Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia (School of Computing, Engineering & Mathematics, University of Western Sydney (UWS)) ;
  • Shil, Sukanta Kumer (School of Engineering and Information Technology, the University of New South Wales) ;
  • Rashed, M.G. (School of Engineering and Information Technology, the University of New South Wales) ;
  • Wilkins, Kathryn (School of Computing, Engineering & Mathematics, University of Western Sydney (UWS))
  • Received : 2019.10.14
  • Accepted : 2021.05.10
  • Published : 2021.06.10

Abstract

Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

Keywords

References

  1. AS/NZS 1554.2 (2003), Structural steel welding Stud welding (steel studs to steel), Standards Australia, SAI global, NSW Sydney Australia.
  2. ENV 1992-1-1 (2004), British Standards Institution. Design of concrete structures, Part 1.1 General rules and rules for buildings, London.
  3. Eurocode 4 1994-1-1 (2005), British Standards Institution EC4, London.
  4. ENV 1993-1-1 (2005), Design of the steel structures, Part 1.1 General rules and rules for buildings, Vol. ENV 1993-1-1 British Standard Institute, London.
  5. Australian Standard 1252 (1996), High Strength Steel Bolts with Associated Nuts and Washers for Stuctural Engineering, Sydney Australia.
  6. Baloch, W.L., Khushnood, R.A. and Khaliq, W. (2018), "Influence of multi-walled carbon nanotubes on the residual performance of concrete exposed to high temperatures", J. Constr. Build. Mater., 185, 44-56. https://doi.org/10.1016/j.conbuildmat.2018.07.051.
  7. Carreira, D.J. and Chu, K.H. (1985), "Stress-strain relationship for plain concrete in compression", J. Proceedings.
  8. Davoodnabi, S.M., Mirhosseini, S.M., Shariati, M.J.S. and Structures, C. (2019), "Behavior of steel-concrete composite beam using angle shear connectors at fire condition", Steel Compos. Struct., 30(2), 141-147. https://doi.org/10.12989/scs.2019.30.2.141.
  9. Delgado, J.L., Herranz, M.A. and Martin, N. (2008), "The nano-forms of carbon", J. Mater. Chem., 18(13), 1417-1426. https://doi.org/10.1039/B717218D.
  10. Fakury, R., Las Casas, E., F Jr, F.P. and Abreu, L. (2005), "Design of semi-continuous composite steel-concrete beams at the fire limit state", J. Constr. Steel Res., 61(8), 1094-1107. https://doi.org/10.1016/j.jcsr.2005.02.003.
  11. Galambos, T.V. (2000), "Recent research and design developments in steel and composite steel-concrete structures in USA", J. Constr. Steel Res., 55(1-3), 289-303. https://doi.org/10.1016/S0143-974X(99)00090-5.
  12. Gardner, L., Insausti, A., Ng, K. and Ashraf, M. (2010), "Elevated temperature material properties of stainless steel alloys", J. Constr. Steel Res., 66(5), 634-647. https://doi.org/10.1016/j.jcsr.2009.12.016.
  13. Han, Q., Wang, Y., Xu, J., Xing, Y. and Yang, G. (2017), "Numerical analysis on shear stud in push-out test with crumb rubber concrete", J. Constr. Steel Res., 130, 148-158. https://doi.org/10.1016/j.jcsr.2016.12.008.
  14. Huang, Z. (2010), "Modelling the bond between concrete and reinforcing steel in a fire", Eng. Struct., 32(11), 3660-3669. https://doi.org/10.1016/j.engstruct.2010.08.010.
  15. Lam, D. and El-Lobody, E. (2005), "Behavior of headed stud shear connectors in composite beam", J. Struct. Eng., 131(1), 96-107. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:1(96).
  16. Luo, Y., Li, A. and Kang, Z. (2012), "Parametric study of bonded steel-concrete composite beams by using finite element analysis", Eng. Struct., 34, 40-51. https://doi.org/10.1016/j.engstruct.2011.08.036.
  17. Mashiri, F.R., Mirza, O., Canuto, C. and Lam, D. (2017). "Post-fire Behaviour of Innovative Shear Connection for Steel-Concrete Composite Structures", Structures, https://doi.org/10.1016/j.istruc.2016.12.001.
  18. Mirza, O. (2008), "Behaviour and design of headed stud shear connectors in composite steel-concrete beams".
  19. Mostofizadeh, A., Li, Y., Song, B. and Huang, Y. (2011), "Synthesis, properties, and applications of low-dimensional carbon-related nanomaterials", J. Nanomater., 2011 16.
