참고문헌
- Audran M, Kumar R. The physiology and pathophysiology of vitamin D. Mayo Clin Proc. 1985;60:851-866. http://doi.org/10.1016/s0025-6196(12)64791-0
- Norman AW. From vitamin D to hormone D: fundamentals of the vitamin D endocrine system essential for good health. Am J Clin Nutr. 2008;88:491-499. http://doi.org/10.1093/ajcn/88.2.491S
- Holick MF. Vitamin D status: measurement, interpretation and clinical application. Ann Epidemiol. 2009;19:73-78. http://doi.org/10.1016/j.annepidem.2007.12.001
- Dawson-Hughes B, Heaney RP, Holick MF, Lips P, Meunier PJ, Vieth R. Estimates of optimal vitamin D status. Osteoporos Int. 2005;16:713-716. http://doi.org/10.1007/s00198-005-1867-7
- Lavie CJ, Dinicolantonio JJ, Milani RV, O'Keefe JH. Vitamin D and cardiovascular health. Circulation. 2013;128:2404-2406. http://doi.org/10.1161/CIRCULATIONAHA.113.002902
- Holick MF. Sunlight and vitamin D for bone health and prevention of autoimmune diseases, cancers, and cardiovascular disease. Am J Clin Nutr. 2004;80:1678s-1688s. http://doi.org/10.1093/ajcn/80.6.1678S
- Mathieu C, Badenhoop K. Vitamin D and type 1 diabetes mellitus: state of the art. Trends Endocrinol Metab, 2005;16:261-266. http://doi.org/10.1016/j.tem.2005.06.004
- Dawson-Hughes B, Mithal A, Bonjour JP, Boonen S, Burckhardt P, Fuleihan GE, et al. IOF position statement: vitamin D recommendations for older adults. Osteoporos Int. 2010;21:1151-1154. http://doi.org/10.1007/s00198-010-1285-3
- Holick MF, Binkley NC, Bischoff-Ferrari HA, Gordon CM, Hanley DA, Heaney RP, et al. Evaluation, treatment, and prevention of vitamin D deficiency: an Endocrine Society clinical practice guideline. J Clin Endocrinol Metab. 2011;96:1911-1930. http://doi.org/10.1210/jc.2011-0385
- Woloszynska-Read A, Johnson CS, Trump DL. Vitamin D and cancer: clinical aspects. Best Pract Res Clin Endocrinol Metab. 2011;25:605-615. http://doi.org/10.1016/j.beem.2011.06.006
- Shimada K, Mitamura K, Higashi T. Gas chromatography and high performance liquid chromatography of natural steroids. J Chromatogr A. 2001;935:141-172. http://doi.org/10.1016/s0021-9673(01)00943-8
- Lee J, Vasikaran S. Current recommendations for laboratory testing and use of bone turnover markers in management of osteoporosis. Ann Lab Med. 2012;32:105-112. http://doi.org/10.3343/alm.2012.32.2.105
- Binkley N, Krueger D, Cowgill CS, Plum L, Lake E, Hansen KE, et al. Assay variation confounds the diagnosis of hypovitaminosis D: a call for standardization. J Clin Endocrinol Metab. 2004;89: 3152-3157. http://doi.org/10.1210/jc.2003-031979
- Roth HJ, Schmidt-Gayk H, Weber H, Niederau C. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference. Ann Clin Biochem. 2008;45:153-159. http://doi.org/10.1258/acb.2007.007091
- Glendenning P, Taranto M, Noble JM, Musk AA, Hammond C, Goldswain PR, et al. Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite- specific assays. Ann Clin Biochem. 2006;43:23-30. http://doi.org/10.1258/000456306775141650
- Westgard JO, Westgard SA. The quality of laboratory testing today: an assessment of sigma metrics for analytic quality using performance data from proficiency testing surveys and the CLIA criteria for acceptable performance. Am J Clin Pathol. 2006;125: 343-354. https://doi.org/10.1309/V50H4FRVVWX12C79
- Milinkovic N, Ignjatovic S, Sumarac Z, Majkic-Singh N. Uncertainty of measurement in laboratory medicine. J Med Biochem. 2018; 37:279-288. http://doi.org/10.2478/jomb-2018-0002
- Chemistry Resource Committee. ABVD Participant Summary [Internet]. Northfield, IL: College of American Pathologists; 2013 [cited by 2020 Feb 19]. Available from: https://www.cap.org/member-resources/councils-committees/accuracy-based-testing-committee-participant-summary-report-discussions
- Westgard JO, editor. Basic method validation. 2nd ed. Madison: Westgard QC Inc.; 2003.
