PURPOSE. The bond strengths between resin denture teeth with various compositions and denture base resins including conventional and CAD/CAM purposed materials were evaluated to find influence of each material. MATERIALS AND METHODS. Cylindrical rods (6.0 mm diameter × 8.0 mm length) prepared from pre-polymerized CAD/CAM denture base resin blocks (PMMA Block-pink; Huge Dental Material, Vipi Block-Pink; Vipi Industria) were bonded to the basal surface of resin teeth from three different companies (VITA MFT®; VITA Zahnfabrik, Endura Posterio®; SHOFU Dental, Duracross Physio®; Nissin Dental Products Inc.) using resin cement (Super-Bond C&B; SUN MEDICAL). As a control group, rods from a conventional heat-polymerizing denture base resin (Vertex™ Rapid Simplified; Vertex-Dental B.V. Co.) were attached to the resin teeth using the conventional flasking and curing method. Furthermore, the effect of air abrasion was studied with the highly cross-linked resin teeth (VITA MFT®) groups. The shear bond strengths were measured, and then the fractured surfaces were examined to analyze the mode of failure. RESULTS. The shear bond strengths of the conventional heat-polymerizing PMMA denture resin group and the CAD/CAM denture base resin groups were similar. Air abrasion to VITA MFT® did not improve shear bond strengths. Interfacial failure was the dominant cause of failure for all specimens. CONCLUSION. Shear bond strengths of CAD/CAM denture base materials and resin denture teeth using resin cement are comparable to those of conventional methods.

