DOI QR코드

DOI QR Code

Physicochemical Analysis according to Temperature Changes of Iopamidol and Ioversol Formulation Contrast Agents

Iopamidol과 Ioversol 제제 조영제의 온도변화에 따른 물리화학적 분석

  • Han, Beom-Hee (R&D Team of Radiation Science Technology Laboratory)
  • 한범희 (방사선과학기술연구소 연구개발팀)
  • Received : 2020.08.10
  • Accepted : 2020.08.29
  • Published : 2020.08.31

Abstract

In this study, the P contrast agent of Iopamidol, which is a nonionic iodide contrast agent most commonly used as a vascular contrast agent in medical institutions, and the O contrast agent of Ioversol, were studied. The physicochemical changes according to the temperature change were compared and analyzed using the Bruker Avance 500MHz Nuclear Magnetic Resonance Spectrometer owned by the Korea Basic Science Institute (KBSI). There was no physical or chemical change in the O contrast medium of Ioversol formulation in temperature change. However, in the P contrast agent of Iopamidol, a doublet peak began to appear in the 1.1 ppm region of the sample at 60℃, and the doublet peak was clearly observed in the sample at 80℃. As a result of this study, 1H-NMR analysis revealed that the P contrast agent of the Iopamidol formulation was dissociated from chemical bonds as it rose to a high temperature of 60℃ or higher, resulting in the formation of foreign substances. It was evaluated that the O contrast agent of Ioversol formulation had physico-chemical stability than the P contrast agent of Iopamidol formulation. As shown in this study, it is necessary to analyze the physical and chemical changes of contrast agents according to various environmental factors.

Keywords

References

  1. ESUR Contrast Media Safety Committee. ESUR guidelines on contrast media. European Society of Urogenital Radiology; 2007.
  2. Ko IH, Kim KK, Kim DY, Kim MK, Kim MC, Kim JS, et al. Textbook computed tomography. Chung-Ku Publisher; 2005.
  3. Park CM, Lee MK, Song TB, Lee BR, Lim SC, Jang JK, et al. Safety evaluation of iopamidol contrast medium used for radiological examination of a local clinic in Korea. Yakhak Hoeji. 2009;53(6): 328-33.
  4. Yang WS, Shin SG. Consideration of adverse reaction to MDCT contrast media. Journal of Radiological Science and Technology. 2012;35(1):51-7.
  5. Jang KJ, Kweon DC, Kim MG, Yoo BG. Development and Implementation of a Critical Pathway for Prevention of Adverse Reactions to Contrast Media for Computed Tomography. Journal of Radiological Science and Technology. 2007;30(1):39-46.
  6. Kang YH. The Precaution duty and the product liability for adverse reactions to the contrast media. Journal of Radiological Science and Technology. 2007:30(4):305-11.
  7. Kwon KS. Analysis of adverse reactions to CT contrast medium. University of Ulsan; 2004.
  8. Wieten DM, Hirsch FD, Hartman GW. Acute reaction to urographic contrast medium: Incidence, clinical characteristics and relationships to hypersensitivity states. Am J Roentgenol. 1973;119:832-40. https://doi.org/10.2214/ajr.119.4.832
  9. Siegle R, Halvosen R, Dillon J, et al. The use of iohexol in patients with previous reactions to ionic contrast material. Invest Radiol. 1991;26:411-6. https://doi.org/10.1097/00004424-199105000-00004
  10. Dawson P, David O, Ronald G. Textbook contrast media. British Library; 1999.
  11. Lee SK. The analysis of NMR spectrum. Hanrimwon; 2014.
  12. Hyun-Sook Hong, Dae-Ho Kim, Hae-Kyung Lee, Moo-Chan Chung, Deuk-Lin Choi, Kuy-Hyang Kwon, Ki-Jung Kim. Clinical Application of Intravascular Administration of Non-ionic, Low Osmolar Contrast Agent, Ioversol (Optiray 320) and Its Side Effects Comparison with Meglumine Iothalamate(Conray 60). Journal of Korean Radiological Society. 1990; 26(6):1284-90. https://doi.org/10.3348/jkrs.1990.26.6.1284
  13. Dongkook Life Science. 2019. Available from: http://www.dkls.co.kr/product/list.php?type=medicine.
  14. Ministry of Food and Drug Safety. 2017. Available from: https://nedrug.mfds.go.kr/searchDrug?sort=&sortOrder=false&searchYn=true&page=1&searchDivision=detail&itemName=%EC%9D%B4%EC%98%A4%EB%B2%84%EC%86%94&entpName=&ingrName1=&ingrName2=&ingrName3=&itemSeq=&stdrCodeName=&atcCodeName=&indutyClassCode=&sClassNo=&narcoticKindCode=&etcOtcCode=&makeMaterialGb=&searchConEe=AND&eeDocData=&searchConUd=AND&udDocData=&searchConNb=AND&nbDocData=&startPermitDate=&endPermitDate=.
  15. Thomas AMK. Development of diagnostic radiology. In: Thomas AMK, Isherwood I, Wells PNT(Eds.), The invisible light, 100 year of medical radiology. Oxford: Blackwell Science; 1995: 13-8.
  16. Swick M. Radiographic media in urology, the discovery of excretion urography. Surg Clin N Am. 1978;58:977-94. https://doi.org/10.1016/S0039-6109(16)41638-5
  17. Swick M. Darstellung der Niere und Harnwege in Roentgenbild durch intravenose Einbringung eines Kontraststoffes: Des Uroselectans. Klin uanau Wochenschr. 1929;8:2087-9. https://doi.org/10.1007/BF01875121
  18. Von Lichtenberg A, Swick M. Klinische Prufung des Uroselectans. Klin Wochenschr. 1929;8:2089-91. https://doi.org/10.1007/BF01875122
  19. Wallingford VH. The development of organic iodide compounds as X-ray contrast media. J Am Pharm Assoc (Scientific Edition). 1953;42:721-8. https://doi.org/10.1002/jps.3030421206
  20. Almen T. Contrast agent design. Some aspects on the synthesis of water-soluble contrast agents of low osmolality. J Theor Biol. 1969;24:216-26. https://doi.org/10.1016/S0022-5193(69)80047-0
  21. Kim YD. The side effect of contrast media and its related factors in contrast enhanced computed tomography [master's thesis]. Department of public health, Graduate School, Chonnam National University; 2005.
  22. Jung KE, Chung JM, Park BC, Jee KN, Jee YK, Kim MH. A clinical study of cutaneous adverse reactions to nonionic contrast media in Korea. Ann Dermatol. 2012;24(1):22-5. https://doi.org/10.5021/ad.2012.24.1.22
  23. Dyvik K, Dyrstad K, Tronstad A. Relationship between viscosity and determined injection pressure in angio-graphic catheters for common roentgen contrast media. Acta Radiologica Suppl. 1995;36:43-9. https://doi.org/10.1177/0284185195036S39906
  24. Smedby O. Viscosity of some contemporary contrast media before and after mixing with whole blood. Acta Radiol. 1992;33:600-5. https://doi.org/10.3109/02841859209173222