DOI QR코드

DOI QR Code

국내 디클로로메탄 제조·사용 사업장 근로자의 공정별 노출수준에 대한 작업환경측정값과 ECETOC TRA 모델값 비교연구

Comparative Study of Korean Workers' Exposure to Dichloromethane by Process Category between Work Environment Monitoring Program and ECETOC TRA

  • 정수진 (한국산업안전보건공단 산업안전보건연구원) ;
  • 배계완 (한국산업안전보건공단) ;
  • 이나루 (한국산업안전보건공단 산업안전보건연구원)
  • Jeong, Sujin (Occupational Safety and Health Research Institute (OSHRI), Korea Occupational Safety and Health Agency (KOSHA)) ;
  • Bae, Gyewan (Korea Occupational Safety and Health Agency (KOSHA)) ;
  • Lee, Naroo (Occupational Safety and Health Research Institute (OSHRI), Korea Occupational Safety and Health Agency (KOSHA))
  • 투고 : 2021.06.09
  • 심사 : 2021.12.15
  • 발행 : 2021.12.30

초록

Objectives: By law, companies in Korea must periodically measure workers' exposure to harmful chemicals (the system is called the Work Environment Monitoring Program (WMP)[a]) and report the results to the government. The government also measures exposure to monitor the WMP's reliability (called Reliability Assessment (RA) for WMP[b]). The issue is that measured data from these two sources are so different that the objectivity of WMP needs to be confirmed by comparing the results using the European Centre for Ecotoxicology and Toxicology of Chemicals' Targeted Risk Assessment (ECETOC TRA). Methods: Step 1: Data collection from WMP reports submitted by companies (n=586) and RA for WMP written by the government (n=33). Step 2: Data Standardization by key information included. Step 3: Data conversion to input-variables required to run the ECETOC TRA model, and run the model with specific data (n=514) which meet the predetermined exposure scenario. Step 4: Statistical data analysis by process category (PROC) and ventilation type from each source ([A] and [B]). Step 5: Additional analysis of any unexpected results. Results: The process categories of the production and handling of Dichloromethane were classified into 12 PROCs, and ten of them were selected to run ECETOC TRA. Modeled values tended to be higher than measured values from both sources. For the measured values from WMP, RCR distribution by PROC was narrow (0.197-0.267, 95% CI) and did not have a relationship with ventilation type, which differs from the tendency of the modeling result. Meanwhile, the measured values from RA for WMP were relatively widely distributed (0.301-1.177, 95% CI) by PROC. In particular PROCs (13,19) were high enough to exceed 1. Also, they become low with better ventilation types and appear differently depending on the ventilation type, similar to the model result. Conclusions: This study revealed that ECETOC TRA might have the potential to serve as a screening tool for exposure assessment and to be used as assistive method for WMP to estimate exposure. Further empirical study is required to confirm its availability as a screening tool.

키워드

참고문헌

  1. European Centre for Ecotoxicology and Toxicology of Chemical (ECETOC). Targeted Risk Assessment (TRA) (Technical Report No. 93).; 2004. p. 22
  2. European Centre for Ecotoxicology and Toxicology of Chemical (ECETOC). Version 3 Technical Report (TR): Background and Rationale for the Improvements (Public Notice: ECETOC TR114).; 2012. p. 8-11, 59-62
  3. European Centre for Ecotoxicology and Toxicology of Chemical (ECETOC). Targeted Risk Assessment (TRA) Technical Report (TR): Further Explanation of the Technical Basis of the TRA v3.1 (Public Notice: ECETOC TR131).; 2018. p. 4-5
  4. European Centre for Ecotoxicology and Toxicology of Chemical (ECETOC). Targeted Risk Assessment (TRA) User Guide for the integrated tool TRAM Version 3 update to version 3.1.; June 2017. p. 8-9
  5. European Chemicals Agency (ECHA). Guidance for Human Health Risk Assessment. Volume III Human Health, Part B Risk Assessment Draft Version 2.0 (May 2015).; 2015. p. 31
  6. European Chemicals Agency (ECHA). Guidance on Information Requirements and Chemical Safety Assessment, Chapter R.12: Use description, Version 3.0 (December 2015).; 2015. p. 49-54
  7. European Chemicals Agency (ECHA). Guidance on Information Requirements and Chemical Safety Assessment. Chapter R.14: Occupational exposure assessment, Version 3.0 (August 2016).; 2016. p. 37, 38, 54
  8. European Chemicals Agency (ECHA). Guidance on the Biocidal Products Regulation, Volume III Human Health - Assessment & Evaluation (Parts B+C), Version 4.0 (December 2017).; 2017. p. 194
  9. Kang SK. Chemical poisoning, how to prevent it? - inform PROPER chemical information to workers, Comment on Safety and Health, Korea Enterprises Federation (KEF) No. 2007-5.; 2007. Available from: URL: http://www.kefplaza.com/labor/labor_print.jsp?nodeId=181&idx=4484
  10. Kim KE, Kim JW, Jeon HP, Kim SH, Cheong YS. Enhancement of Occupational Exposure Assessment in Korea through the Evaluation of ECETOC TRA according to PROCs. J Environ Health Sci. 2019; 45(2): 173-185
  11. Kim W, Kim SB, Cho JH, Choi IJ, Lee YG. The study on the regulation for restriction on hazardous substances in industrial products to manage unacceptable risk. Occupational Safety and Health Research Institute, KOSHA (Korea Occupational Safety and Health Agency). 2019.
  12. Lee NR, Cho JH, Yu BW, Lee IS. Research on Regulatory Policy in Governments and Management Scheme in Company of Chemicals to protect Workers from Hazardous Chemicals. Occupational Safety and Health Research Institute, KOSHA (Korea Occupational Safety and Health Agency). 2019.
  13. Ministry of Employment and Labor (MoEL). Public Notice concerning Exposure Limits for Chemicals and Physical Agents (MoEL Public Notice No. 2018-62).; 2018.
  14. Moon JS, Ock JW, Jung UH, Ra JS, Kim KT. Occupational Exposure Assessment for Benzene Using Exposure Models (ECETOC TRA and Stoffenmanager) and Applicability Evaluation of Exposure Models in K-REACH, J Environ Health Sci. 2018; 44(5): 460-467
  15. Schlueter U, Tischer M. Validity of Tier 1 Modelling Tools and Impacts on Exposure Assessments within REACH Registrations-ETEAM Project, Validation Studies and Consequences. Int. J. Environ. Res. Public Health 2020; 17(12), 4589 https://doi.org/10.3390/ijerph17124589