키워드

참고문헌

  1. MacEntee MI, Walton JN. The economics of complete dentures and implant-related services: a framework for analysis and preliminary outcomes. J Prosthet Dent 1998;79:24-30. https://doi.org/10.1016/S0022-3913(98)70189-1
  2. Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention-a review. Part 1. Aust Dent J 1993;38:216-9. https://doi.org/10.1111/j.1834-7819.1993.tb03067.x
  3. Zarb GA, Bolender CL, Eckert SE, Jacob RF, Mericske-Stern R. Prosthodontic treatment for edentulous patients. Mosby. 12th ed. 2005. p. 195-7.
  4. Jacob RF. The traditional therapeutic paradigm: complete denture therapy. J Prosthet Dent 1998;79:6-13. https://doi.org/10.1016/S0022-3913(98)70186-6
  5. Lung CY, Darvell BW. Minimization of the inevitable residual monomer in denture base acrylic. Dent Mater 2005;21:1119-28. https://doi.org/10.1016/j.dental.2005.03.003
  6. Pereira-Cenci T, Del Bel Cury AA, Crielaard W, Ten Cate JM. Development of Candida-associated denture stomatitis: new insights. J Appl Oral Sci 2008;16:86-94. https://doi.org/10.1590/S1678-77572008000200002
  7. Steinmassl PA, Klaunzer F, Steinmassl O, Dumfahrt H, Grunert I. Evaluation of currently available CAD/CAM denture systems. Int J Prosthodont 2017;30:116-22. https://doi.org/10.11607/ijp.5031
  8. Kippax A, Watson CJ, Basker RM, Pentland JE. How well are complete dentures copied? Br Dent J 1998;185:129-33. https://doi.org/10.1038/sj.bdj.4809748
  9. Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
  10. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16.
  11. Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent 2015;114:818-25. https://doi.org/10.1016/j.prosdent.2015.08.001
  12. Bidra AS, Farrell K, Burnham D, Dhingra A, Taylor TD, Kuo CL. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes. J Prosthet Dent 2016;115:578-86. https://doi.org/10.1016/j.prosdent.2015.10.023
  13. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994;7:17-21.
  14. Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil 1997;24:540-8. https://doi.org/10.1046/j.1365-2842.1997.00522.x
  15. Kattadiyil MT, AlHelal A, Goodacre BJ. Clinical complications and quality assessments with computer-engineered complete dentures: A systematic review. J Prosthet Dent 2017;117:721-8. https://doi.org/10.1016/j.prosdent.2016.12.006
  16. Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig 2017;21:1697-705. https://doi.org/10.1007/s00784-016-1961-6
  17. Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-6. https://doi.org/10.4012/dmj.2010-112
  18. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56. https://doi.org/10.1016/j.prosdent.2016.02.017
  19. Han W, Li Y, Zhang Y, Lv Y, Zhang Y, Hu P, Liu H, Ma Z, Shen Y. Design and fabrication of complete dentures using CAD/CAM technology. Medicine (Baltimore) 2017;96:e5435. https://doi.org/10.1097/MD.0000000000005435
  20. Ohkubo C, Shimpo H, Tokue A, Park EJ, Kim TH. Complete denture fabrication using piezography and CAD-CAM: A clinical report. J Prosthet Dent 2018;119:334-8. https://doi.org/10.1016/j.prosdent.2017.04.013
  21. AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: A clinical study. J Prosthet Dent 2017;117:233-8. https://doi.org/10.1016/j.prosdent.2016.08.007
  22. Chai J, Takahashi Y, Takahashi T, Habu T. Bonding durability of conventional resinous denture teeth and highly crosslinked denture teeth to a pour-type denture base resin. Int J Prosthodont 2000;13:112-6.
  23. Zeng J, Sato Y, Ohkubo C, Hosoi T. In vitro wear resistance of three types of composite resin denture teeth. J Prosthet Dent 2005;94:453-7. https://doi.org/10.1016/j.prosdent.2005.08.010
  24. Choi YS, Lee JS, Cho IH. Comparative study on wear resistance and hardness of several artificial resin tooth. J Korean Acad Stomatognathic Funct Occlusion 2008;24:2:129-46.
  25. Suzuki S, Sakoh M, Shiba A. Adhesive bonding of denture base resins to plastic denture teeth. J Biomed Mater Res 1990;24:1091-103. https://doi.org/10.1002/jbm.820240811
  26. Kawara M, Carter JM, Ogle RE, Johnson RR. Bonding of plastic teeth to denture base resins. J Prosthet Dent 1991;66:566-71. https://doi.org/10.1016/0022-3913(91)90525-2
  27. Loyaga-Rendon PG, Takahashi H, Hayakawa I, Iwasaki N. Compositional characteristics and hardness of acrylic and composite resin artificial teeth. J Prosthet Dent 2007;98:141-9. https://doi.org/10.1016/S0022-3913(07)60047-X
  28. Lee YI , Cho IH , Lee JS. The effect of various foods on the color stability of artificial teeth. J Korean Acad Prosthodont 2009;47:82-90. https://doi.org/10.4047/jkap.2009.47.1.82
  29. https://www.vita-zahnfabrik.com/en/Technician-Solutions/Removable-prosthetics/Standard-prosthetics/VITA-MFTPosterior-51995,27568.html
  30. http://www.shofu.com.sg/downloads/pdf/Endura%20Brochure-ref.pdf
  31. Thean HP, Chew CL, Goh KI. Shear bond strength of denture teeth to base: a comparative study. Quintessence Int 1996;27:425-8.
  32. Patil SB, Naveen BH, Patil NP. Bonding acrylic teeth to acrylic resin denture bases: a review. Gerodontology 2006;23:131-9. https://doi.org/10.1111/j.1741-2358.2006.00129.x
  33. Pero AC, Scavassin PM, Perin Leite AR, Mendoza Marin DO, Paleari AG, Compagnoni MA. Effect of immersion cleansers on the bond strength between a denture base resin and acrylic resin teeth. Int J Adhesion Adhesives 2013; 44:180-3. https://doi.org/10.1016/j.ijadhadh.2013.02.011
  34. Vallittu PK1, Ruyter IE, Nat R. The swelling phenomenon of acrylic resin polymer teeth at the interface with denture base polymers. J Prosthet Dent 1997;78:194-9. https://doi.org/10.1016/S0022-3913(97)70125-2
  35. Civjan S, Huget EF, de Simon LB. Modifications of the fluid resin technique. J Am Dent Assoc 1972;85:109-12. https://doi.org/10.14219/jada.archive.1972.0269
  36. Takahashi Y, Chai J, Takahashi T, Habu T. Bond strength of denture teeth to denture base resins. Int J Prosthodont 2000;13:59-65.
  37. Kim IJ, Lee JH, Cho IH. A study on the shear bond strength of resin artificial tooth depending on repair techniques. J Dent Rehabil Appl Sci 2005;21:143-51.
  38. Saavedra G, Valandro LF, Leite FP, Amaral R, Ozcan M, Bottino MA, Kimpara ET. Bond strength of acrylic teeth to denture base resin after various surface conditioning methods before and after thermocycling. Int J Prosthodont 2007;20:199-201.
  39. Korkmaz T, Dogan A, Dogan OM, Demir H. The bond strength of a highly cross-linked denture tooth to denture base polymers: a comparative study. J Adhes Dent 2011;13:85-92. https://doi.org/10.3290/j.jad.a18241
  40. Bahrani F, Khaledi AA. Effect of surface treatments on shear bond strength of denture teeth to denture base resins. Dent Res J (Isfahan) 2014;11:114-8.
  41. Darbar UR, Huggett R, Harrison A. Denture fracture-a survey. Br Dent J 1994;176:342-5. https://doi.org/10.1038/sj.bdj.4808449
  42. Bilhan H, Erdogan O, Ergin S, Celik M, Ates G, Geckili O. Complication rates and patient satisfaction with removable dentures. J Adv Prosthodont 2012;4:109-15. https://doi.org/10.4047/jap.2012.4.2.109

피인용 문헌

  1. Comparison of shear bond strengths of different types of denture teeth to different denture base resins vol.12, pp.6, 2020, https://doi.org/10.4047/jap.2020.12.6.376
  2. Influence of Dental Glass Fibers and Orthopedic Mesh on the Failure Loads of Polymethyl Methacrylate Denture Base Resin vol.13, pp.16, 2021, https://doi.org/10.3390/polym13162793