참고문헌
- Scolozzi P, Martinez A, Jaques B (2007) Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant. J Craniofac Surg 18(1):224-228
- Tessier P (1982) Autogenous bone grafts taken from the calvarium for facial and cranial applications. Clin Plast Surg 9:531-538
- Al-Ahmari A, Nasr EA, Moiduddin K, Alkindi M, Kamrani A Patient specific mandibular implant for maxillofacial surgery using additive manufacturing. In 2015 International Conference on Industrial Engineering and Operations Management (IEOM) (pp. 1-7). IEEE.
- Giannoudis PV, Dinopoulos H, Tsiridis E (2005) Bone substitutes: an update. Injury 36(3):S20-S27
- Sbordone C, Toti P, Guidetti F, Califano L, Pannone G, Sbordone L (2014) Volumetric changes after sinus augmentation using blocks of autogenous iliac bone or freeze-dried allogeneic bone. a non-randomized study. J Craniomaxillofac Surg 42(2):113-118
- Powell NB, Riley RW (1989) Facial contouring with outer-table calvarial bone: a 4-year experience. Arch Otolaryngol Head Neck Surg 115(12):1454-1458
- Honigmann P, Sharma N, Okolo B, Popp U, Msallem B, Thieringer FM (2018) Patient-specific surgical implants made of 3D printed PEEK: material, technology, and scope of surgical application. BioMed Res Int
- Rana M, Chui CH, Wagner M, Zimmerer R, Rana M, Gellrich NC (2015) Increasing the accuracy of orbital reconstruction with selective laser-melted patient-specific implants combined with intraoperative navigation. J Oral Maxillofac Surg 73(6):1113-1118
- Kim MM, Boahene KD, Byrne PJ (2009) Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects. Arch Facial Plast Surg 11(1):53-57
- Owusu JA, Boahene K (2015) Update of patient-specific maxillofacial implant. Curr Opin Otolaryngol Head Neck Surg 23(4):261-264
- Binder WJ, Kaye A (1994) Reconstruction of posttraumatic and congenital facial deformities with three-dimensional computer-assisted custom designed implants. Plast Reconstr Surg 94(6):775-785
- Jarvinen S, Suojanen J, Kormi E, Wilkman T, Kiukkonen A, Leikola J, Stoor P (2019) The use of patient specific polyetheretherketone implants for reconstruction of maxillofacial deformities. J Craniomaxillofac Surg 47(7): 1072-1076
- Kurtz SM (2012) An overview of PEEK biomaterials. In: PEEK biomaterials handbook. William Andrew Publishing:1
- Nieminen T, Kallela I, Wuolijoki E, Kainulainen H, Hiidenheimo I, Rantala I (2008) Amorphous and crystalline polyetheretherketone: mechanical properties and tissue reactions during a 3-year follow-up. J Biomed Mater Res A 84(2):377-383
- Scolozzi P (2012) Maxillofacial reconstruction using polyetheretherketone patient-specific implants by "mirroring" computational planning. Aesthet Plast Surg 36(3):660-665
- Alonso-Rodriguez E, Cebrian JL, Nieto MJ, Del Castillo JL, Hernandez-Godoy J, Burgueno M (2015) Polyetheretherketone custom-made implants for craniofacial defects: report of 14 cases and review of the literature. J Craniomaxillofac Surg 43(7):1232-1238
- Rosenthal G, Ng I, Moscovici S, Lee KK, Lay T, Martin C, Manley GT (2014) Polyetheretherketone implants for the repair of large cranial defects: a 3-center experience. Neurosurgery 75(5):523-529
피인용 문헌
- Quality Characteristics and Clinical Relevance of In-House 3D-Printed Customized Polyetheretherketone (PEEK) Implants for Craniofacial Reconstruction vol.9, pp.9, 2020, https://doi.org/10.3390/jcm9092818
- Patient-Specific Surgical Implant Using Cavity-Filled Approach for Precise and Functional Mandible Reconstruction vol.10, pp.17, 2020, https://doi.org/10.3390/app10176030
- Quantitative Assessment of Point-of-Care 3D-Printed Patient-Specific Polyetheretherketone (PEEK) Cranial Implants vol.22, pp.16, 2020, https://doi.org/10.3390/ijms22168521
- A Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction vol.10, pp.16, 2020, https://doi.org/10.3390/jcm10163563
- Bone Regeneration of a 3D-Printed Alloplastic and Particulate Xenogenic Graft with rhBMP-2 vol.22, pp.22, 2020, https://doi.org/10.3390/ijms222212518
- Biomechanical comparison of locking and non-locking patient-specific mandibular reconstruction plate using finite element analysis vol.124, 2020, https://doi.org/10.1016/j.jmbbm.2021.104849