DOI QR코드

DOI QR Code

Experimental Study on the Temperature Reduction Effect of the Nano-mist Facility

나노미스트형 폭염저감 시설의 온도저감 효과 - 대구광역시 서구 북비산로를 대상으로 -

  • Kim, Jaekyoung (Interdisciplinary Program in Landscape Architecture, Seoul National University) ;
  • Kang, Junsuk (Department of Landscape Architecture and Rural Systems Engineering, Seoul National University) ;
  • Kim, Hoijin (UB E&C)
  • 김재경 (서울대학교 대학원 협동과정 조경학 전공) ;
  • 강준석 (서울대학교 조경.지역시스템공학부) ;
  • 김회진 (유비 E&C)
  • Received : 2021.01.15
  • Accepted : 2021.04.01
  • Published : 2021.04.30

Abstract

This study analyzed the weather environment of the smart city to identify the temperature reduction effects of the heat reducing facilities. The methodology is divided into indoor and outdoor analyses. Indoor analyses were conducted for the evidence-based design of the facility. The size of nozzle is adjusted to derive the most efficient size for outdoor use. Three types of nozzles were used, 0.15 mm, 0.2 mm and 0.3 mm. The most efficient nozzle was selected as 0.15 mm. The outdoor test was measured for two days from August 3 to August 4, 2020, and the weather data were collected for the control and target sites on the first day. On the second day, the measurements were taken assuming that the temperature and humidity of two sites would be similar. Compared to the control group, the outdoor test site had a temperature reduction effect up to 7.4℃. When operating the heat-reducing facility, the rate of change in sensible temperature is lower than control site. This study concluded that mist facilities have a pre-cooling effect, which means reducing the temperature to a certain level. The results from this study data could be provided when establishing an adaptation policy for a heatwave.

Keywords

Acknowledgement

본 연구는 국토교통부/국토교통과학기술진흥원의 스마트시티 혁신성장동력 프로젝트 지원으로 수행되었음(과제번호 : 19NSPS-B154559-02).

References

  1. Arbel, A., Yekutieli, O., Barak, M., 1999, Performance of a fog system for cooling greenhouses, J. Agric. Eng. Res., 72(2), 129-136. https://doi.org/10.1006/jaer.1998.0351
  2. Bluestein, M., Zecher, J., 1999, A New approach to an accurate wind chill factor, Bull Am Meteorol Soc., 80(9), 1893-1900. https://doi.org/10.1175/1520-0477(1999)080<1893:ANATAA>2.0.CO;2
  3. Budd, G. M., 2008, Wet-Bulb Globe Temperature (WBGT)-its history and its limitations, J SCI MED SPORT., 11(1), 20-32. https://doi.org/10.1016/j.jsams.2007.07.003
  4. Cho, H. J., Lim, J. H., 2011, The effect of urban vegetation on a decrease of road surface temperature, Journal of the Korean Institute of Landscape Architecture, 39(3), 107-116. https://doi.org/10.9715/KILA.2011.39.3.107
  5. Daegu Metropolitan City., 2018, Daegu Metropolitan City ordinance on the response of heat and urban heat island phenomenon.
  6. IPCC, Climate Change 2014., 2014, Synthesis report. In Contribution of working groups I, II and III to the fifth assessment report of the intergovernmental panel on climate change; Core Writing Team, Pachauri, R. K., Meyer, L. A., Eds.; IPCC: Geneva, Switzerland.
  7. Jang, Y. J., Heo, H. S., Kim, B. J., Kim, S. K., Hong, G. M., Lee, W. K., 2012, The change of the average discomfort index from june to september during the past 10 years, Journal of Climate Change Research, 3(2), 89-100.
  8. Jung, H. D., 2018, A Case study on policy direction for heat response in Daejeon.
  9. Katsoulas, N., Kitta, E., Kittas, C., Tsirogiannis, I. L., Stamati, E., Sayvas, D., 2006, Greenhouse cooling by a fog system: effects on microclimate and on production and quality of a soilless pepper crop, In International Symposium on Greenhouse Cooling., 719, 455-462.
  10. Kim, J. K., Kang, J. S., Kim, H. J., 2020a, Model design and demonstration test for the verification of temperature reduction effect of cooling fog system with stainless steel, J. Environ. Sci. Int., 29(6), 683-689. https://doi.org/10.5322/JESI.2020.29.6.683
  11. Kim, J. K., Kim, W. H., Kim, E. I., 2020b, Analysis of temperature influence experiment on green spaces in campus, JKAIS., 21(2), 511-520.
  12. Kim, J. K., Lee, S. Y., Kang, J. S., 2020c, Temperature reduction effects of rooftop garden arrangements: a case study of seoul national university, Sustainability., 12(15), 6032. https://doi.org/10.3390/su12156032
  13. Korean Meteorological Administration Weather Information : http://www.kma.go.kr.
  14. Lee, C. S., Ryu, N. H., 2015, The influence of the landscaping shade membrane's brightness on the Mean Radiant Temperature (MRT) of summer outdoor, Journal of the Korean Institute of Landscape Architecture., 43(5), 65-73. https://doi.org/10.9715/KILA.2015.43.5.065
  15. Lee, S. J., Kwon, B. Y., Jung, D. H., Jo, K. H., Kim, M. S., Ha, S. M., Kim, H. N., Kim, B. N., Masud, M. A., Lee, E. I., Kim, Y. G.., 2013, Future prediction of heat and discomfort indices based on two RCP scenarios, Atmosphere, 23(2), 221-229. https://doi.org/10.14191/Atmos.2013.23.2.221
  16. National Aeronautics & Space Administration (NASA)., 2020, Goddard Institute for Space Studies (GISS), GISS surface temperature analysis.
  17. Thom, E. C., 1959, The discomfort index, Weatherwise, 12(2), 57-61. https://doi.org/10.1080/00431672.1959.9926960
  18. Wong, C. Y., Gamon, J. A., 2015, Three causes of variation in the Photochemical Reflectance Index (PRI) in evergreen conifers, New Phytologist, 206(1), 187-195. https://doi.org/10.1111/nph.13159
  19. Yoon, J. H., 2018, Revision of the framework act on the management of disasters and safety for the management of heatwaves and hampi, Monthly Public Policy., 156, 96-98.