과제정보
본 논문은 산업통상자원부의 재원으로 한국에너지기술평가원의 연구(No.20206910100090)와 중소벤처기업부의 기술개발사업 지원에 [S2854105] 의해 수행되었음.
참고문헌
- Ministry of Trade, Industry and Energy, The third Energy Master Plan, 2019. https://www.etrans.or.kr/ebook/05/files/assets/common/downloads/Third Energy Master Plan.pdf
- Byeong-Gi Kim, Jae-Beom Park, Kyeong-Sang You, Dae-Seok Rho, "Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems", The Transactions of the Korean Institute of Electrical Engineers, Vol. 60, No. 8, pp. 1485~1491, 2011. DOI: https://doi.org/10.5370/KIEE.2011.60.8.1485
- Sung-Hun Park, Yong-Sik Lee, Sung-Won Jeong, Jae-Hyeon Gim, "Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System", Journal of The Korean Solar Energy Society, Vol.39, No.4, pp.69~77, 2019. DOI: https://doi.org/10.7836/kses.2019.39.4.069
- K. B. Kim, H. K. Jung, Direction of R&D investment in electric power sector based on government's energy conversion policy, KISTEP Issue Weekly, Korea, Oct 2018.
- Guideline for Interconnection of Distributed Generation System in Distribution Systems, KEPCO, 2012. DOI: http://dx.doi.org/10.5370/KIEE.2012.61.10.1536
- Kab-Seok Kang, Hu-Dong Lee, Dong-Hyun Tae.Dae-Seok Rho, "A Study on Open Phase Fault Characteristics of Interconnecting Transformer for PV System based on PSCAD/EMTDC", The Transactions P of the Korean Institute of Electrical Engineers Vol. 69P, No. 2, pp. 225~234, 2020 DOI : https://doi.org/10.5370/KIEE.2020.69.2.225
- Dong-Yeol Shin, Dong-hyun Yun, Han-Ju Cha, "Problem Analysis by Iron Core Structure of the Transformer on Asymmetric three Phase lines and Prevention Measures", The Transactions of the Korean Institute of Electrical Engineers, Vol. 61, No. 10, pp. 1536~1541, 2012. DOI : https://doi.org/10.5370/KIEE.2012.61.10.1536
- Dong-Yeol Shin, Bok-Nam Ha, Won-Wook Jung, Han-Ju Cha, "A Study on the Reverse-Power- Flow Phenomenon due to Transformer Wiring Types in Distribution System", The Korean Institute of Illuminating and electrical Installation Engineers, Vol. 22, No. 9, pp. 111~119, 2008. DOI : https://doi.org/10.5207/JIEIE.2008.22.9.111
- Dong-Hyun Tae, Hu-Dong Lee, Byeong-Gill Han, Dae-Seok Rho. "A Study on Modeling of Ferro-resonance Characteristics with Saturation of Grid-connected Transformer in Energy Storage System", The transactions of The Korean Institute of Electrical Engineers, 70(1), 51-60, 2021. DOI: http://dx.doi.org/10.5370/KIEE.2021.70.1.051
- Dong-Yeol Shin, Dong-Hyun Yun, Han-Ju Cha, "The Development of an Algorithm for the Correction of Errors in the Phase Current of the Protective Relay on Distribution System Interconnected with Distributed Generation", The Transactions of the Korean Institute of Electrical Engineers, Vol. 62, No. 11, pp. 1604~1609, 2013. DOI: http://dx.doi.org/10.5370/KIEE.2013.62.11.1604
- W. Enright, N. Watson, O.B.Nayak, "Three-phase Five-Limb Unified Magnetic Equivalent Circuit Transformer models for PSCAD V3", IPST '99 Proceedings, Budapest, pp.462-467, 1999. https://www.ipstconf.org/papers/Proc_IPST1999/99IPST028.pdf