DOI QR코드

DOI QR Code

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • You, Seung-Gyu (Health Science Research Institute, College of Health Science, Korea University) ;
  • You, Seung-Min (Health Science Research Institute, College of Health Science, Korea University) ;
  • Kim, Dong-Yeon (4RD Dental Laboratory) ;
  • Kim, Ji-Hwan (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University)
  • 투고 : 2020.12.07
  • 심사 : 2021.03.26
  • 발행 : 2021.04.30

초록

PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

키워드

참고문헌

  1. Burns DR, Beck DA, Nelson SK; Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. J Prosthet Dent 2003;90:474-97. https://doi.org/10.1016/S0022-3913(03)00259-2
  2. Cheng CW, Ye SY, Chien CH, Chen CJ, Papaspyridakos P, Ko CC. Randomized clinical trial of a conventional and a digital workflow for the fabrication of interim crowns: an evaluation of treatment efficiency, fit, and the effect of clinician experience. J Prosthet Dent 2021;125:73-81. https://doi.org/10.1016/j.prosdent.2019.08.006
  3. Ryu JE, Kim YL, Kong HJ, Chang HS, Jung JH. Marginal and internal fit of 3D printed provisional crowns according to build directions. J Adv Prosthodont 2020; 12:225-32. https://doi.org/10.4047/jap.2020.12.4.225
  4. Abdulmohsen B, Parker S, Braden M, Patel MP. A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials. Dent Mater 2016;32: 200-10. https://doi.org/10.1016/j.dental.2015.11.025
  5. Peng CC, Chung KH, Yau HT. Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods. J Prosthet Dent 2020;123:514-22. https://doi.org/10.1016/j.prosdent.2019.02.024
  6. Yu BY, Son K, Lee KB. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing. J Prosthet Dent 2020:S0022-391330385-1.
  7. Tahayeri A, Morgan M, Fugolin AP, Bompolaki D, Athirasala A, Pfeifer CS, Ferracane JL, Bertassoni LE. 3D printed versus conventionally cured provisional crown and bridge dental materials. Dent Mater 2018; 34:192-200. https://doi.org/10.1016/j.dental.2017.10.003
  8. Lee WS, Lee DH, Lee KB. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont 2017;9:265-70. https://doi.org/10.4047/jap.2017.9.4.265
  9. Revilla-Leon M, Meyers MJ, Zandinejad A, Ozcan M. A review on chemical composition, mechanical properties, and manufacturing work flow of additively manufactured current polymers for interim dental restorations. J Esthet Restor Dent 2019;31:51-7. https://doi.org/10.1111/jerd.12438
  10. You SG, You SM, Lee BI, Kim DY, Kim JH. Effect of layer thickness setting on the adaptation of stereolithography apparatus-fabricated metal frameworks for removable partial dentures: an in vitro study. J Prosthet Dent 2020;S0022-3913(20)30582-5.
  11. You SG, You SM, Kang SY, Bae SY, Kim JH. Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study. J Prosthet Dent 2021;125:479-85. https://doi.org/10.1016/j.prosdent.2020.01.039
  12. Lin WS, Harris BT, Pellerito J, Morton D. Fabrication of an interim complete removable dental prosthesis with an in-office digital light processing three-dimensional printer: a proof-of-concept technique. J Prosthet Dent 2018;120:331-4. https://doi.org/10.1016/j.prosdent.2017.12.027
  13. Hwang HJ, Lee SJ, Park EJ, Yoon HI. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing. J Prosthet Dent 2019;121:110-7. https://doi.org/10.1016/j.prosdent.2018.02.018
  14. Kim DY, Jeon JH, Kim JH, Kim HY, Kim WC. Reproducibility of different arrangement of resin copings by dental microstereolithography: evaluating the marginal discrepancy of resin copings. J Prosthet Dent 2017;117:260-5. https://doi.org/10.1016/j.prosdent.2016.07.007
  15. You SM, You SG, Kang SY, Bae SY, Kim JH. Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: an in vitro study. J Prosthet Dent 2021;125:139-45. https://doi.org/10.1016/j.prosdent.2019.12.014
  16. Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont 2016;29:503-10. https://doi.org/10.11607/ijp.4835
  17. Osman RB, Alharbi N, Wismeijer D. Build angle: Does it influence the accuracy of 3d-printed dental restorations using digital light-processing technology? Int J Prosthodont 2017;30:182-8. https://doi.org/10.11607/ijp.5117
  18. Sherman SL, Kadioglu O, Currier GF, Kierl JP, Li J. Accuracy of digital light processing printing of 3-dimensional dental models. Am J Orthod Dentofacial Orthop 2020;157:422-8. https://doi.org/10.1016/j.ajodo.2019.10.012
