DOI QR코드

DOI QR Code

Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam With Reinforced End by Steel Plates

단부 보강에 따른 U-플랜지 트러스 보의 구조 내력에 관한 실험 연구

  • Oh, Myoung Ho (Dept. of Architectural Engineering, Mokpo National Univ.) ;
  • Kim, Young Ho (Dept. of Architectural Engineering, Mokpo National Univ.)
  • 오명호 (국립목포대학교 건축공학과) ;
  • 김영호 (국립목포대학교 건축공학과)
  • Received : 2019.11.11
  • Accepted : 2019.11.28
  • Published : 2020.06.15

Abstract

U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study, the details of delayed buckling of lattice members were developed through reinforcement of the end section, in order to improve structural capacity of U-flanged Truss Steel Beam. To verify the effects of these details, the simple beam experiment was conducted. The maximum capacity of all the specimens were determined by the buckling of the lattice. The vertical reinforced details of the ends with steel plates, rather than the details reinforced with steel bars, are confirmed to be a valid method for enhancing the structural capacity of the U-flanged Truss beam. In addition, U-flanged Truss Steel Beam with reinforced endings with steel plates can exhibit sufficient capacity of the lattice buckling by the formulae according to Korean Building Code (KBC, 2016) and Eurocode 3.

Keywords

References

  1. Chae, H. S., Ryoo, J., Chung, K. S., Moon, Y. M., & Cho, S. M., "Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-firder)", Journal of Korean Society of Steel Construction, Vol.22, No.6, pp.533-541, 2010
  2. Bae, K. W., Moon, T. S., & Heo, B. W., "Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate", Journal of Korean Society of Steel Construction, Vol.16, No.2, pp.236-245, 2004
  3. Kim, D. B., Kim, Y. H., Oh, M. H., & Kim, M. H., "Experimental Study on the Flexural Capacity of the Concrete-Filled Composite Beam with Exposed Top Flange", Journal of the Korean Society of Hazard Mitigation, Vol.17, No.4, pp.1-9, 2017, doi: 10.9798/KOSHAM.2017.17.4.1
  4. Lee, M. H., Oh, M. H., Kim, Y. H., Jeong, S., & Kim, M. H., "Experimental Study on the Shear Capacity of Slim AU Composite Beam", Journal of Korean Association for Spatial Structures, Vol.17, No.3, pp.99-105, 2017, doi: 10.9712/KASS.2017.17.3.099
  5. Park, K. S., Heo, B. W., Kwak, M. G., & Bae, K. W., "Experimental Study on the Flexural Behavior of Encased Composite Beams for Residential Buildings", Journal of the Architectural Institute of Korea Structure and Construction, Vol.24, No.12, pp.91-98, 2008
  6. Oh, M. H., Kim, Y. H., Kang, J. Y., & Kim, M. H., "Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam", Journal of Korean Association for Spatial Structures, Vol.18, No.4, pp.113-121, 2018, doi: 10.9712/KASS.2018.18.4.113
  7. Oh, M. H., Kim, Y. H., & Kim, M. H., "Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam", Journal of Korean Association for Spatial Structures, Vol.18, No.4, pp.123-130, 2018, doi: 10.9712/KASS.2018.18.4.123
  8. MOLIT, "Korea Building Code", Ministry of Land, Infrastructure and Transport, 2016.
  9. BS EN 1993-1-1:2005: Eurocode 3, Design of steel structures. Part 1-1 : General rules and rules for buildings", British Standards(BS), 2005.