References
- Suzuki Y, Shimpo H, Ohkubo C, Kurtz KS. Fabrication of fixed implant prostheses using function bite impression technique. J Prosthodont Res 2012;56:293-6. https://doi.org/10.1016/j.jpor.2012.02.005
- Meyer FS. The generated path technique in reconstruction dentistry: Part I: Complete dentures. J Prosthet Dent 1959;9:354-66. https://doi.org/10.1016/0022-3913(59)90064-2
- Dawson PE. Functional occlusion: From TMJ to smile design. 1st ed. St. Louis; CV Mosby; 2007. p. 242.
- DuVall NB, Rogers PM. Application of the functionally generated path technique to restore mandibular molars in bilateral group function occlusion. J Prosthodont 2013;22:226-32. https://doi.org/10.1111/j.1532-849X.2012.00944.x
- Jaffe VN. The functionally generated path in full denture construction. J Prosthet Den 1954;4:214-21. https://doi.org/10.1016/0022-3913(54)90099-2
- Re JP, Orthlieb JD. Functionally generated path technique to fabricate a crown in group function on a deciduous maxillary canine. J Prosthet Dent 2019;121:185-6. https://doi.org/10.1016/j.prosdent.2018.01.023
- Kafandaris NM. A modified functionally generated path technique for making maxillary posterior ceramometal restorations. J Prosthet Dent 1981;46:29-31. https://doi.org/10.1016/0022-3913(81)90130-X
- Patil PG, Nimbalkar-Patil SP, Kulkarni RS. Functionally generated pathways to develop occlusal scheme for removable partial denture. J Interdiscip Dent 2015;5:154-7. https://doi.org/10.4103/2229-5194.181380
- Sutton AJ, Sheets DW Jr, Ford DE. Fabrication of a functionally generated, implant-retained fixed partial denture. J Prosthodont 2003;12:260-4. https://doi.org/10.1016/s1059-941x(03)00105-0
- Saafi J, Debbabi I, Alremthi HA, Cherif M. A modified functionally generated path technique (FGP) for making posterior unit metal-ceramic crown. J Oral Dent Sci 2018;2:1-8.
- Shillingburg HT. Fundamentals of fixed prosthodontics. Quintessence Publishing Company; 1997. p. 355-64.
- Ng J, Ruse D, Wyatt C. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 2014;112:555-60. https://doi.org/10.1016/j.prosdent.2013.12.002
- Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11. https://doi.org/10.1038/sj.bdj.2008.350
- Eeckman J, De Boever JA. Clinical accuracy of functionally generated interocclusal registration waxes. J Prosthet Dent 1988;60:549-52. https://doi.org/10.1016/0022-3913(88)90213-2
- Hammad IA, Nourallah H. Simplified procedure for making fixed partial dentures with a functionally generated path. J Prosthet Dent 1996;75:344-5. https://doi.org/10.1016/S0022-3913(96)90498-9
- Minagi S, Tanaka T, Sato T, Matsunaga T. Double-casting method for fixed prosthodontics with functionally generated path. J Prosthet Dent 1998;79:120-4. https://doi.org/10.1016/S0022-3913(98)70203-3
- Ting-Shu S, Jian S. Intraoral digital impression technique: A review. J Prosthodont 2015;24:313-21. https://doi.org/10.1111/jopr.12218
- Boeddinghaus M, Breloer ES, Rehmann P, Wostmann B. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 2015;19:2027-34. https://doi.org/10.1007/s00784-015-1430-7
- Shamseddine L, Mortada R, Rifai K, Chidiac JJ. Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans: A comparative in vitro study. J Prosthet Dent 2017;118:49-54. https://doi.org/10.1016/j.prosdent.2016.10.003
- Fathi HM, Al-Masoody AH, El-Ghezawi N. The accuracy of fit of crowns made from wax patterns produced conventionally (hand formed) and via CAD/CAM technology. Eur J Prosthodont Restor Dent 2016;24:10-7.
- Shamseddine L, Mortada R, Rifai K, Chidiac JJ. Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: An in vitro comparison. J Prosthet Dent 2016;116:242-8. https://doi.org/10.1016/j.prosdent.2015.12.005
- Homsy FR, Ozcan M, Khoury M, Majzoub ZAK. Marginal and internal fit of pressed lithium disilicate inlays fabricated with milling, 3D printing, and conventional technologies. J Prosthet Dent 2018;119:783-90. https://doi.org/10.1016/j.prosdent.2017.07.025
- Vojdani M, Torabi K, Farjood E, Khaledi A. Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD/CAM and conventional wax up techniques. J Dent (Shiraz) 2013;14:118-29.