Abstract
Recently, various piloti structures have been constructed in Korea to secure residential and parking spaces. However, these piloti structures have been constructed in the form of protruding columns without walls to secure parking spaces on the first floor. In this form, when an earthquake occurs, the column is relatively easily damaged compared to general structures, and such damage can lead to the collapse of the structure. Therefore, in this study, a study on securing the safety of the piloti structure using the MPS (Multi Performance System) seismic isolation device was conducted. Nonlinear dynamic analysis according to the presence or absence of MPS seismic isolation device was performed on the existing piloti structure, and analysis results were compared and analyzed. Finally, each seismic performance evaluation was performed and the superiority of the MPS seismic isolation device was verified.
최근 우리나라는 주거 및 주차 공간의 확보를 위해 다양한 필로티 구조물이 건설되어 왔다. 하지만 이러한 필로티 구조물은 1층에 주차 공간을 확보하기 위해 벽체가 없는 돌출된 기둥의 형태로 건설되어 왔다. 이러한 형태는 지진 발생 시 일반적인 구조물에 비해 상대적으로 기둥의 파손이 쉽게 발생하며, 이러한 파손은 구조물의 붕괴로 이어질 수 있다. 따라서 본 연구에서는 MPS (Multi Performance System) 면진받침을 활용한 필로티 구조물의 안전성 확보에 대한 연구를 수행하였다. 기존에 건설되어 있는 필로티 구조물에 대해 MPS 면진받침 설치 유무에 따른 비선형 동적 해석을 수행하고 해석결과를 비교 및 분석하였다. 최종적으로 각각의 내진성능 평가를 수행하고 MPS 면진받침의 성능을 검증하였다.