DOI QR코드

DOI QR Code

Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems

  • Tufenkci, Pelin (Department of Endodontics, Faculty of Dentistry, Hatay Mustafa Kemal University) ;
  • Orhan, Kaan (Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University) ;
  • Celikten, Berkan (Department of Endodontics, Faculty of Dentistry, Ankara University) ;
  • Bilecenoglu, Burak (Department of Anatomy, Faculty of Dentistry, Ankara University) ;
  • Gur, Gurkan (Department of Conservative Dentistry, Faculty of Dentistry, Ankara University) ;
  • Sevimay, Semra (Department of Endodontics, Faculty of Dentistry, Ankara University)
  • 투고 : 2019.05.21
  • 심사 : 2020.03.04
  • 발행 : 2020.08.31

초록

Objectives: This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods: In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results: No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions: These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.

키워드

참고문헌

  1. Peters OA, Schonenberger K, Laib A. Effects of four Ni-Ti preparation techniques on root canal geometry assessed by micro computed tomography. Int Endod J 2001;34:221-230. https://doi.org/10.1046/j.1365-2591.2001.00373.x
  2. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269-296.
  3. Mittal A, Dadu S, Singh NS, Singh S, Gupta B, Abraham A, Yendrembam B, Kumari S. Comparative assessment of canal transportation and centering ability of Reciproc and One Shape File systems using CBCT-an in vitro study. J Clin Diagn Res 2017;11:ZC31-ZC34.
  4. Schafer E, Tepel J, Hoppe W. Properties of endodontic hand instruments used in rotary motion. Part 2. Instrumentation of curved canals. J Endod 1995;21:493-497. https://doi.org/10.1016/S0099-2399(06)80519-4
  5. Celikten B, Uzuntas CF, Kursun S, Orhan AI, Tufenkci P, Orhan K, Demiralp KO. Comparative evaluation of shaping ability of two nickel-titanium rotary systems using cone beam computed tomography. BMC Oral Health 2015;15:32. https://doi.org/10.1186/s12903-015-0019-5
  6. Thompson SA, Dummer PM. Shaping ability of lightspeed rotary nickel-titanium instruments in simulated root canals. Part 1. J Endod 1997;23:698-702. https://doi.org/10.1016/S0099-2399(97)80405-0
  7. Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry. Am J Dent 2001;14:324-333.
  8. Duque JA, Vivan RR, Cavenago BC, Amoroso-Silva PA, Bernardes RA, Vasconcelos BC, Duarte MA. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems. J Appl Oral Sci 2017;25:27-33. https://doi.org/10.1590/1678-77572016-0230
  9. Alapati SB, Brantley WA, Iijima M, Clark WA, Kovarik L, Buie C, Liu J, Ben Johnson W. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments. J Endod 2009;35:1589-1593. https://doi.org/10.1016/j.joen.2009.08.004
  10. Zhou H, Peng B, Zheng YF. An overview of the mechanical properties of nickel titanium endodontic instruments. Endod Topics 2013;29:42-54. https://doi.org/10.1111/etp.12045
  11. Micro Mega. One Curve, the Endo DNA [Internet]. Besancon: Micro Mega; c2018 [cited 2018 Jul 30]. Available from: https://micro-mega.com/shaping/one-curve?lang=en.(updated 2018 Jul 30).
  12. Peters OA, Arias A, Paque F. A micro-computed tomographic assessment of root canal preparation with a novel instrument, TRUShape, in mesial roots of mandibular molars. J Endod 2015;41:1545-1550. https://doi.org/10.1016/j.joen.2015.06.007
  13. Micro Mega. MM.Tooth, as Real as a Natural Tooth, the Ideal Training Material [Internet]. Besancon: Micro Mega; c2018 [cited 2018 Jul 30]. Available from: https://micro-mega.com/mm-tooth?lang=en.(updated 2018 Jul 30).
  14. Feldkamp LA, Goldstein SA, Parfitt AM, Jesion G, Kleerekoper M. The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 1989;4:3-11. https://doi.org/10.1002/jbmr.5650040103
  15. Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996;22:369-375. https://doi.org/10.1016/S0099-2399(96)80221-4
  16. Keskin C, Demiral M, Sariyilmaz E. Comparison of the shaping ability of novel thermally treated reciprocating instruments. Restor Dent Endod 2018;43:e15. https://doi.org/10.5395/rde.2018.43.e15