- Nar R, Emekli DI. The evaluation of analytical performance of immunoassay tests by using six-sigma method. J Med Biochem. 2017;36:301-308. http://doi.org/10.1515/jomb-2017-0026
- Erdman P, Palmer-Toy DE, Horowitz G, Hoofnagle A. Accuracybased vitamin D survey: six years of quality improvement guided by proficiency testing. Arch Pathol Lab Med. 2019;143:1531-1538. https://doi.org/10.5858/arpa.2018-0625-CP
- Lind C, Chen J, Byrjalsen I. Enzyme immunoassay for measuring 25-hydroxyvitamin D3 in serum. Clin Chem. 1997;43:943-949. https://doi.org/10.1093/clinchem/43.6.943
- Schleicher RL, Encisco SE, Chaudhary-Webb M, Paliakov E, McCoy LF, Pfeiffer CM. Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. Clin Chim Acta. 2011;412:1594-1599. http://doi.org/10.1016/j.cca.2011.05.010
- Chen H, McCoy LF, Schleicher RL, Pfeiffer CM. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method. Clin Chim Acta. 2008;391:6-12. http://doi.org/10.1016/j.cca.2008.01.017
- Maunsell Z, Wright DJ, Rainbow SJ. Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3. Clin Chem. 2005;51:1683-1690. http://doi.org/10.1373/ clinchem.2005.052936
- Kushnir MM, Ray JA, Rockwood AL, Roberts WL, La'ulu SL, Whittington JE, et al. Rapid analysis of 25-hydroxyvitamin D(2) and D(3) by liquid chromatography-tandem mass spectrometry and association of vitamin D and parathyroid hormone concentrations in healthy adults. Am J Clin Pathol. 2010;134:148-156. http://doi.org/10.1309/AJCPPIA7DFBT4GKS
- Saenger AK, Laha TJ, Bremner DE, Sadrzadeh SM. Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency. Am J Clin Pathol. 2006;125:914-920. http://doi.org/10.1309/J32U-F7GT-QPWN-25AP
- Vogeser M. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry. J Steroid Biochem Mol Biol. 2010;121:565-573. http://doi.org/10.1016/j.jsbmb.2010.02.025
- Hojskov CS, Heickendorff L, Moller HJ. High-throughput liquid-liquid extraction and LCMSMS assay for determination of circulating 25(OH) vitamin D3 and D2 in the routine clinical laboratory. Clin Chim Acta. 2010;411:114-116. http://doi.org/10.1016/j.cca.2009.10.010
- Armas LA, Hollis BW, Heaney RP. Vitamin D2 is much less effective than vitamin D3 in humans. J Clin Endocrinol Metab. 2004;89:5387-5391. http://doi.org/10.1210/jc.2004-0360
- Houghton LA , Vieth R. The case against ergocalciferol (vitamin D2) as a vitamin supplement. Am J Clin Nutr. 2006;84:694-697. http://doi.org/10.1093/ajcn/84.4.694
- Hollis B. Assessment and interpretation of circulating 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D in the clinical environment. Endocrinol Metab Clin North Am. 2010;39:271-287. http://doi.org/10.1016/j.ecl.2010.02.012
- Saleh L, Mueller D, von Eckardstein A. Analytical and clinical performance of the new Fujirebio 25‐OH vitamin D assay, a comparison with liquid chromatography‐tandem mass spectrometry (LCMS/ MS) and three other automated assays. Clin Chem Lab Med CCLM FESCC. 2016;54:617‐625. https://doi.org/10.1515/cclm-2015-0427
- Wyness SP, Straseski JA. Performance characteristics of six automated 25‐hydroxyvitamin D assays: Mind your 3s and 2s. Clin Biochem. 2015;48:1089‐1096. https://doi.org/10.1016/j.clinbiochem. 2015.08.005
- Farrell CJ, Martin S, McWhinney B, Straub I, Williams P, Herrmann M. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods. Clin Chem. 2012;58:531-542. https://doi.org/10.1373/clinchem.2011.172155
- Janssen MJ, Wielders JP, Bekker CC, Boesten LS, Buijs MM, Heijboer AC, et al. Multicenter comparison study of current methods to measure 25-hydroxy-vitamin D in serum. Steroids. 2012;77:1366-1372. https://doi.org/10.1016/j.steroids.2012.07.013