  19. Revilla-Leon M, Ozcan M. Additive Manufacturing Technologies Used for Processing Polymers: current Status and Potential Application in Prosthetic Dentistry. J Prosthodont 2019;28:146-58. https://doi.org/10.1111/jopr.12801
  20. Chockalingam K, Jawahar N, Chandrasekhar U. Influence of layer thickness on mechanical properties in stereolithography. Rapid Prototyp J 2006;12:106-13. https://doi.org/10.1108/13552540610652456
  21. Unkovskiy A, Bui PH, Schille C, Geis-Gerstorfer J, Huettig F, Spintzyk S. Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin. Dent Mater 2018;34:e324-33. https://doi.org/10.1016/j.dental.2018.09.011
  22. Stansbury JW, Idacavage MJ. 3D printing with polymers: challenges among expanding options and opportunities. Dent Mater 2016;32:54-64. https://doi.org/10.1016/j.dental.2015.09.018
  23. Kang SY, Park JH, Kim JH, Kim WC. Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique. J Adv Prosthodont 2018;10:354-60. https://doi.org/10.4047/jap.2018.10.5.354
  24. Jockusch J, Ozcan M. Additive manufacturing of dental polymers: an overview on processes, materials and applications. Dent Mater J 2020;39:345-54. https://doi.org/10.4012/dmj.2019-123
  25. ISO-12836. Digitizing devices for CAD/CAM systems for indirect dental restorations - test methods for assessing accuracy. Geneva, Switzerland: International Standards for Organization (ISO); 2012 Available at: https://www.iso.org/iso/store.html.
  26. Kang SY, Park JH, Kim JH, Kim WC. Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: an in vitro study. J Prosthodont Res 2020;64:152-8. https://doi.org/10.1016/j.jpor.2019.06.004
  27. Wang W, Yu H, Liu Y, Jiang X, Gao B. Trueness analysis of zirconia crowns fabricated with 3-dimensional printing. J Prosthet Dent 2019;121:285-91. https://doi.org/10.1016/j.prosdent.2018.04.012
  28. Michelinakis G, Apostolakis D, Tsagarakis A, Kourakis G, Pavlakis E. A comparison of accuracy of 3 intraoral scanners: a single-blinded in vitro study. J Prosthet Dent 2020;124:581-8. https://doi.org/10.1016/j.prosdent.2019.10.023
  29. Katheng A, Kanazawa M, Iwaki M, Minakuchi S. Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions: an in vitro study. J Prosthet Dent 2021;125:695-702. https://doi.org/10.1016/j.prosdent.2020.02.023
  30. Kalberer N, Mehl A, Schimmel M, Muller F, Srinivasan M. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness. J Prosthet Dent 2019;121:637-43. https://doi.org/10.1016/j.prosdent.2018.09.001
  31. Park GS, Kim SK, Heo SJ, Koak JY, Seo DG. Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics. Materials (Basel) 2019;12:2533. https://doi.org/10.3390/ma12162533
  32. Bass L, Meisel NA, Williams CB. Exploring variability of orientation and aging effects in material properties of multi-material jetting parts. Rapid Prototyp J 2016;22:826-34. https://doi.org/10.1108/RPJ-11-2015-0169
  33. Khoshkhoo A, Carrano AL, Blersch DM. Effect of build orientation and part thickness on dimensional distortion in material jetting processes. Rapid Prototyp J 2018;24:1563-71. https://doi.org/10.1108/RPJ-10-2017-0210
  34. Patzelt SB, Bishti S, Stampf S, Att W. Accuracy of computer-aided design/computer-aided manufacturing-generated dental casts based on intraoral scanner data. J Am Dent Assoc 2014;145:1133-40. https://doi.org/10.14219/jada.2014.87
  35. Ishida Y, Miyasaka T. Dimensional accuracy of dental casting patterns created by 3D printers. Dent Mater J 2016;35:250-6. https://doi.org/10.4012/dmj.2015-278
  36. Kirsch C, Ender A, Attin T, Mehl A. Trueness of four different milling procedures used in dental CAD/CAM systems. Clin Oral Investig 2017;21:551-8. https://doi.org/10.1007/s00784-016-1916-y
  37. Berger U. Aspects of accuracy and precision in the additive manufacturing of plastic gears. Virtual Phys Prototyp 2015;10:49-57. https://doi.org/10.1080/17452759.2015.1026127
  38. Wu D, Zhao Z, Zhang Q, Qi HJ, Fang D. Mechanics of shape distortion of DLP 3D printed structures during UV post-curing. Soft Matter 2019;15:6151-9. https://doi.org/10.1039/C9SM00725C
  39. Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent 2016;115:313-20. https://doi.org/10.1016/j.prosdent.2015.09.011
  40. Chen H, Cheng DH, Huang SC, Lin YM. Comparison of flexural properties and cytotoxicity of interim materials printed from mono-LCD and DLP 3D printers. J Prosthet Dent 2020;S0022-3913(20)30467-4.