과제정보
This research was partially supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2019R1F1A1045956).
참고문헌
- W.J. Yoo, H.I. Sim, S.H. Shin, K.W. Jang, S. Cho, J.H. Moon, B. Lee, A fiber-optic sensor using an aqueous solution of sodium chloride to measure temperature and water level simultaneously, Sensors 14 (2014) 18823-18836.
- S. Rizzolo, J. Perisse, A. Boukenter, Y. Ouerdane, E. Marin, J.-R. Mace, M. Cannas, S. Girard, Real time monitoring of water level and temperature in storage fuel pools through optical fibre sensors, Sci. Rep. 7 (2017), https://doi.org/10.1038/s41598-017-08853-7.
- A. Stancalie, F. Esposito, R. Ranjan, P. Bleotu, S. Campopiano, A. Iadicicco, D. Sporea, Arc-induced Long Period Gratings in standard and speciality optical fibers under mixed neutron-gamma irradiation, Sci. Rep. 7 (2017), https://doi.org/10.1038/s41598-017-16225-4.
- P. Ferdinand, S. Magne, G. Laffont, Optical fiber sensors to improve the safety of nuclear power plants, in: Proc. Of the Fourth Asia Pacific Optical Sensors Conference, 2013. Wuhan, China, October 15-18.
- S. Grice, W. Zhanga, K. Sugdena, I. Benniona, Liquid level sensor utilising a long period fiber grating, in: Proc. Of Optical Components and Materials VI, United State, San Jose, CA, 2009. February 4-6.
- S.M. Chandani, N.A.F. Jaeger, Optical fiber-based liquid level sensor, Opt. Eng. 46 (2007), 114401, 1-114401-7.
- J.E. Antonio-Lopez, J.J. Sanchez-Mondragon, P. LikamWa, D.A. May-Arrioja, Fiber-optic sensor for liquid level measurement, Opt. Lett. 36 (2011) 3425-3427.
- C.M. Petrie, J.L. McDuffee, Liquid level sensing for harsh environment applications using distributed fiber optic temperature measurements-heating, Sens. Actuators, A 282 (2018) 114-123.
- C. Yang, S. Chen, G. Yang, Fiber optical liquid level sensor under cryogenic environment, Sens. Actuators, A 94 (2001) 69-75.
- R. Kim, C.H. Park, W.J. Yoo, J.H. Moon, Development and characterization of a fiber-optic monitoring system for the key environment variables of the spent fuel pool at a nuclear power plant, Ann. Nucl. Energy 99 (2017) 183-192.
- C.A.F. Marques, A. Pospori, D. Saez-Rodriguez, K. Nielsen, O. Bang, D.J. Webb, Fiber-optic liquid level monitoring system using microstructured polymer FBG array sensors, in: Proc. Of the 24th International Conference on Optical Fibre Sensors, 2013. Curitiba, Brazil, September 28-October 2.
- C. Teng, H. Liu, H. Deng, S. Deng, H. Yang, R. Xu, M. Chen, L. Yuan, J. Zheng, Liquid level sensor based on a V-Groove structure plastic optical fiber, Sensors 18 (2018), https://doi.org/10.3390/s18093111.
- D. Wang, Y. Zhang, B. Jin, Y. Wang, M. Zhang, Quasi-distributed optical fiber sensor for liquid-level measurement, IEEE Photonics J (2017), https://doi.org/10.1109/JPHOT.2017.2776245.
- H.-K. Lee, J. Choo, G. Shin, A simple all-optical water level monitoring system based on wavelength division multiplexing with an arrayed waveguide grating, Sensors 19 (2019), https://doi.org/10.3390/s19143095.
- C.-B. Kim, C.B. Su, Measurement of the refractive index of liquids at 1.3 and 1.5 micron using a flbre optic Fresnel ratio meter, Meas. Sci. Technol. 15 (2004) 1683-1686.
- K. Yuksel, Optical fiber sensor system for remote and multi-point refractive index measurement, Sens. Actuators, A 250 (2016) 29-34.
- Y.H. Kim, S.J. Park, S.-W. Jeon, S. Ju, C.-S. Park, W.-T. Han, B.H. Lee, Thermo-optic coefficient measurement of liquids based on simultaneous temperature and refractive index sensing capability of a two-mode fiber interferometric probe, Optic Express 20 (2012) 23744-23754.
- S.-R. Moon, H.-K. Lee, C.-H. Lee, Automatic wavelength Allocation method using Rayleigh backscattering for a WDM-PON with tunable lasers, J. Opt. Commun. Netw. 5 (2013) 190-197.
- Industry Guidance for Compliance with NRC Order EA-12-051, "To Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation", NEI 12-02 Rev.1, Nuclear Energy Institute, Washington DC, 2012.
피인용 문헌
- Long-Reach DWDM-Passive Optical Fiber Sensor Network for Water Level Monitoring of Spent Fuel Pool in Nuclear Power Plant vol.20, pp.15, 2020, https://doi.org/10.3390/s20154218
- Multiplexed Passive Optical Fiber Sensor Networks for Water Level Monitoring: A Review vol.20, pp.23, 2020, https://doi.org/10.3390/s20236813
- 16 Ch × 200 GHz DWDM-Passive Optical Fiber Sensor Network Based on a Power Measurement Method for Water-Level Monitoring of the Spent Fuel Pool in a Nuclear Power Plant vol.21, pp.12, 2021, https://doi.org/10.3390/s21124055