DOI QR코드

DOI QR Code

The Determination of the Duration of Electroconvulsive Therapy-Induced Seizure Using Local Standard Deviation of the Electroencephalogram Signal and the Changes of the RR Interval of Electrocardiogram

  • Kim, Eun Young (Mental Health Center, Seoul National University Health Care Center) ;
  • Yoo, Cheol Seung (Department of Psychiatry, Institute of Clinical Psychopharmacology, Dongguk University Ilsan Hospital) ;
  • Jung, Dong Chung (Department of Neuropsychiatry, Seoul National University Hospital) ;
  • Yi, Sang Hoon (Department of Computer Simulation, Institute of Basic Science, Inje University) ;
  • Chung, In-Won (Department of Psychiatry, Institute of Clinical Psychopharmacology, Dongguk University Ilsan Hospital) ;
  • Kim, Yong Sik (Department of Psychiatry, Institute of Clinical Psychopharmacology, Dongguk University Ilsan Hospital) ;
  • Ahn, Yong Min (Department of Neuropsychiatry, Seoul National University Hospital)
  • Received : 2019.08.14
  • Accepted : 2020.02.13
  • Published : 2020.04.30

Abstract

Objectives In electroconvulsive therapy (ECT) research and practice, the precise determination of seizure duration is important in the evaluation of clinical relevance of the ECT-induced seizure. In this study, we have developed computerized algorithms to assess the duration of ECT-induced seizure. Methods Subjects included 5 males and 6 females, with the mean age of 33.1 years. Total 55 ECT sessions were included in the analysis. We analyzed the standard deviation of a finite block of electroencephalography (EEG) data and the change in the local slope of RR intervals in electrocardiography (ECG) signals during ECT-induced seizure. And then, we compared the calculated seizure durations from EEG recording (EEG algorithm) and ECG recording (ECG algorithm) with values determined by consensus of clinicians based on the recorded EEG (EEG consensus), as a gold standard criterion, in order to testify the computational validity of our algorithms. Results The mean seizure durations calculated by each method were not significantly different in sessions with abrupt flattened postictal suppression and in sessions with non-abrupt flattened postictal suppression. The intraclass correlation coefficients (95% confidence interval) of the three methods (EEG algorithm, ECG algorithm, EEG consensus) were significant in the total sessions [0.79 (0.70-0.86)], the abrupt flattened postictal suppression sessions [0.84 (0.74-0.91)], and the non-abrupt flattened postictal suppression sessions [0.67 (0.45-0.84)]. Correlations between three methods were also statistically significant, regardless of abruptness of transition. Conclusions Our proposed algorithms could reliably measure the duration of ECT-induced seizure, even in sessions with non-abrupt transitions to flat postictal suppression, in which it is typically difficult to determine the seizure duration.

