과제정보
This research was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (Ministry of Sciences and ICT) (No. 2020M2D9A309417011).
참고문헌
- Ezzell GA, Galvin JM, Low D, Palta JR, Rosen I, Sharpe MB, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. Med Phys. 2003;30:2089-2115. https://doi.org/10.1118/1.1591194
- Chin LS, Regine WF. Principles and practice of stereotactic radiosurgery. New York: Springer Science+Business Media; 2010.
- Park HJ, Griffin RJ, Hui S, Levitt SH, Song CW. Radiation-induced vascular damage in tumors: implications of vascular damage in ablative hypofractionated radiotherapy (SBRT and SRS). Radiat Res. 2012;177:311-327. https://doi.org/10.1667/rr2773.1
- Gigliotti MJ, Hasan S, Liang Y, Chen D, Fuhrer R, Wegner RE. A 10-year experience of linear accelerator-based stereotactic radiosurgery/radiotherapy (SRS/SRT) for paraganglioma: a single institution experience and review of the literature. J Radiosurg SBRT. 2018;5:183-190.
- Kry SF, Molineu A, Kerns JR, Faught AM, Huang JY, Pulliam KB, et al. Institutional patient-specific IMRT QA does not predict unacceptable plan delivery. Int J Radiat Oncol Biol Phys. 2014;90:1195-1201. https://doi.org/10.1016/j.ijrobp.2014.08.334
- Hillman Y, Kim J, Chetty I, Wen N. Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA. Med Phys. 2018;45:1351-1359. https://doi.org/10.1002/mp.12808
- Kim JS, Park BR, Yoo J, Ha WH, Jang S, Jang WI, et al. Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity. Nucl Eng Technol. 2021. doi: 10.1016/j.net.2021.08.016.
- Molazadeh M, Robatjazi M, Geraily G, Rezaeejam H, Zeinali A, Shirazi A. Three-dimensional IMRT QA of Monte Carlo and full scatter convolution algorithms based on 3D film dosimetry. Radiat Phys Chem. 2021;186:109528. https://doi.org/10.1016/j.radphyschem.2021.109528
- Choi JW, Choi JY, Kim BC, Joo KK. Feasibility study of a portable and fast spatial dosimeter using an alcohol-based liquid scintillator and a digital camera. J Korean Phys Soc. 2021;79:810-817. https://doi.org/10.1007/s40042-021-00306-9
- Eidi T, Aghamiri SMR, Jaberi R, Baghani HR. On measuring the 3D dose distribution for notched and circular Ru106 plaque shapes through Gafchromic film dosimetry approach. Radiat Phys Chem. 2022;190:109792. https://doi.org/10.1016/j.radphyschem.2021.109792
- Silveira MA, Pavoni JF, Baffa O. Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry. Phys Med. 2017;34:1-6. https://doi.org/10.1016/j.ejmp.2016.12.007
- Lee M, Noh S, Yoon KJ, Lee SW, Yoon SM, Jung J, et al. Feasibility study of polymer gel dosimetry using a 3D printed phantom for liver cancer radiotherapy. J Korean Phys Soc. 2020;76:453-457. https://doi.org/10.3938/jkps.76.453
- Matrosic CK, Holmes S, Bednarz B, Culberson W. Evaluation of a clinical dose accumulation algorithm using deformable gel dosimetry. J Phys Conf Ser. 2019;1305:012002. https://doi.org/10.1088/1742-6596/1305/1/012002
- Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, et al. Polymer gel dosimetry. Phys Med Biol. 2010;55:R1-R63. https://doi.org/10.1088/0031-9155/55/5/R01
- Perez P, Torres PR, Bruna A, Brunetto M, Aon E, Franco D, et al. Fricke gel xylenol orange dosimeter layers for stereotactic radiosurgery: a preliminary approach. Appl Radiat Isot. 2021;178:109936. https://doi.org/10.1016/j.apradiso.2021.109936
- Hebb AO, Poliakov AV. Imaging of deep brain stimulation leads using extended Hounsfield unit CT. Stereotact Funct Neurosurg. 2009;87:155-160. https://doi.org/10.1159/000209296