  17. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Progressive versus constant tapered shaft design using NiTi rotary instruments. Int Endod J 2003;36:288-295. https://doi.org/10.1046/j.1365-2591.2003.00650.x
  18. Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography. Int Endod J 2001;34:390-398. https://doi.org/10.1046/j.1365-2591.2001.00413.x
  19. Peters OA, Laib A, Gohring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod 2001;27:1-6. https://doi.org/10.1097/00004770-200101000-00001
  20. Versiani MA, Pecora JD, Sousa-Neto MD. The anatomy of two-rooted mandibular canines determined using micro-computed tomography. Int Endod J 2011;44:682-687. https://doi.org/10.1111/j.1365-2591.2011.01879.x
  21. Versiani MA, Leoni GB, Steier L, De-Deus G, Tassani S, Pecora JD, de Sousa-Neto MD. Micro-computed tomography study of oval-shaped canals prepared with the self-adjusting file, Reciproc, WaveOne, and ProTaper Universal systems. J Endod 2013;39:1060-1066. https://doi.org/10.1016/j.joen.2013.04.009
  22. Zhao D, Shen Y, Peng B, Haapasalo M. Root canal preparation of mandibular molars with 3 nickel-titanium rotary instruments: a micro-computed tomographic study. J Endod 2014;40:1860-1864. https://doi.org/10.1016/j.joen.2014.06.023
  23. Stern S, Patel S, Foschi F, Sherriff M, Mannocci F. Changes in centring and shaping ability using three nickel-titanium instrumentation techniques analysed by micro-computed tomography (${\mu}CT$). Int Endod J 2012;45:514-523. https://doi.org/10.1111/j.1365-2591.2011.02004.x
  24. Ertugrul IF. Effect of sodium hypochlorite on the cyclic fatigue resistance: a scanning electron microscopy evaluation. Microsc Res Tech 2019;82:2089-2094. https://doi.org/10.1002/jemt.23381
  25. Arias A, Singh R, Peters OA. Torque and force induced by ProTaper Universal and ProTaper Next during shaping of large and small root canals in extracted teeth. J Endod 2014;40:973-976. https://doi.org/10.1016/j.joen.2013.11.019
  26. Ruddle CJ, Machtou P, West JD. The shaping movement: fifth-generation technology. Dent Today 2013;32:94, 96-99.
  27. Capar ID, Ertas H, Ok E, Arslan H, Ertas ET. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod 2014;40:852-856. https://doi.org/10.1016/j.joen.2013.10.010
  28. Burklein S, Poschmann T, Schafer E. Shaping ability of different nickel-titanium systems in simulated S-shaped canals with and without glide path. J Endod 2014;40:1231-1234. https://doi.org/10.1016/j.joen.2014.01.043
  29. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod 2000;26:210-216. https://doi.org/10.1097/00004770-200004000-00003
  30. Uzunoglu E, Turker SA. Comparison of canal transportation, centering ratio by cone-beam computed tomography after preparation with different file systems. J Contemp Dent Pract 2015;16:360-365. https://doi.org/10.5005/jp-journals-10024-1690
  31. Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod 2015;41:1134-1138. https://doi.org/10.1016/j.joen.2015.02.030
  32. Hulsmann M, Peters OA, Dummer PMH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 2005;10:30-76. https://doi.org/10.1111/j.1601-1546.2005.00152.x
  33. Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod 2012;38:1618-1621. https://doi.org/10.1016/j.joen.2012.09.011
  34. Elnaghy AM. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files. Int Endod J 2014;47:1034-1039. https://doi.org/10.1111/iej.12244
  35. Ninan E, Berzins DW. Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments. J Endod 2013;39:101-104. https://doi.org/10.1016/j.joen.2012.08.010
  36. Testarelli L, Plotino G, Al-Sudani D, Vincenzi V, Giansiracusa A, Grande NM, Gambarini G. Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel. J Endod 2011;37:1293-1295. https://doi.org/10.1016/j.joen.2011.05.023
  37. Uygun AD, Kol E, Topcu MK, Seckin F, Ersoy I, Tanriver M. Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at different levels. Int Endod J 2016;49:494-499. https://doi.org/10.1111/iej.12471

피인용 문헌

  1. Micro-computed tomography in preventive and restorative dental research: A review vol.51, 2020, https://doi.org/10.5624/isd.20210087