Keywords

References

  1. Edwards M, Koopowitz LF, Harvey EJ. A naturalistic study of the measurement of seizure adequacy in electroconvulsive therapy. Aust N Z J Psychiatry 2003;37:312-318. https://doi.org/10.1046/j.1440-1614.2003.01183.x
  2. Mayur P. Ictal electroencephalographic characteristics during electroconvulsive therapy: a review of determination and clinical relevance. J ECT 2006;22:213-217. https://doi.org/10.1097/01.yct.0000235922.14623.39
  3. Benbow SM, Benbow J, Tomenson B. Electroconvulsive therapy clinics in the United Kingdom should routinely monitor electroencephalographic seizures. J ECT 2003;19:217-220. https://doi.org/10.1097/00124509-200312000-00007
  4. Rattehalli RD, Thirthalli J, Rawat V, Gangadhar BN, Adams CE. Measuring electroencephalographic seizure adequacy during electroconvulsive therapy: a comparison of 2 definitions. J ECT 2009;25:243-245. https://doi.org/10.1097/YCT.0b013e3181a09d4d
  5. Sawayama E, Takahashi M, Inoue A, Nakajima K, Kano A, Sawayama T, et al. Moderate hyperventilation prolongs electroencephalogram seizure duration of the first electroconvulsive therapy. J ECT 2008;24:195-198. https://doi.org/10.1097/YCT.0b013e3181620815
  6. Scott AIF. Monitoring electroconvulsive therapy by electroencephalogram: an update for ECT practitioners. Adv Psychiatr Treat 2007;13:298-304. https://doi.org/10.1192/apt.bp.106.002832
  7. Christensen P, Koldbaek IB. EEG monitored ECT. Br J Psychiatry 1982;141:19-23. https://doi.org/10.1192/bjp.141.1.19
  8. Ranganath RD, Jagadisha, Gangadhar BN, Tomar M, Candade VS, Hemalatha KR. ECT and heart rate changes: an alternative to EEG monitoring for seizure confirmation during modified ECT. German J Psychiatry 2003;3:60-63.
  9. Scott AIF, Shering PA, Dykes S. Would monitoring by electroencephalogram improve the practice of electroconvulsive therapy? Br J Psychiatry 1989;154:853-857. https://doi.org/10.1192/bjp.154.6.853
  10. Yoo CS, Jung DC, Ahn YM, Kim YS, Kim SG, Yoon H, et al. Automatic detection of seizure termination during electroconvulsive therapy using sample entropy of the electroencephalogram. Psychiatry Res 2012;195:76-82. https://doi.org/10.1016/j.psychres.2011.06.020
  11. American Psychiatric Association. The Practice of Electroconvulsive Therapy: Recommendations for Treatment, Training and Privileging. 2nd ed. Washington, DC: American Psychiatric Association;2001.
  12. Gilmore JH, Isley MR, Evans DL, Kong LS, Ekstrom D, Kafer ER, et al. The reliability of computer-processed EEG in the determination of ECT seizure duration. Convuls Ther 1991;7:166-174.
  13. Greene BR, Boylan GB, Reilly RB, de Chazal P, Connolly S. Combination of EEG and ECG for improved automatic neonatal seizure detection. Clin Neurophysiol 2007;118:1348-1359. https://doi.org/10.1016/j.clinph.2007.02.015
  14. Guze BH, Liston EH, Baxter LR Jr, Richeimer SH, Gold ME. Poor interrater reliability of MECTA EEG recordings of ECT seizure duration. J Clin Psychiatry 1989;50:140-142.
  15. Ries RK. Poor interrater reliability of MECTA EEG seizure duration measurement during ECT. Biol Psychiatry 1985;20:94-98. https://doi.org/10.1016/0006-3223(85)90140-4
  16. Krystal AD, Weiner RD. ECT seizure duration: reliability of manual and computer-automated determinations. Convuls Ther 1995;11:158-169.
  17. Waite J, Easton A. The ECT Handbook. 3rd ed. London: RCPsych Publications;2013.
  18. Semple DM, Gunn W, Davidson Z, Queirazza F. Teaching therapeutic seizure criteria to psychiatrists. J ECT 2014;30:220-223. https://doi.org/10.1097/YCT.0000000000000087
  19. Eggleston KS, Olin BD, Fisher RS. Ictal tachycardia: the head-heart connection. Seizure 2014;23:496-505. https://doi.org/10.1016/j.seizure.2014.02.012
  20. van Elmpt WJ, Nijsen TM, Griep PA, Arends JB. A model of heart rate changes to detect seizures in severe epilepsy. Seizure 2006;15: 366-375. https://doi.org/10.1016/j.seizure.2006.03.005
