Nanbu earthquake", Eng. Struct. 20(4-6), 271-281. https://doi.org/10.1016/S0141-0296(97)00019-9.
  23. Partridge, J.E., Allen, J. and Richard, R.M. (2002), "Failure analysis of structural steel connections in the northridge and Loma Prieta earthquakes", Proceedings of the Seventh U.S. National Conference on Earthquake Engineering, ST50/ST-11, July.
  24. RCSC Committee (2004), "Specification for structural joints using ASTM A325 or A490 Bolts. AISC Inc.", Chicago, Illinois, U.S.A.
  25. Richard, R.M., Allen, C.J. and Partridge, C.E. (1997a), "Proprietary Slotted Beam Connections Designs", J. Modern Steel Construct., 28-33.
  26. Richard, R.M., Allen, C.J. and Partridge, C.E., (1997b), "Steel Frame Stress Reduction Connection", United State Patent Application Publication.
  27. Richard, R.M., Partridge, J.E. and Allen, J. (2001), "Accumulated Seismic Connection Damage Based upon Full Scale Low Cycle Fatigue Connection Tests", Proceedings of the Structural Engineers Association of California 70th Annual Convention, September.
  28. Ricles, J.M., Mao, C., Lu, L.W. and Fisher, J.W., (2002), "Inelastic cyclic testing of welded unreinforced moment connections", J. Struct. Eng., 128(4), 429-440. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(429).
  29. Seyed Kolbadi, S.M., Piri, H., Keyhani, A., Seyed-Kolbadi, S.M. and Mirtaheri, M. (2020), "Nonlinear seismic performance evaluation of flexural slotted connection using endurance time method", Shock Vib., 1(1), 1-15. https://doi.org/10.1155/2020/8842230.
  30. Seyed Kolbadi, S.M., Safi, M., Keshmiri, A., Seyed-Kolbadi, S.M. and Mirtaheri, M. (2021), "Vulnerability and reliability evaluation of steel and concrete structures under the action of strong earthquakes", Advan. Civil Eng., 1(1), 1-15.
  31. Shiravand, M. and Deylami, A. (2010), "Application of full depth side plate to moment connection of I-beam to double-I column", Adv. Struct. Eng., 13(6), 1047-1062. https://doi.org/10.1260%2F1369-4332.13.6.1047. https://doi.org/10.1260%2F1369-4332.13.6.1047
  32. Vetr, M.G. (2015), "Effect of vertical flange stiffener on the ductility of slotted web exclusive connection on (I)-shape profiles through experimental investigation", J. Eng. Res., 3(4). http://dx.doi.org/10.7603%2Fs40632-015-0034-3. https://doi.org/10.7603%2Fs40632-015-0034-3
  33. Yu, Q.S.K., Uang, C.M. and Gross, J. (2000), "Seismic rehabilitation design of steel moment connection with welded haunch", J. Struct. Eng., 126(1), 69-78. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:1(69).
  34. Yu, Y.Y. (1959), "A new theory of elastic sandwich plates-one dimensional case", J. Appl. Mech., 26(3), 415-423. https://doi.org/10.1115/1.4012054