Abstract
This study analyzed the fire intensity according to the zones classification between traditional market stores using FDS software. Modeling was conducted for the Seomoon traditional market district 4 at Daegu, which places combustibles, such as textiles and clothing near the passageway. The first ignition point assumed a short circuit fire situation at the fourth store combustible. The analysis was conducted under similar conditions as the fire situation in 2016. When there was no section wall, the fire spread rapidly through radiation in all directions from the fire-origin point. After 600 seconds, the mall was burnt to the ground. When section walls were present, however, the fire could be restricted inside the compartment. The first intensity of the two analysis conditions was predicted from the total heat energy from 200 seconds (X1) to 600 seconds (X2), where the heat generation rate began to increase rapidly. As a result of installing section walls near the fire point, heat energy generation of approximately 11.12 MW (55.68 %) was delayed. Further analysis of smoke control, according to the section wall arrangement and re-installation facilities, will be needed to study the characteristics of fire in traditional markets comprehensively.
본 연구에서는 화재시뮬레이션을 이용하여 전통재래시장 상가 간 내연성 구획 벽 설치에 따른 화재강도 분석을 실시하였다. 대구 서문시장 4지구 상가 일부분을 대상으로 모델링을 실시하였으며 섬유, 의류와 같은 가연물을 통로 인근에 배치하여 2016년 화재발생 당시와 유사한 조건으로 해석을 진행하였다. 최초발화지점은 4번째 상가 적치물에서 전기합선에 의해 발생한 것으로 가정하였다. 구획 벽이 없는 경우 최초발화지점에서 방사형태로 급속도로 화재가 전파되며, 600초 이후 30 ㎡의 상가를 전소시켰다. 상가간 구획 벽을 설정한 경우 화재저항으로 인해 화재의 확산을 구획지역내부로 한정시킬 수 있었다. 열발생율이 급격히 상승하기 시작하는 200초(X1)에서 600초(X2)까지 총 발생한 열에너지를 통해 두 해석조건의 화재강도를 예측하였다. 결과적으로 본 연구에서 설정한 발화지점 인근의 구획 벽 설정을 통하여 해석한 결과 약 11.12 MW(55.68 %)의 열에너지 발생을 지연시킴을 확인하였다. 추후 구획 벽의 배치 및 재연설비 설치에 따른 연기제어에 대한 추가 해석을 수행함으로서 전통재래시장에서의 종합적인 화재특성 연구가 필요할 것으로 생각된다.