  21. Greene BR, de Chazal P, Boylan GB, Connolly S, Reilly RB. Electrocardiogram based neonatal seizure detection. IEEE Trans Biomed Eng 2007;54:673-682. https://doi.org/10.1109/TBME.2006.890137
  22. Larson G, Swartz C, Abrams R. Duration of ECT-induced tachycardia as a measure of seizure length. Am J Psychiatry 1984;141:1269-1271. https://doi.org/10.1176/ajp.141.10.1269
  23. Swartz CM, Manly DT. Endpoint of ECT-induced elevation in heart rate. J ECT 1999;15:125-128.
  24. Osorio I, Manly BF. Probability of detection of clinical seizures using heart rate changes. Seizure 2015;30:120-123. https://doi.org/10.1016/j.seizure.2015.06.007
  25. Scott AIF. The ECT Handbook: the Third Report of the Royal College of Psychiatrists' Special Committee on ECT. 2nd ed. London: Royal College of Psychiatrists;2005.
  26. Mesbah M, Balakrishnan M, Colditz PB, Boashash B. Automatic seizure detection based on the combination of newborn multi-channel EEG and HRV information. EURASIP J Adv Signal Process 2012;2012:215. https://doi.org/10.1186/1687-6180-2012-215
  27. Abrams R. Stimulus titration and ECT dosing. J ECT 2002;18:3-9. https://doi.org/10.1097/00124509-200203000-00002
  28. Beyer JL, Weiner RD, Glenn MD. Electroconvulsive Therapy: a Programmed Text. 2nd ed. Washington, DC: American Psychiatric Press;1998.
  29. Azuma H, Fujita A, Sato K, Arahata K, Otsuki K, Hori M, et al. Postictal cardiovascular response predicts therapeutic efficacy of electroconvulsive therapy for depression. Psychiatry Clin Neurosci 2007;61:290-294. https://doi.org/10.1111/j.1440-1819.2007.01665.x
  30. Kramer BA, Pollock VE, Schneider LS, Gray GE. Interrater reliability of MECTA SR-1 seizure duration. Biol Psychiatry 1989;25:642-644. https://doi.org/10.1016/0006-3223(89)90228-X
  31. Swartz CM, Abrams R, Lane RD, DuBois MA, Srinivasaraghavan J. Heart rate differences between right and left unilateral electroconvulsive therapy. J Neurol Neurosurg Psychiatry 1994;57:97-99. https://doi.org/10.1136/jnnp.57.1.97
  32. Cohen J. Statistical Power Analysis for the Behavioral Sciences. 2nd ed. Hillsdale, NJ: Lawrence Erlbaum Associates;1988.
  33. Bergeron R, Floyd RG, McCormack AC, Farmer WL. The generalizability of externalizing behavior composites and subscale scores across time, rater, and instrument. School Psychol Rev 2008;37:91-108. https://doi.org/10.1080/02796015.2008.12087911
  34. Swartz CM. Heart rate and electroconvulsive therapy. In: Swartz CM, editor. Electroconvulsive and Neuromodulation Therapies. New York, NY: Cambridge University Press;2009. p.477-484.
  35. Bergsholm P, Bleie H, Gran L, d'Elia G. Cardiovascular response and seizure duration as determined by electroencephalography during unilateral electroconvulsive therapy. Acta Psychiatr Scand 1993;88:25-28. https://doi.org/10.1111/j.1600-0447.1993.tb03409.x
  36. Chung KF. Relationships between seizure duration and seizure threshold and stimulus dosage at electroconvulsive therapy: implications for electroconvulsive therapy practice. Psychiatry Clin Neurosci 2002;56:521-526. https://doi.org/10.1046/j.1440-1819.2002.01048.x
  37. Little JD, McFarlane J, Barton D, Varma SL. Australian and US responses to electroconvulsive therapy dosage selection. Aust N Z J Psychiatry 2002;36:629-632. https://doi.org/10.1046/j.1440-1614.2002.01081.x
  38. Rowny SB, Cycowicz YM, McClintock SM, Truesdale MD, Luber B, Lisanby SH. Differential heart rate response to magnetic seizure therapy (MST) relative to electroconvulsive therapy: a nonhuman primate model. Neuroimage 2009;47:1086-1091. https://doi.org/10.1016/j.neuroimage.2009.05.070
  39. Swartz CM. Physiological response to ECT stimulus dose. Psychiatry Res 2000;97:229-235. https://doi.org/10.1016/S0165-1781(00)00234-1
  40. Swartz CM, Manly DT. Efficiency of the stimulus characteristics of ECT. Am J Psychiatry 2000;157:1504-1506. https://doi.org/10.1176/appi.ajp.157.9.1504
  41. Howsepian AA. On describing "seizure length" in electroconvulsive therapy. J ECT 2011;27:93-94. https://doi.org/10.1097/YCT.0b013e3181d7766c