  20. Naser, M. and Kodur, V. (2018), "Response of fire exposed composite girders under dominant flexural and shear loading", J. Struct. Fire Eng., 9(2), 108-125.https://doi.org/10.1108/JSFE-01-2017- 0022.
  21. Nguyen, H.T. and Kim, S.E. (2009), "Finite element modeling of push-out tests for large stud shear connectors", J. Constr. Steel Res., 65(10-11), 1909-1920. https://doi.org/10.1016/j.jcsr.2009.06.010.
  22. Oehlers, D., Oehlers, D.J. and Bradford, M.A. (1999), Elementary behaviour of composite steel and concrete structural members.
  23. Pacheco-Torgal, F. and Jalali, S. (2011), "Nanotechnology: advantages and drawbacks in the field of construction and building materials", Constr. Build. Mater., 25(2), 582-590. https://doi.org/10.1016/j.conbuildmat.2010.07.009.
  24. Potapov, V., Shitikov, E., Trutnev, N., Gorbach, V. and Portnyagin, N. (2011), "Influence of silica nanoparticles on the strength characteristics of cement samples", Glass Phys. Chem., 37(1), 98-105. https://doi.org/10.1134/S1087659611010111
  25. Scrivener, K.L. and Kirkpatrick, R.J. (2008), "Innovation in use and research on cementitious material", Cement Concrete Res., 38(2), 128-136. https://doi.org/10.1016/j.cemconres.2007.09.025.
  26. Selamet, S. and Garlock, M.E. (2010), "Robust fire design of single plate shear connections", Eng. Struct., 32(8), 2367-2378.https://doi.org/10.1016/j.engstruct.2010.04.011.
  27. Shariati, M., Tahmasbi, F., Mehrabi, P., Bahadori, A., Toghroli, A.J.S. and Structures, C. (2020), "Monotonic behavior of C and L shaped angle shear connectors within steel-concrete composite beams: an experimental investigation", Steel Compos. Struct., 35(2), 237-247. https://doi.org/10.12989/scs.2020.35.2.237.
  28. Shill, S.K., Al-Deen, S. and Ashraf, M. (2018), "Concrete durability issues due to temperature effects and aviation oil spillage at military airbase-A comprehensive review", J. Constr. Build. Mater., 160, 240-251. https://doi.org/10.1016/j.conbuildmat.2017.11.025.
  29. Shill, S.K., Al-Deen, S. and Ashraf, M. (2019), "Saponification and scaling in ordinary concrete exposed to hydrocarbon fluids and high temperature at military airbases", J. Constr. Build. Mater., 215, 765-776.https://doi.org/10.1016/j.conbuildmat.2019.04.215.
  30. Shill, S.K., Al-Deen, S., Ashraf, M., Hossain, M.M.J.C. and Materials, B. (2020), "Residual properties of conventional concrete repetitively exposed to high thermal shocks and hydrocarbon fluids", 252, 119072. https://doi.org/10.1016/j.conbuildmat.2020.119072.
  31. Tao, Z., Han, L.-H., Uy, B. and Chen, X. (2011), "Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columns", J. Constr. Steel Res., 67(3), 484-496. https://doi.org/10.1016/j.jcsr.2010.09.006.
  32. Thostenson, E.T., Ren, Z. and Chou, T.W. (2001), "Advances in the science and technology of carbon nanotubes and their composites: a review", Compos. Sci. Technol., 61(13), 1899-1912. https://doi.org/10.1016/S0266-3538(01)00094-X.
  33. Tian, K., Ozbolt, J., Sharma, A. and Hofmann, J. (2018), "Experimental study on concrete edge failure of single headed stud anchors after fire exposure", Fire safety J., 96, 176-188. https://doi.org/10.1016/j.firesaf.2018.01.005.
  34. Uy, B. (2007), "Modern design, construction and maintenance of composite steel-concrete structures: Australian experiences", Proceedings of the 1st International Conference on Modern Design, Construction and Maintenance of Structures-Hanoi.
  35. Uy, B. and Liew, J. (2003), "Composite steel-concrete structures", Civil Engineering Handbook.
  36. Wang, J.Y., Guo, J.Y., Jia, L.J.., Chen, S.M. and Dong, Y. (2017), "Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures", Compos. Struct., 170, 69-79. https://doi.org/10.1016/j.compstruct.2017.03.004.
  37. Wang, W.Y.., Engelhardt, M.D., Li, G.Q. and Huang, G.S.. (2017), "Behavior of Steel-Concrete Partially Composite Beams Subjected to Fire-Part 1: Experimental Study", Fire Technol., 53(3), 1039-1058. https://doi.org/10.1007/s10694-016-0618-y