Abstract
This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.
본 연구는 매년 수만 건 발생되는 화재에서 화재확산에 의한 피해 예방과 대응 마련을 위해 공동주택 및 일반건물의 내부화재를 실물화재실험을 통해 재현하였다. 또한, 개구부 크기와 차양길이 조건을 달리하고 이에 따른 외벽온도 분포를 분석하여 화재확산방지 기초자료를 제공하고자 하였다. 실험결과, 차양을 설치하지 않았을 때 최고온도는 약 380℃ 이상으로 나타났다. 차양을 설치하지 않은 최고온도를 기준으로 차양길이가 150mm 일 때, 동일한 측정점에서 약 90℃가량 낮아졌으며, 300mm에서 약 150℃ 이상, 450mm에서 175℃ 이상 온도가 낮아졌으며, 차양길이 600mm 일 때, 최고온도 차는 약 180℃ 이상 낮아지는 것으로 나타나 개구부 상부의 차양 설치가 외벽의 수직화재 확산에 의한 화염온도를 낮추는데 효과가 있는 것으로 판단된다.