DOI QR코드

DOI QR Code

First Results of the Single Heartstring Aortotomy for Multiple Off-Pump Vein Grafts: A Case Series

  • Received : 2020.03.27
  • Accepted : 2020.05.07
  • Published : 2020.12.05

Abstract

To validate the technique of the single Heartstring aortotomy for multiple off-pump venous bypass grafts (described in 2015), the results of a 38-month follow-up study of 18 patients, including high-risk patients, are presented. No early deaths or cardiac or cerebral complications occurred. During the follow-up period, 2 patients died of non-cardiac causes, and 3 developed coronary ischemia. Ischemia occurred due to late graft occlusion in 2 patients, both of whom had normal postoperative courses and correct graft flow. The presence of acute symptoms 24 months after surgery in these patients indicated that technical graft failure was unlikely. This safe technique combines the advantages of simple and reproducible revascularization, the off-pump approach, and minimal aortic manipulation.

Keywords

References

  1. Niclauss L, Colombier S, Pretre R. Single Heartstring aortotomy for multiple off-pump venous bypass grafts. Asian Cardiovasc Thorac Ann 2015;23:609-11. https://doi.org/10.1177/0218492314539952
  2. Sousa-Uva M, Neumann FJ, Ahlsson A, et al. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur J Cardiothorac Surg 2019;55:4-90. https://doi.org/10.1093/ejcts/ezy289
  3. Borgermann J, Hakim K, Renner A, et al. Clampless off-pump versus conventional coronary artery revascularization: a propensity score analysis of 788 patients. Circulation 2012;126(11 Suppl 1):S176-82. https://doi.org/10.1161/CIRCULATIONAHA.111.084285
  4. Guerrieri Wolf L, Abu-Omar Y, Choudhary BP, Pigott D, Taggart DP. Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: the effect of an aortic side-biting clamp and two clampless devices. J Thorac Cardiovasc Surg 2007;133:485-93. https://doi.org/10.1016/j.jtcvs.2006.10.002
  5. Goldman S, Sethi GK, Holman W, et al. Radial artery grafts vs saphenous vein grafts in coronary artery bypass surgery: a randomized trial. JAMA 2011;305:167-74. https://doi.org/10.1001/jama.2010.1976
  6. McKavanagh P, Yanagawa B, Zawadowski G, Cheema A. Management and prevention of saphenous vein graft failure: a review. Cardiol Ther 2017;6:203-23. https://doi.org/10.1007/s40119-017-0094-6
  7. Lamy A, Devereaux PJ, Prabhakaran D, et al. Off-pump or on-pump coronary-artery bypass grafting at 30 days. N Engl J Med 2012;366:1489-97. https://doi.org/10.1056/NEJMoa1200388
  8. Dybdahl B, Wahba A, Haaverstad R, et al. On-pump versus off-pump coronary artery bypass grafting: more heat-shock protein 70 is released after on-pump surgery. Eur J Cardiothorac Surg 2004;25:985-92. https://doi.org/10.1016/j.ejcts.2004.03.002